DBDaniel Bauer

Daniel Bauer

*This is an algorithmically generated author record based on publicly available information.

Daniel Bauer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Trends in dc Microgrids: From the control and protection perspective

    by Ali Bidram, Matthew J. Reno, Seyyed Ali Ghorashi Khalil Abadi, Miguel Jimenez Aparicio, Daniel Bauer

    Microgrids (MGs) are driving us toward more resilient power grids. They can operate independently from the upstream power grids and provide a reliable source of power to their customers. Conventionally, ac MGs have been deployed to increase the reliability and resilience of power grids or provide power to remote areas where connection to an electric power grid is not possible. However, more recently, dc MGs have gained much attention due to a number of advantages. These advantages include a higher efficiency and power transfer ratio compared to their ac counterparts as well as simpler control and operation since, in dc systems, only voltage and power are the control objectives; the reactive power and frequency of ac systems are not of concern anymore. However, the dc MG still faces some control challenges, especially from the perspective of voltage regulation and power sharing. Moreover, the protection of dc MGs is more challenging than that of ac ones.


  • Protection Scheme for Fast Detection and Interruption of High-Impedance Faults on Rate-Limited DC Distribution Networks

    by Andrew S. Wunderlich, Daniel Bauer, Enrico Santi, Roger A. Dougal, Andrea Benigni, Rob Bennett, Luis E. Zubieta

    This paper presents a protection scheme for DC power distribution systems based on a unique rate-limited operating mode. The concept of this protection scheme is that extremely slow ramp-rate limits can be imposed on the DC network voltage and on all currents drawn from the network through control of the power electronic interfaces. Meanwhile, all fast transients produced by loads and DGs can be absorbed by local energy storage—typically a battery—behind the interface converter. The removal of all transients from the distribution network enables a very effective method to differentiate normal operation from fault conditions, including high-impedance faults such as vegetation faults and human-body faults. In the proposed scheme, the ramprates of the current and voltage on the network are sensed by each interfaced converter to check for compliance with the defined rate limits. It is unlikely that a given fault on the network will comply with the stringently slow rate limits, so this scheme allows the system to quickly detect the fault and deploy suitable protections. Experimental results show that the presented protection scheme is capable of detecting and interrupting a human-body-impedance fault quickly enough to prevent electrocution on a DC distribution cable operating at voltages of 1000 V and above, leading to unprecedented safety on a power distribution network of this voltage level.