  • Carbon ion beam dosimetry in magnetic fields using Farmer-type ionization chambers of different radii: measurements and simulations

    by S Surla, M Marot, L Burigo, S Brons, A Runz, C P Karger

    Objective. To investigate magnetic field effects on the dose distribution and ionization chambers response in carbon ion reference fields and determine magnetic field correction factors for chambers of different volumes. Approach. The response of six Farmer-type chambers with varying radii (1–6 mm, termed as R1–R6) was measured in magnetic fields up to 1 T in 0.1 T increments using an experimental electromagnet and compared with Monte Carlo simulations. Chamber readings were measured in the entrance region of a monoenergetic carbon ion beam of 390.75 MeV u−1. A lower energy of 200.28 MeV u−1 was applied to chamber R3 for comparison. Polarity and recombination corrections were investigated for the R3 chamber. The local dose change induced by the magnetic field was calculated by Monte Carlo, which together with change of the chamber’s response, was used to calculate the final magnetic field correction factors. Main results. The dependence of the chamber response on the magnetic field was non-linear and volume-dependent. Maximum changes ranged from 0.30% (R4) to 0.62% (R5) at 0.2 T. For R3, the response for the lower energy was systematically decreased by 0.2% in the range of 0.2 T to 0.7 T. No significant effect of the magnetic field on polarity and ion recombination correction was found. The maximum variation of the local dose was found to be (0.03 ± 0.08) % at 0.2 T for beam energy of 390.75 MeV u−1. Magnetic field correction factors for the different chambers ranged from 0.28% (R4) to 0.60% (R5). Significance. This study provides the first detailed analysis of chambers’ response to magnetic flux densities of up to 1 T using chambers of different radii and comparison with simulations. By combining the chamber response alterations with local dose changes magnetic field correction factors were calculated for all six chambers, including the commercial Farmer-type chamber.


  • Monte Carlo simulation for proton dosimetry in magnetic fields: Fano test and magnetic field correction factors k B for Farmer-type ionization chambers

    by M Marot, F Jäger, S Greilich, C P Karger, O Jäkel, L N Burigo

    Objective . In this contribution we present a special Fano test for charged particles in presence of magnetic fields in the MC code TOol for PArticle Simulation (TOPAS), as well as the determination of magnetic field correction factors k B for Farmer-type ionization chambers using proton beams. Approach . Customized C++ extensions for TOPAS were implemented to model the special Fano tests in presence of magnetic fields for electrons and protons. The Geant4-specific transport parameters, DRoverR and finalRange, were investigated to optimize passing rate and computation time. The k B was determined for the Farmer-type PTW 30013 ionization chamber, and 5 custom built ionization chambers with same geometry but varying inner radius, testing magnetic flux density ranging from 0 to 1.0 T and two proton beam energies of 157.43 and 221.05 MeV. Main results . Using the investigated parameters, TOPAS passed the Fano test within 0.39 ± 0.15% and 0.82 ± 0.42%, respectively for electrons and protons. The chamber response ( k B,M,Q ) gives a maximum at different magnetic flux densities depending of the chamber size, 1.0043 at 1.0 T for the smallest chamber and 1.0051 at 0.2 T for the largest chamber. The local dose difference c B remained ≤ 0.1% for both tested energies. The magnetic field correction factor k B , for the chamber PTW 30013, varied from 0.9946 to 1.0036 for both tested energies. Significance . The developed extension for the special Fano test in TOPAS MC code with the adjusted transport parameters, can accurately transport electron and proton particles in magnetic field. This makes TOPAS a valuable tool for the determination of k B . The ionization chambers we tested showed that k B remains small (≤0.72%). To the best of our knowledge, this is the first calculations of k B for proton beams. This work represents a significant step forward in the development of MRgPT and protocols for proton dosimetry in presence of magnetic field.


  • Open Access

    Proton beam dosimetry in the presence of magnetic fields using Farmer‐type ionization chambers of different radii

    by Mathieu Marot, Sonja Surla, Elisa Burke, Stephan Brons, Armin Runz, Steffen Greilich, Christian P. Karger, Oliver Jäkel, Lucas N. Burigo

    Background: Magnetic resonance‐guided proton therapy is promising, as it combines high‐contrast imaging of soft tissue with highly conformal dose delivery. However, proton dosimetry in magnetic fields using ionization chambers is challenging since the dose distribution as well as the detector response are perturbed.Purpose: This work investigates the effect of the magnetic field on the ionization chamber response, and on the polarity and ion recombination correction factors, which are essential for the implementation of a proton beam dosimetry protocol in the presence of magnetic fields.Methods: Three Farmer‐type cylindrical ionization chambers, the 30013 with 3 mm inner radius (PTW, Freiburg, Germany) and two custom built chambers “R1” and “R6” with 1 and 6 mm inner radii respectively were placed at the center of an experimental electromagnet (Schwarzbeck Mess – Elektronik, Germany) 2 cm depth of an in‐house developed 3D printed water phantom. The detector response was measured for a 3 × 10 cm2 field of mono‐energetic protons 221.05 MeV/u for the three chambers, and with an additional proton beam of 157.43 MeV/u for the chamber PTW 30013. The magnetic flux density was varied between 0.1 and 1.0 Tesla in steps of 0.1 Tesla.Results: At both energies, the ionization chamber PTW 30013 showed a non‐linear response as a function of the magnetic field strength, with a decrease of the ionization chamber response of up to 0.27% ± 0.06% (1 SD) at 0.2 Tesla, followed by a smaller effect at higher magnetic field strength. For the chamber R1, the response decreased slightly with the magnetic field strength up to 0.45% ± 0.12% at 1 Tesla, and for the chamber R6, the response decreased up to 0.54% ± 0.13% at 0.1 Tesla, followed by a plateau up to 0.3 Tesla, and a weaker effect at higher magnetic field strength. The dependence of the polarity and recombination correction factor on the magnetic field was ⩽0.1% for the chamber PTW 30013.Conclusions: The magnetic field has a small but significant effect on the chamber response in the low magnetic field region for the chamber PTW 30013 and for R6, and in the high magnetic field region for the chamber R1. Corrections may be necessary for ionization chamber measurements, depending on both the chamber volume and the magnetic flux density. No significant effect of the magnetic field on the polarity and recombination correction factor was detected in this work for the ionization chamber PTW 30013.


  • Open Access

    Technical Note: On the feasibility of performing dosimetry in target and organ at risk using polymer dosimetry gel and thermoluminescence detectors in an anthropomorphic, deformable, and multimodal pelvis phantom

    by Mathieu Marot, Alina Elter, Philipp Mann, Andrea Schwahofer, Clemens Lang, Wibke Johnen, Stefan A. Körber, Bettina Beuthien‐Baumann, Clarissa Gillmann

    Objective To assess the feasibility of performing dose measurements in the target (prostate) and an adjacent organ at risk (rectum) using polymer dosimetry gel and thermoluminescence detectors (TLDs) in an anthropomorphic, deformable and multimodal pelvis phantom (ADAM PETer). Methods The 3D printed prostate organ surrogate of the ADAM PETer phantom was filled with polymer dosimetry gel. Nine TLD600 (LiF:Mg,Ti) were installed in 3x3 rows on a specifically designed 3D-printed TLD holder. The TLD holder was inserted into the rectum at the level of the prostate and fixed by a partially inflated endorectal balloon. Computed tomography (CT) images were taken and treatment planning was performed. A prescribed dose of 4.5 Gy was delivered to the planning target volume (PTV). The doses measured by the dosimetry gel in the prostate and the TLDs in the rectum (“measured dose”) were compared to the doses calculated by the treatment planning system (“planned dose”) on a voxel-by-voxel basis. Results In the prostate organ surrogate, the 3D-γ-index was 97.7% for the 3% dose difference and 3 mm distance to agreement criterium. In the center of the prostate organ surrogate, measured and planned doses showed only minor deviations (<0.1 Gy, corresponding to a percentage error of 2.22%). On the edges of the prostate, slight differences between planned and measured doses were detected with a maximum deviation of 0.24 Gy, corresponding to 5.3% of the prescribed dose. The difference between planned and measured doses in the TLDs was on average 0.08 Gy (range: 0.02-0.21 Gy), corresponding to 1.78% of the prescribed dose (range: 0.44-4.67%). Conclusions The present study demonstrates the feasibility of using polymer dosimetry gel and TLDs for 3D and 1D dose measurements in the prostate and the rectum organ surrogates in an anthropomorphic, deformable and multimodal phantom. The described methodology might offer new perspectives for end-to-end tests in image-guided adaptive radiotherapy workflows.