Jan Hecko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan Hecko has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Fabien Jaulmes
Institute of Plasma Physics of the Czech Academy of Sciences
3 shared publications - Martin Hron
Czech Academy of Sciences - Institute of Plasma Physics Prague, CZECH REPUBLIC
3 shared publications - Michael Komm
Institute of Plasma Physics of the CAS
3 shared publications - Ales Havranek
Czech Academy of Sciences - Institute of Plasma Physics
2 shared publications - Jiri Adamek
Institute of Plasma Physics of the CAS, Za Slovankou 3, 182 00 Prague 8, Czech Republic
2 shared publications - Josef Havlicek
Institute of Plasma Physics AS CR
2 shared publications
Latest Publications
- Open Access
- 18 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (7)
Numerical modelling and optimization of vacuum field during plasma initiation in view of the operation of the COMPASS Upgrade tokamak
The COMPASS Upgrade tokamak will have dimensions R0 = 0.894 m and a ∼ 0.27 m with high-field (Bt ∼ 5 T), high-current (Ip ∼ 2 MA), high-triangularity (δ ∼ 0.4–0.6) capabilities. This contribution aims at establishing open loop circuits currents scenarios for complete plasma initiation (breakdown and burn-through) and initial current ramp-up in both low field (2.5 T) and high field (5 T) conditions. A complete electro-magnetic model of the future device was derived and linearized through the FIESTA code : in particular the Passive Stabilizing Plates have been consistently included. The optimization algorithm aims at providing the currents necessary to generate the proper vacuum field and maintain the plasma in its initial position against the inner limiter. It relies on the YFactory optimization tool. We present for the first time a fully optimized plasma initiation strategy that provides the feed-forward currents of all the coils from breakdown to the ∼ 150 kA mark, without any active feedback. The optimization takes into account a certain number of control points for the field and flux values which allows to guide the null size and shape, as well as ensures initial radial and vertical stability. The breakdown strategy is discussed with respect to the null geometry and the maximum loop voltage requested during the breakdown. The outputs of the optimization are tested via the DYON code for a reasonable range of neutral prefill densities. The duration of burn-through is analysed and an optimum breakdown configuration is identified that minimizes burn-through time, current consumption and stresses. The optimization is further refined in order to minimize the stress in the sliding joint of the Toroidal Field coil which is evaluated by ANSYS APDL model. The combined approach provides an operational space for COMPASS-U startup that is consistent with both electromagnetic and structural constraints.
- 18 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (7)
Open AccessNumerical modelling and optimization of vacuum field during plasma initiation in view of the operation of the COMPASS Upgrade tokamak
The COMPASS Upgrade tokamak will have dimensions R0 = 0.894 m and a ∼ 0.27 m with high-field (Bt ∼ 5 T), high-current (Ip ∼ 2 MA), high-triangularity (δ ∼ 0.4–0.6) capabilities. This contribution aims at establishing open loop circuits currents scenarios for complete plasma initiation (breakdown and burn-through) and initial current ramp-up in both low field (2.5 T) and high field (5 T) conditions. A complete electro-magnetic model of the future device was derived and linearized through the FIESTA code : in particular the Passive Stabilizing Plates have been consistently included. The optimization algorithm aims at providing the currents necessary to generate the proper vacuum field and maintain the plasma in its initial position against the inner limiter. It relies on the YFactory optimization tool. We present for the first time a fully optimized plasma initiation strategy that provides the feed-forward currents of all the coils from breakdown to the ∼ 150 kA mark, without any active feedback. The optimization takes into account a certain number of control points for the field and flux values which allows to guide the null size and shape, as well as ensures initial radial and vertical stability. The breakdown strategy is discussed with respect to the null geometry and the maximum loop voltage requested during the breakdown. The outputs of the optimization are tested via the DYON code for a reasonable range of neutral prefill densities. The duration of burn-through is analysed and an optimum breakdown configuration is identified that minimizes burn-through time, current consumption and stresses. The optimization is further refined in order to minimize the stress in the sliding joint of the Toroidal Field coil which is evaluated by ANSYS APDL model. The combined approach provides an operational space for COMPASS-U startup that is consistent with both electromagnetic and structural constraints.
- Open Access
- 10 June 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (6) , 065030
Physics drivers for the plasma-facing component design of the COMPASS-U tokamak
The main drivers for the metallic plasma-facing component (PFC) design of the COMPASS Upgrade (COMPASS-U) tokamak (B T ⩽5 T, I P ⩽ 2 MA, R geo = 0.9 m, a geo = 0.27 m, t flattop ⩽ 3 s) derived from physics considerations are presented in this paper. Requirements on the plasma-wall gaps are given based on previous experimental observations in other devices. Gaps at the inner/outer midplane are set to minimum values 20 and 40 mm, respectively, to allow all magnetic equilibria in the lower and upper single-null configurations to fit in the PFC outline, to allow an efficient flow in the scrape-off layer towards the divertor and to minimize the impurity flux from the wall. The closed tungsten divertor was designed with a similar shape to ITER’s divertor since COMPASS-U has a similar aspect ratio and uses an ITER-like equilibrium for its baseline scenario. Steady-state thermal loads are calculated at the outer strike-point, where they are expected to be the highest, in attached conditions using a 0D energy balance (⩾150 MW m−2) and in detached conditions using BIT1 kinetic calculations (∼70 MW m−2). Transient thermal loads range from 1.2 MJ m−2 for ELMs (maximum parallel peak energy fluence at targets) to 0.6–1.2 GW m−2 in ∼0.5 ms for high-energy vertical displacement events (maximum perpendicular heat flux density). Electromagnetic loads are calculated during disruptions using an in-house parametric model, accounting for current quench (CQ) and halo current contributions and validated by simulations using the CarMa0NL code, which is able to describe the nonlinear evolution of axisymmetric plasmas in the presence of 3D volumetric structures. The CQ rate is expected to be at least δI P/δt = 3 MA ms−1, and the halo current magnitude is set to 75% of the pre-disruptive maximum plasma current, according to the ITPA disruption database, yielding I halo = 1.5 MA. Maximum total force acts on the bottom divertor baffle with a value of ∼60 kN and the corresponding total torque is ∼4 kN m.
- 10 June 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (6) , 065030
Open AccessPhysics drivers for the plasma-facing component design of the COMPASS-U tokamak
The main drivers for the metallic plasma-facing component (PFC) design of the COMPASS Upgrade (COMPASS-U) tokamak (B T ⩽5 T, I P ⩽ 2 MA, R geo = 0.9 m, a geo = 0.27 m, t flattop ⩽ 3 s) derived from physics considerations are presented in this paper. Requirements on the plasma-wall gaps are given based on previous experimental observations in other devices. Gaps at the inner/outer midplane are set to minimum values 20 and 40 mm, respectively, to allow all magnetic equilibria in the lower and upper single-null configurations to fit in the PFC outline, to allow an efficient flow in the scrape-off layer towards the divertor and to minimize the impurity flux from the wall. The closed tungsten divertor was designed with a similar shape to ITER’s divertor since COMPASS-U has a similar aspect ratio and uses an ITER-like equilibrium for its baseline scenario. Steady-state thermal loads are calculated at the outer strike-point, where they are expected to be the highest, in attached conditions using a 0D energy balance (⩾150 MW m−2) and in detached conditions using BIT1 kinetic calculations (∼70 MW m−2). Transient thermal loads range from 1.2 MJ m−2 for ELMs (maximum parallel peak energy fluence at targets) to 0.6–1.2 GW m−2 in ∼0.5 ms for high-energy vertical displacement events (maximum perpendicular heat flux density). Electromagnetic loads are calculated during disruptions using an in-house parametric model, accounting for current quench (CQ) and halo current contributions and validated by simulations using the CarMa0NL code, which is able to describe the nonlinear evolution of axisymmetric plasmas in the presence of 3D volumetric structures. The CQ rate is expected to be at least δI P/δt = 3 MA ms−1, and the halo current magnitude is set to 75% of the pre-disruptive maximum plasma current, according to the ITPA disruption database, yielding I halo = 1.5 MA. Maximum total force acts on the bottom divertor baffle with a value of ∼60 kN and the corresponding total torque is ∼4 kN m.
- Open Access
- 11 December 2023
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 66 (1) , 015013
Experimental evidence of very short power decay lengths in H-mode discharges in the COMPASS tokamak
Analysis of heat fluxes in scrape-off layer (SOL) plasma is important for the prediction of divertor tile heat loads in future reactor-sized tokamak machines. Typically, the radial heat flux profile can be accurately characterized by the decay length parameter λ q . The predictions are then based on the dependence of λ q on plasma and machine parameters. In recent years, several empirical scaling models were derived from a collective database of decay lengths observed in several large tokamaks as well as two spherical tokamaks. Most recently, a report from the TCV tokamak showed a deviation from several of the proposed models (Maurizio et al (TCV team) 2021 Nucl. Fusion 61 024003). In this work, ∼ 100 edge plasma profiles of ELMy H-mode discharges were collected from the COMPASS tokamak database for heat flux analysis. The COMPASS tokamak has a similar machine size and plasma parameters to the TCV tokamak, offering a valuable comparison. The λ q was measured in both downstream and upstream SOL utilizing a divertor probe array validated by an IR camera and Thomson scattering diagnostics. A comparison with the predictions of several scaling models indicated an occurrence of anomalously short (by a factor of 2–5) inter-ELM power decay lengths in both upstream and downstream, as well as a difference in λ q between these two regions. Possible causes related to the accuracy of magnetic reconstruction were eliminated and physics-based sources of apparent compression effects were hypothesized as a motivation for future research.
- 11 December 2023
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 66 (1) , 015013
Open AccessExperimental evidence of very short power decay lengths in H-mode discharges in the COMPASS tokamak
Analysis of heat fluxes in scrape-off layer (SOL) plasma is important for the prediction of divertor tile heat loads in future reactor-sized tokamak machines. Typically, the radial heat flux profile can be accurately characterized by the decay length parameter λ q . The predictions are then based on the dependence of λ q on plasma and machine parameters. In recent years, several empirical scaling models were derived from a collective database of decay lengths observed in several large tokamaks as well as two spherical tokamaks. Most recently, a report from the TCV tokamak showed a deviation from several of the proposed models (Maurizio et al (TCV team) 2021 Nucl. Fusion 61 024003). In this work, ∼ 100 edge plasma profiles of ELMy H-mode discharges were collected from the COMPASS tokamak database for heat flux analysis. The COMPASS tokamak has a similar machine size and plasma parameters to the TCV tokamak, offering a valuable comparison. The λ q was measured in both downstream and upstream SOL utilizing a divertor probe array validated by an IR camera and Thomson scattering diagnostics. A comparison with the predictions of several scaling models indicated an occurrence of anomalously short (by a factor of 2–5) inter-ELM power decay lengths in both upstream and downstream, as well as a difference in λ q between these two regions. Possible causes related to the accuracy of magnetic reconstruction were eliminated and physics-based sources of apparent compression effects were hypothesized as a motivation for future research.
- Open Access
- 9 August 2022
- Published by IOP Publishing in Nuclear Fusion
- Vol. 62 (9) , 096021
On the applicability of three and four parameter fits for analysis of swept embedded Langmuir probes in magnetised plasma
The problem of power exhaust is one of the grand challenges of nuclear fusion research today. In order to understand the physics phenomena occurring in the scrape-off layer and the divertor regions of tokamaks, it is essential to correctly determine the divertor plasma parameters, which are often measured by swept Langmuir probes (LPs). While the construction and operation of this diagnostic can be straightforward, the data analysis using three- or four-parameter fits presents a challenge and can potentially lead to erroneous values of electron temperature and ion saturation current. In this work, we present modelling and experiments aimed at determination of conditions for proper analysis of swept LPs using these two fitting models. Particle-in-cell modelling was employed to evaluate the sheath-expansion effects for particular probe geometry and plasma conditions, yielding a semi-empirical rule capable of predicting its magnitude. Experiments with unusually wide range of swept voltage in the divertor of the COMPASS tokamak explored the magnitude of voltage range required for successful analysis with either three or four-parameter fitting. With the use of our new semi-empirical rule, it is possible to improve the four-parameter fit reliability in situations where the available voltage range is limited. In addition, we introduce the tangent method—an independent and fast method of electron temperature estimation, which allows to reliably determine the available voltage range and as such assist more complex methods of probe analysis.
- 9 August 2022
- Published by IOP Publishing in Nuclear Fusion
- Vol. 62 (9) , 096021
Open AccessOn the applicability of three and four parameter fits for analysis of swept embedded Langmuir probes in magnetised plasma
The problem of power exhaust is one of the grand challenges of nuclear fusion research today. In order to understand the physics phenomena occurring in the scrape-off layer and the divertor regions of tokamaks, it is essential to correctly determine the divertor plasma parameters, which are often measured by swept Langmuir probes (LPs). While the construction and operation of this diagnostic can be straightforward, the data analysis using three- or four-parameter fits presents a challenge and can potentially lead to erroneous values of electron temperature and ion saturation current. In this work, we present modelling and experiments aimed at determination of conditions for proper analysis of swept LPs using these two fitting models. Particle-in-cell modelling was employed to evaluate the sheath-expansion effects for particular probe geometry and plasma conditions, yielding a semi-empirical rule capable of predicting its magnitude. Experiments with unusually wide range of swept voltage in the divertor of the COMPASS tokamak explored the magnitude of voltage range required for successful analysis with either three or four-parameter fitting. With the use of our new semi-empirical rule, it is possible to improve the four-parameter fit reliability in situations where the available voltage range is limited. In addition, we introduce the tangent method—an independent and fast method of electron temperature estimation, which allows to reliably determine the available voltage range and as such assist more complex methods of probe analysis.
- 1 August 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (8) , 083503
Conceptual design of Thomson scattering diagnostics for the COMPASS-U tokamak
The Thomson scattering (TS) diagnostic, one of the key diagnostics used on the tokamaks around the world, is planned for the COMPASS-U tokamak, which is recently under design and construction in the Institute of Plasma Physics in Prague, Czech Republic. This tokamak is supposed to be a world-unique, high magnetic field device with hot walls, allowing for the study of the plasma exhaust in advanced operational scenarios and testing cutting-edge technologies relevant to future fusion reactors, e.g., use of liquid metals. The core and edge TS systems are planned to be designed and operational, with a limited performance, already in the early stage of the tokamak operation. In this contribution, requirements and the most important constraints defining the TS system design are presented. The impact of both the possible collection lens location and spatial resolution on the plasma pedestal observation is simulated. Design considerations also take into account the high-resolution TS core and edge systems available from the COMPASS tokamak, which will be reused. The collection lenses will be newly built. Extension of the detection system will complete the plasma radius coverage in the future. The divertor TS is considered for later periods.
- 1 August 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (8) , 083503
Conceptual design of Thomson scattering diagnostics for the COMPASS-U tokamak
The Thomson scattering (TS) diagnostic, one of the key diagnostics used on the tokamaks around the world, is planned for the COMPASS-U tokamak, which is recently under design and construction in the Institute of Plasma Physics in Prague, Czech Republic. This tokamak is supposed to be a world-unique, high magnetic field device with hot walls, allowing for the study of the plasma exhaust in advanced operational scenarios and testing cutting-edge technologies relevant to future fusion reactors, e.g., use of liquid metals. The core and edge TS systems are planned to be designed and operational, with a limited performance, already in the early stage of the tokamak operation. In this contribution, requirements and the most important constraints defining the TS system design are presented. The impact of both the possible collection lens location and spatial resolution on the plasma pedestal observation is simulated. Design considerations also take into account the high-resolution TS core and edge systems available from the COMPASS tokamak, which will be reused. The collection lenses will be newly built. Extension of the detection system will complete the plasma radius coverage in the future. The divertor TS is considered for later periods.