Ajay Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ajay Kumar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Rajesh Ghosh
Indian Institute of Technology Mandi
5 shared publications Rajeev Kumar
Indian Institute of Technology Mandi
2 shared publicationsRajesh Ghosh
Biomechanics Laboratory, School of Mechanical and Materials Engineering, Indian Institute of Technology Mandi (IIT Mandi), Mandi, Kamand, Himachal Pradesh, 175075, India
2 shared publications- Himanshu Pathak
Composite Design and Manufacturing Research Group, School of Mechanical and Materials Engineering Indian Institute of Technology Mandi Mandi India
1 shared publication Subrata Mondal
School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin, Ireland
1 shared publication- Subrata Mondal
Queen Mary University of London. SEMS Department, Mile End Campus, London, UK
1 shared publication
Latest Publications
- Open Access
- 25 July 2025
- Published by Elsevier in Next Materials
- Vol. 9
Biomechanics of interfaces for cemented joint replacements: A systematic review
- 25 July 2025
- Published by Elsevier in Next Materials
- Vol. 9
Open AccessBiomechanics of interfaces for cemented joint replacements: A systematic review
- 22 November 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (11-12) , 1091-1102
Cortical bone fracture analysis including the combined influence of osteon orientations, applied load and crack lengths: A numerical investigation
Similar to how fiber orientation affects composite materials, osteon orientation affects the elasticity and fracture behavior of cortical bone. The objective of this work is to predict the combined effect of orientations of the osteon, applied load, and various crack lengths on the fracture characteristics of cortical bone. Orthotropic modeling and analyses of cortical bone were carried out using the linear-elastic fracture mechanics (LEFM) based extended finite element method (XFEM). Five values of applied mode-I and mode-II load, five distinct crack lengths, and seven angular osteon orientations were taken into consideration to predict the change in SIF. In this work, the 2-D plane stress assumption with a straight-edge crack was taken into consideration. It was found that the values of SIF significantly increased when the load (15–35 MPa) and fracture length (1.8–2.2 mm) increased. SIF ( KI) values under mode-I loading were discovered to be substantially lower than SIF ( KI and KII) values under mode-II loading. Results of this study showed that osteon orientations with different crack lengths and applied loads had a significant impact on cortical bone fracture characteristics. Only the crack’s opening was discovered to be caused by mode-I loading; however, both the opening and shearing of the crack were found to be caused by mode-II loading. Despite differences in applied loads, crack lengths, and osteon orientations, the values of the SIF predicted in this work (under mode-I loading) using LEFM-based XFEM exhibited good agreement with the prior published experimental and numerical data.
- 22 November 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (11-12) , 1091-1102
Cortical bone fracture analysis including the combined influence of osteon orientations, applied load and crack lengths: A numerical investigation
Similar to how fiber orientation affects composite materials, osteon orientation affects the elasticity and fracture behavior of cortical bone. The objective of this work is to predict the combined effect of orientations of the osteon, applied load, and various crack lengths on the fracture characteristics of cortical bone. Orthotropic modeling and analyses of cortical bone were carried out using the linear-elastic fracture mechanics (LEFM) based extended finite element method (XFEM). Five values of applied mode-I and mode-II load, five distinct crack lengths, and seven angular osteon orientations were taken into consideration to predict the change in SIF. In this work, the 2-D plane stress assumption with a straight-edge crack was taken into consideration. It was found that the values of SIF significantly increased when the load (15–35 MPa) and fracture length (1.8–2.2 mm) increased. SIF ( KI) values under mode-I loading were discovered to be substantially lower than SIF ( KI and KII) values under mode-II loading. Results of this study showed that osteon orientations with different crack lengths and applied loads had a significant impact on cortical bone fracture characteristics. Only the crack’s opening was discovered to be caused by mode-I loading; however, both the opening and shearing of the crack were found to be caused by mode-II loading. Despite differences in applied loads, crack lengths, and osteon orientations, the values of the SIF predicted in this work (under mode-I loading) using LEFM-based XFEM exhibited good agreement with the prior published experimental and numerical data.
- 16 April 2024
- Published by Elsevier in Journal of Orthopaedics
- Vol. 55, 118-123
Influence of obesity on load-transfer mechanism, contact mechanics, and longevity of cemented acetabular cup
- 16 April 2024
- Published by Elsevier in Journal of Orthopaedics
- Vol. 55, 118-123
Influence of obesity on load-transfer mechanism, contact mechanics, and longevity of cemented acetabular cup
- 22 July 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (9) , 1309-1327
Biomechanical performance of the cemented acetabular cup with combined effects of bone quality, implant material combinations and bodyweight
The objective of this study is to understand the combined effects of bone quality, implant materials and bodyweight on the biomechanical performance of cemented acetabular cup. Additionally, the performance of the cemented acetabular cup was evaluated for obesity cases or obese people. A total of 84 FE models (based on CT data) were developed based on combinations of three different cancellous bone material distributions to represent bone quality, four different implant material combinations and seven different bodyweights. The biomechanical performance of the acetabular cup was evaluated based on bone stress (both cortical and cancellous bone), cement mantle stress, micromotion and contact pressure between the acetabular cup and femoral head. Cortical bone stress, cancellous bone stress, cement stress, the contact pressure between implants and micromotion between implants are affected by different bone quality, implant material combinations and bodyweights. An increase in bodyweight would increase the cortical bone stress, cancellous bone stress, cement stress, contact pressure between implants and micromotion between implants. However, bodyweight affects the cortical and cancellous bone stress more (stiff rise of the bone stresses; nonlinear relation) as compared to other output parameters (mostly linear relation). Comparing cortical and cancellous bone stress, the stress versus bodyweight curve is much stiffer (stiff rise in the curve) for cortical bone than cancellous bone and that even further increases as bone quality decreases. Especially considering obesity cases or obese people (very high bodyweight), the performance of the cemented acetabular component is poor. Graphical [ ]
- 22 July 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (9) , 1309-1327
Biomechanical performance of the cemented acetabular cup with combined effects of bone quality, implant material combinations and bodyweight
The objective of this study is to understand the combined effects of bone quality, implant materials and bodyweight on the biomechanical performance of cemented acetabular cup. Additionally, the performance of the cemented acetabular cup was evaluated for obesity cases or obese people. A total of 84 FE models (based on CT data) were developed based on combinations of three different cancellous bone material distributions to represent bone quality, four different implant material combinations and seven different bodyweights. The biomechanical performance of the acetabular cup was evaluated based on bone stress (both cortical and cancellous bone), cement mantle stress, micromotion and contact pressure between the acetabular cup and femoral head. Cortical bone stress, cancellous bone stress, cement stress, the contact pressure between implants and micromotion between implants are affected by different bone quality, implant material combinations and bodyweights. An increase in bodyweight would increase the cortical bone stress, cancellous bone stress, cement stress, contact pressure between implants and micromotion between implants. However, bodyweight affects the cortical and cancellous bone stress more (stiff rise of the bone stresses; nonlinear relation) as compared to other output parameters (mostly linear relation). Comparing cortical and cancellous bone stress, the stress versus bodyweight curve is much stiffer (stiff rise in the curve) for cortical bone than cancellous bone and that even further increases as bone quality decreases. Especially considering obesity cases or obese people (very high bodyweight), the performance of the cemented acetabular component is poor. Graphical [ ]
- 1 September 2021
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 254
Particularly optimized enriched element-free Galerkin method (POE-EFGM) for orthotropic fracture analysis of cortical bone
- 1 September 2021
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 254
Particularly optimized enriched element-free Galerkin method (POE-EFGM) for orthotropic fracture analysis of cortical bone
- 21 August 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (5) , 1208-1214
Fracture Toughness of Acrylic PMMA Bone Cement: A Mini-Review
Background Acrylic PMMA bone cement is an essential component in cemented implants and formed the cement-bone and cement-implant interfaces. The information on the fracture parameters of PMMA bone cement would be decisive for all doctors, researchers, and orthopaedic surgeons. Purpose This review aims to indicate the parameters responsible for the variation in the fracture toughness of PMMA bone cement. This mini-review also points out some limitations of the earlier published research article, which can be added in the future analysis and can be helpful to get the more realistic data of the fracture parameters of PMMA bone cement. Conclusion Different mixing techniques, storage medium, temperature, loading conditions, frequency and environment, cement viscosity, type of specimen, and the ASTM standards (shape, size, and geometry), constituents, loading rate, and cement porosity were the critical parameters to affect the fracture toughness of PMMA bone cement. This study will also be helpful to increase the structural integrity of PMMA bone cement and the cemented implant.
- 21 August 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (5) , 1208-1214
Fracture Toughness of Acrylic PMMA Bone Cement: A Mini-Review
Background Acrylic PMMA bone cement is an essential component in cemented implants and formed the cement-bone and cement-implant interfaces. The information on the fracture parameters of PMMA bone cement would be decisive for all doctors, researchers, and orthopaedic surgeons. Purpose This review aims to indicate the parameters responsible for the variation in the fracture toughness of PMMA bone cement. This mini-review also points out some limitations of the earlier published research article, which can be added in the future analysis and can be helpful to get the more realistic data of the fracture parameters of PMMA bone cement. Conclusion Different mixing techniques, storage medium, temperature, loading conditions, frequency and environment, cement viscosity, type of specimen, and the ASTM standards (shape, size, and geometry), constituents, loading rate, and cement porosity were the critical parameters to affect the fracture toughness of PMMA bone cement. This study will also be helpful to increase the structural integrity of PMMA bone cement and the cemented implant.
- 22 July 2021
- Published by Springer Nature
- p. 17-26
Effect of Implant Materials on Bone Remodelling Around Cemented Acetabular Cup
- 22 July 2021
- Published by Springer Nature
- p. 17-26
Effect of Implant Materials on Bone Remodelling Around Cemented Acetabular Cup
- 14 November 2020
- Published by Springer Nature
- p. 75-85
Effect of Interfacial Crack on the Prediction of Bone–Cement Interface Failure of Cemented Acetabular Component
- 14 November 2020
- Published by Springer Nature
- p. 75-85
Effect of Interfacial Crack on the Prediction of Bone–Cement Interface Failure of Cemented Acetabular Component