Fohagui Fodoup Cyrille Vincelas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fohagui Fodoup Cyrille Vincelas has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aimee Byrne
Office of the Vice President for Sustainability, Technological University Dublin, Grangegorman Campus, Clock Tower CT101, Grangegorman, D07 XT95 Dublin, Ireland
1 shared publication - Ambe Harrison
Department of Electrical and Electronics Engineering, College of Technology (COT), University of Buea, Buea, Cameroon
1 shared publication Anthony James Robinson
Department of Mechanical and Manufacturing Engineering, Trinity College Dublin
1 shared publication- Ghislain Tchuen
LISIE, IUT-FV Bandjoun, Université de Dschang, B.P. 134, Bandjoun-Cameroun
1 shared publication - Hilaire Bertrand Fotsin
Research Unit of Condensed Matter, Electronics and Signal Processing, Department of Physics, University of Dschang, PO Box 67, Dschang, Cameroon
1 shared publication - Jerome Ndam Mungwe
Department of Electrical and Power Engineering, Higher Technical Teacher Training College HTTTC, The University of Bamenda, Bambili, Cameroon
1 shared publication
Latest Publications
- Open Access
- 26 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 56 (1) , 34
Trio-PV Monitor: A Smart IoT-Based Instrument for Continuous and Reliable Monitoring of Solar PV Installations
This paper introduces a Trio-PV monitor: a smart IoT-based instrument for the continuous and accurate monitoring of solar PV systems. The instrument is a synergistic combination of electronic hardware, desktop applications and a website. It has been conceived to provide monitoring, storage, and sharing as well as to perform statistical operations on solar energy-related data collected at any chosen site. The instrument features high flexibility, with the capacity of monitoring PV plants of up to a 90 kW rating. It is intentionally equipped with large-range weather-proof sensors, permitting monitoring and evaluation across different seasons and geographical areas. The proposed instrument targets six keys operating variables of a PV systems, namely irradiance, panel-temperature, ambient temperature, humidity, PV current and voltage. The automated design of the Trio-PV monitor allows for continuous operation for 12 h within a day. The instrument has been used to monitor simple 30 W solar PV-DC connected systems, with acquired results revealing it practical suitability and soundness. The friendly user interface of the system allows a graphical visualization of monitored parameters in real time through an installed desktop application. Finally, the IoT competence of the proposed instrument extensively allows data acquisition and the monitoring of a PV system from any location in the world. It is envisioned that the developed instrument would be a leverage package for data acquisition and the monitoring of PV system installations in developing countries and especially in Cameroon where access to information on PV systems is still highly costly and unreliable.
- 26 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 56 (1) , 34
Open AccessTrio-PV Monitor: A Smart IoT-Based Instrument for Continuous and Reliable Monitoring of Solar PV Installations
This paper introduces a Trio-PV monitor: a smart IoT-based instrument for the continuous and accurate monitoring of solar PV systems. The instrument is a synergistic combination of electronic hardware, desktop applications and a website. It has been conceived to provide monitoring, storage, and sharing as well as to perform statistical operations on solar energy-related data collected at any chosen site. The instrument features high flexibility, with the capacity of monitoring PV plants of up to a 90 kW rating. It is intentionally equipped with large-range weather-proof sensors, permitting monitoring and evaluation across different seasons and geographical areas. The proposed instrument targets six keys operating variables of a PV systems, namely irradiance, panel-temperature, ambient temperature, humidity, PV current and voltage. The automated design of the Trio-PV monitor allows for continuous operation for 12 h within a day. The instrument has been used to monitor simple 30 W solar PV-DC connected systems, with acquired results revealing it practical suitability and soundness. The friendly user interface of the system allows a graphical visualization of monitored parameters in real time through an installed desktop application. Finally, the IoT competence of the proposed instrument extensively allows data acquisition and the monitoring of a PV system from any location in the world. It is envisioned that the developed instrument would be a leverage package for data acquisition and the monitoring of PV system installations in developing countries and especially in Cameroon where access to information on PV systems is still highly costly and unreliable.
- 6 August 2021
- Published by Springer Nature in Sādhanā
- Vol. 46 (3) , 1-18
Experimental comparison of energy performances of common types of buildings constructed in Cameroon and validation of their electrical model
- 6 August 2021
- Published by Springer Nature in Sādhanā
- Vol. 46 (3) , 1-18
Experimental comparison of energy performances of common types of buildings constructed in Cameroon and validation of their electrical model
- 21 July 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 444-459
The economic and environmental combination between building materials and fuel source to improve building energy performance
This study aims to investigate the economic and environmental combination between building materials and fuel source to improve building energy performance by considering the entransy loss. The annual entransy losses through the residential building walls were determined using the degree-day’s method. Life cycle cost and life cycle assessment were used for the determination of the optimum insulation thickness, entransy saving, environmental impacts and emissions rate of CO2 and SO2. Results Shows that optimum thicknesses vary between 0.04 and 0.08 m, entransy savings shift between 4 and 25 $/m2, environmental impacts between4 and 65 mPts/m2 and emissions of CO2 and SO2 between 1300 and 35000 g/m2, 5 and 60 g/m2, respectively, depending on the wall, fuel and insulation combinations. Light weight concrete block (LWCB) building insulated with polyisocyanurate using natural gas was found to be the best combination.
- 21 July 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 444-459
The economic and environmental combination between building materials and fuel source to improve building energy performance
This study aims to investigate the economic and environmental combination between building materials and fuel source to improve building energy performance by considering the entransy loss. The annual entransy losses through the residential building walls were determined using the degree-day’s method. Life cycle cost and life cycle assessment were used for the determination of the optimum insulation thickness, entransy saving, environmental impacts and emissions rate of CO2 and SO2. Results Shows that optimum thicknesses vary between 0.04 and 0.08 m, entransy savings shift between 4 and 25 $/m2, environmental impacts between4 and 65 mPts/m2 and emissions of CO2 and SO2 between 1300 and 35000 g/m2, 5 and 60 g/m2, respectively, depending on the wall, fuel and insulation combinations. Light weight concrete block (LWCB) building insulated with polyisocyanurate using natural gas was found to be the best combination.