Xiaoyong Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiaoyong Wei has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bai Chen
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
2 shared publications - Feng Ju
Nanjing University of Aeronautics and Astronautics
2 shared publications Hao Guo
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publicationsHongtao Wu
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publicationsBai Chen
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication- Chuang Lu
Hawkes Institute, University College London, London, UK
1 shared publication
Latest Publications
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Design and Compensation Control of Modular Variable Stiffness Continuum Manipulator for Nasal Surgery
Rigid instruments with limited flexibility utilized in the traditional endoscopic sinus surgery maybe damage the tissue when surgeon operates in the narrow space of nose specific area. Flexible continuum manipulator would solve this issue. However, current manipulators may not be able to address the intricate and varied surgical demands effectively, and they may not meet the surgical requirements adequately in terms of the flexibility, precision, and stiffness. This article introduced a novel modular continuum manipulator designed to offer exceptional adaptability, precision, and adjustable stiffness. The various sizes of the manipulators could be optimized according to different surgical scenario while taking its flexibility into account. Moreover, the model-based estimation and feedforward compensation control were applied to enhance its precision, taking into account the coupling effect of two sections and friction loss. Additionally, this study introduced a theoretical analysis on the feasibility of implementing variable stiffness for the manipulator, and the coupling was also lessened via increasing the stiffness of the first section. The experiments demonstrated that the maximum average deviation observed was 3.43 mm, which is equivalent to just 2.5% of the total length of the manipulator. Furthermore, the stiffness could be enhanced by up to 75%. Therefore, the proposed flexible manipulator has a potential for the nasal minimally invasive surgery.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Design and Compensation Control of Modular Variable Stiffness Continuum Manipulator for Nasal Surgery
Rigid instruments with limited flexibility utilized in the traditional endoscopic sinus surgery maybe damage the tissue when surgeon operates in the narrow space of nose specific area. Flexible continuum manipulator would solve this issue. However, current manipulators may not be able to address the intricate and varied surgical demands effectively, and they may not meet the surgical requirements adequately in terms of the flexibility, precision, and stiffness. This article introduced a novel modular continuum manipulator designed to offer exceptional adaptability, precision, and adjustable stiffness. The various sizes of the manipulators could be optimized according to different surgical scenario while taking its flexibility into account. Moreover, the model-based estimation and feedforward compensation control were applied to enhance its precision, taking into account the coupling effect of two sections and friction loss. Additionally, this study introduced a theoretical analysis on the feasibility of implementing variable stiffness for the manipulator, and the coupling was also lessened via increasing the stiffness of the first section. The experiments demonstrated that the maximum average deviation observed was 3.43 mm, which is equivalent to just 2.5% of the total length of the manipulator. Furthermore, the stiffness could be enhanced by up to 75%. Therefore, the proposed flexible manipulator has a potential for the nasal minimally invasive surgery.
- 1 December 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 237 (1) , 35-48
Modeling and control of cable-driven continuum robot used for minimally invasive surgery
Continuum robot has great advantages in minimally invasive surgery (MIS) due to the slenderness and dexterity. But the friction and backlash result in the low trajectory tracking accuracy. This paper aims to study the transmission process of the driving force and the error compensation method. The statics is performed considering the frictional transmission process, and the variation of friction force with driving force is revealed by the model. The hysteresis effect of the tip trajectory is revealed. Then the relationship between the load history and the robot shape is studied, next, the deflection of the robot subject to the different loading forces can be predicted. The correctness of the mechanical model is verified by numerical simulation and experiments. Furthermore, the control methods according to the cable length and the driving force are compared respectively, and a method of error compensation according to the cable length is worked out considering the mechanical model. The rationality of the compensation method is validated by experiment. The results show that the compensation method based on cable length greatly improves the control accuracy, and the maximum deviation is 1.08 mm. The established model and compensation method create conditions for clinical application of the proposed continuum robot.
- 1 December 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 237 (1) , 35-48
Modeling and control of cable-driven continuum robot used for minimally invasive surgery
Continuum robot has great advantages in minimally invasive surgery (MIS) due to the slenderness and dexterity. But the friction and backlash result in the low trajectory tracking accuracy. This paper aims to study the transmission process of the driving force and the error compensation method. The statics is performed considering the frictional transmission process, and the variation of friction force with driving force is revealed by the model. The hysteresis effect of the tip trajectory is revealed. Then the relationship between the load history and the robot shape is studied, next, the deflection of the robot subject to the different loading forces can be predicted. The correctness of the mechanical model is verified by numerical simulation and experiments. Furthermore, the control methods according to the cable length and the driving force are compared respectively, and a method of error compensation according to the cable length is worked out considering the mechanical model. The rationality of the compensation method is validated by experiment. The results show that the compensation method based on cable length greatly improves the control accuracy, and the maximum deviation is 1.08 mm. The established model and compensation method create conditions for clinical application of the proposed continuum robot.
- 31 August 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (6) , e2328
Design and analysis of a continuum robot for transnasal skull base surgery
Background: The traditional surgical instruments for transnasal endoscopic skull base surgery have poor flexibility and continuum robot has attracted extensive attention for its high dexterity and safety.Methods: A new type of micro continuum surgical robot is designed. On the basis of kinematic analysis, a superposition method is proposed to analyse the reachable configuration space of the system, and the workspace is analysed. The results obtained by superposition method can provide reference for the selection of joint parameters. At last, the static model of the system is established considering friction and coupling between two segments.Results: The simulation results show that the workspace can meet the requirements of surgery. And the validity of the static model is verified by numerical simulation and experiment, which lays a foundation for the establishment of the driving force transmission system and precise control of the robot.Conclusions: The research results of this study contribute to the real‐time control and movement of robot. The proposed continuum robot provides convenient conditions for the clinical application.
- 31 August 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (6) , e2328
Design and analysis of a continuum robot for transnasal skull base surgery
Background: The traditional surgical instruments for transnasal endoscopic skull base surgery have poor flexibility and continuum robot has attracted extensive attention for its high dexterity and safety.Methods: A new type of micro continuum surgical robot is designed. On the basis of kinematic analysis, a superposition method is proposed to analyse the reachable configuration space of the system, and the workspace is analysed. The results obtained by superposition method can provide reference for the selection of joint parameters. At last, the static model of the system is established considering friction and coupling between two segments.Results: The simulation results show that the workspace can meet the requirements of surgery. And the validity of the static model is verified by numerical simulation and experiment, which lays a foundation for the establishment of the driving force transmission system and precise control of the robot.Conclusions: The research results of this study contribute to the real‐time control and movement of robot. The proposed continuum robot provides convenient conditions for the clinical application.