Chuang Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chuang Lu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Agostino Stilli
University College London
2 shared publications - Danail Stoyanov
University College London
2 shared publications - Ziting Liang
UCL Hawkes Institute, University College London, London, U.K.
2 shared publications - Bai Chen
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
1 shared publication - Dongming Bai
Key Laboratory of Crop Harvesting Equipment Technology of Zhejiang Province, Jinhua University of Vocational Technology, Jinhua, Zhejiang, China
1 shared publication - Feng Ju
Nanjing University of Aeronautics and Astronautics
1 shared publication
Latest Publications
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Compact High-Performance MR Safe Pneumatic Stepper Motor
Magnetic resonance imaging (MRI)-guided interventions have advanced rapidly due to their superior soft-tissue contrast and real-time imaging capability. To enable actuation for robots and other medical devices used in tumour biopsy and ablation within magnetically sensitive environments, several MRI-compatible pneumatic motors have been developed using 3D printing. Although 3D printing enables the fabrication of pneumatic structures, maintaining airtightness and smooth piston motion within 3D-printed cylinders remains challenging due to tolerance variations and surface roughness. These issues lead to pressure losses, increased air consumption, and reduced torque output during motor operation. To address these challenges, this paper presents a compact, high-performance, easily manufacturable MR Safe pneumatic stepper motor that circumvents 3D-printing tolerance limitations by employing prefabricated cylinders. The motor combines a replaceable design with great airtightness and high torque performance. The proposed design achieves negligible air leakage of 0.047 mL/min measured via a designed water displacement method and a maximum output torque of 1.04 Nm at 3.7 revolutions per minute (rpm) under 6 bar, without an additional gearbox. The motor has a compact design, 48 × 48 × 36 mm, which enables the motor to be integrated into the medical devices within the narrow MRI scanning bore.
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Compact High-Performance MR Safe Pneumatic Stepper Motor
Magnetic resonance imaging (MRI)-guided interventions have advanced rapidly due to their superior soft-tissue contrast and real-time imaging capability. To enable actuation for robots and other medical devices used in tumour biopsy and ablation within magnetically sensitive environments, several MRI-compatible pneumatic motors have been developed using 3D printing. Although 3D printing enables the fabrication of pneumatic structures, maintaining airtightness and smooth piston motion within 3D-printed cylinders remains challenging due to tolerance variations and surface roughness. These issues lead to pressure losses, increased air consumption, and reduced torque output during motor operation. To address these challenges, this paper presents a compact, high-performance, easily manufacturable MR Safe pneumatic stepper motor that circumvents 3D-printing tolerance limitations by employing prefabricated cylinders. The motor combines a replaceable design with great airtightness and high torque performance. The proposed design achieves negligible air leakage of 0.047 mL/min measured via a designed water displacement method and a maximum output torque of 1.04 Nm at 3.7 revolutions per minute (rpm) under 6 bar, without an additional gearbox. The motor has a compact design, 48 × 48 × 36 mm, which enables the motor to be integrated into the medical devices within the narrow MRI scanning bore.
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 9575-9584
GelPoLight: A Novel Visual-Tactile Sensor Based on Photometric Stereo With Point Lighting
Visual tactile sensors based on photometric stereo (VTS-PS) have attracted much attention due to their sensitivity to subtle contact forces and their capability of providing real-time, high-resolution depth maps of contact geometry at a low cost. Conventional VTS-PS, such as Gelsight, typically assume directional and uniform illumination to simplify the algorithm of photometric stereo. However, this assumption poses stringent requirement on the hardware side and limits the sensors in shape, size and flexibility for various applications. Additionally, the configuration of directional lighting exacerbates the issue of cast shadowing. In this paper, We analyse the benefits of point lighting over conventional directional lighting for VTS-PS, and propose GelPoLight: a novel VTS-PS with point lighting, which can help handle or alleviate the aforementioned problems. GelPoLight does not assume ideal diffuse reflectance for the reflective membrane and considers the varying influencing factors of light intensity, light directions, and reflectance factors in the estimation of surface normal vectors. Accordingly, we developed a new calibration method for this approach. We also corrected image distortions caused by light refraction, which is a prevalent issue in visual tactile sensors (VTS). The final results demonstrate that GelPoLight can effectively generate the contact depth map, with errors of approximately 5% in planar direction and 8% in depth direction.
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 9575-9584
GelPoLight: A Novel Visual-Tactile Sensor Based on Photometric Stereo With Point Lighting
Visual tactile sensors based on photometric stereo (VTS-PS) have attracted much attention due to their sensitivity to subtle contact forces and their capability of providing real-time, high-resolution depth maps of contact geometry at a low cost. Conventional VTS-PS, such as Gelsight, typically assume directional and uniform illumination to simplify the algorithm of photometric stereo. However, this assumption poses stringent requirement on the hardware side and limits the sensors in shape, size and flexibility for various applications. Additionally, the configuration of directional lighting exacerbates the issue of cast shadowing. In this paper, We analyse the benefits of point lighting over conventional directional lighting for VTS-PS, and propose GelPoLight: a novel VTS-PS with point lighting, which can help handle or alleviate the aforementioned problems. GelPoLight does not assume ideal diffuse reflectance for the reflective membrane and considers the varying influencing factors of light intensity, light directions, and reflectance factors in the estimation of surface normal vectors. Accordingly, we developed a new calibration method for this approach. We also corrected image distortions caused by light refraction, which is a prevalent issue in visual tactile sensors (VTS). The final results demonstrate that GelPoLight can effectively generate the contact depth map, with errors of approximately 5% in planar direction and 8% in depth direction.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Design and Compensation Control of Modular Variable Stiffness Continuum Manipulator for Nasal Surgery
Rigid instruments with limited flexibility utilized in the traditional endoscopic sinus surgery maybe damage the tissue when surgeon operates in the narrow space of nose specific area. Flexible continuum manipulator would solve this issue. However, current manipulators may not be able to address the intricate and varied surgical demands effectively, and they may not meet the surgical requirements adequately in terms of the flexibility, precision, and stiffness. This article introduced a novel modular continuum manipulator designed to offer exceptional adaptability, precision, and adjustable stiffness. The various sizes of the manipulators could be optimized according to different surgical scenario while taking its flexibility into account. Moreover, the model-based estimation and feedforward compensation control were applied to enhance its precision, taking into account the coupling effect of two sections and friction loss. Additionally, this study introduced a theoretical analysis on the feasibility of implementing variable stiffness for the manipulator, and the coupling was also lessened via increasing the stiffness of the first section. The experiments demonstrated that the maximum average deviation observed was 3.43 mm, which is equivalent to just 2.5% of the total length of the manipulator. Furthermore, the stiffness could be enhanced by up to 75%. Therefore, the proposed flexible manipulator has a potential for the nasal minimally invasive surgery.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Design and Compensation Control of Modular Variable Stiffness Continuum Manipulator for Nasal Surgery
Rigid instruments with limited flexibility utilized in the traditional endoscopic sinus surgery maybe damage the tissue when surgeon operates in the narrow space of nose specific area. Flexible continuum manipulator would solve this issue. However, current manipulators may not be able to address the intricate and varied surgical demands effectively, and they may not meet the surgical requirements adequately in terms of the flexibility, precision, and stiffness. This article introduced a novel modular continuum manipulator designed to offer exceptional adaptability, precision, and adjustable stiffness. The various sizes of the manipulators could be optimized according to different surgical scenario while taking its flexibility into account. Moreover, the model-based estimation and feedforward compensation control were applied to enhance its precision, taking into account the coupling effect of two sections and friction loss. Additionally, this study introduced a theoretical analysis on the feasibility of implementing variable stiffness for the manipulator, and the coupling was also lessened via increasing the stiffness of the first section. The experiments demonstrated that the maximum average deviation observed was 3.43 mm, which is equivalent to just 2.5% of the total length of the manipulator. Furthermore, the stiffness could be enhanced by up to 75%. Therefore, the proposed flexible manipulator has a potential for the nasal minimally invasive surgery.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 0149645X,p. 1-4
A 20 GHz 1.9 dB NF LNA with distributed notch filtering for VSAT applications
This paper presents a 20 GHz low noise amplifier (LNA) with notch filtering from 27.5 GHz to 31 GHz in a 0.25 μm SiGe:C BiCMOS technology. Notch filters are proposed to be implemented at different stages to have minor impact on the noise figure (NF), while achieving high attenuation around 30 GHz. In comparison with a reference LNA without filtering, it achieves overall filtering of more than -30 dB from 27.5 GHz to 31 GHz, with a NF of 1.9 dB degraded by only 0.1 dB to 0.4 dB. More than 17 dB improvement is achieved on the gain compression and triple beat IIP3 in presence of high power blocker. Besides, both LNA's achieve best NF to-date with high overall performance at K-band in silicon technologies.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 0149645X,p. 1-4
A 20 GHz 1.9 dB NF LNA with distributed notch filtering for VSAT applications
This paper presents a 20 GHz low noise amplifier (LNA) with notch filtering from 27.5 GHz to 31 GHz in a 0.25 μm SiGe:C BiCMOS technology. Notch filters are proposed to be implemented at different stages to have minor impact on the noise figure (NF), while achieving high attenuation around 30 GHz. In comparison with a reference LNA without filtering, it achieves overall filtering of more than -30 dB from 27.5 GHz to 31 GHz, with a NF of 1.9 dB degraded by only 0.1 dB to 0.4 dB. More than 17 dB improvement is achieved on the gain compression and triple beat IIP3 in presence of high power blocker. Besides, both LNA's achieve best NF to-date with high overall performance at K-band in silicon technologies.