Yaxiang Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yaxiang Zeng has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Remco John Wiegerink
MESA+ Institute, University of Twente, Enschede, The Netherlands
4 shared publications - Jarno Groenesteijn
MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
2 shared publications Joost C. Lotters
MESA+ Institute for Nanotechnology, University of Twente, Netherlands
2 shared publications- Joost C. Lotters
MESA+ Institute for Nanotechnology, University of Twente, 7522 NB Enschede, The Netherlands
2 shared publications - Remco G. P. Sanders
Integrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands
2 shared publications - Dennis Alveringh
MESA+ Institute, University of Twente, Enschede, AE, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 11 August 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (8)
Inline Microfluidic Thermal Conductivity Sensor Using a Suspended Highly-Doped Silicon Heater
This paper reports on a microfluidic sensor for inline measurement of the thermal conductivity of liquids at flow rates up to 1 g/h. The sensor contains a highly-doped silicon heater suspended in a 1 mm long microchannel that is 60 μm wide and 60 μm deep. The heater element is positioned 30 μm deep inside the microchannel to increase the contact area with the fluid and to reduce heat losses to the environment. Moreover, cavities at either side are designed to thermally isolate the microchannel, reducing the power consumption of the heater to 10 mW. The sensor is characterised through a range of different binary liquid mixtures, yielding a thermal conductivity range from 0.169 W/(m·K) (ethanol) up to 0.617 W/(m·K) (water). The analytical model coincides closely with the measurements. For practical applications, calibration curves are provided, yielding accuracies within 4% and 5% at 0 g/h and 1 g/h, respectively. Furthermore, the fabrication technology allows for further on-chip integration with other inline microfluidic sensors, which is relevant for compensating the response of microfabricated thermal flow sensors and fluid composition analysis.
- 11 August 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (8)
Open AccessInline Microfluidic Thermal Conductivity Sensor Using a Suspended Highly-Doped Silicon Heater
This paper reports on a microfluidic sensor for inline measurement of the thermal conductivity of liquids at flow rates up to 1 g/h. The sensor contains a highly-doped silicon heater suspended in a 1 mm long microchannel that is 60 μm wide and 60 μm deep. The heater element is positioned 30 μm deep inside the microchannel to increase the contact area with the fluid and to reduce heat losses to the environment. Moreover, cavities at either side are designed to thermally isolate the microchannel, reducing the power consumption of the heater to 10 mW. The sensor is characterised through a range of different binary liquid mixtures, yielding a thermal conductivity range from 0.169 W/(m·K) (ethanol) up to 0.617 W/(m·K) (water). The analytical model coincides closely with the measurements. For practical applications, calibration curves are provided, yielding accuracies within 4% and 5% at 0 g/h and 1 g/h, respectively. Furthermore, the fabrication technology allows for further on-chip integration with other inline microfluidic sensors, which is relevant for compensating the response of microfabricated thermal flow sensors and fluid composition analysis.
- Open Access
Air Damping Analysis of a Micro-Coriolis Mass Flow Sensor
A micro-Coriolis mass flow sensor is a resonating device that measures small mass flows of fluid. A large vibration amplitude is desired as the Coriolis forces due to mass flow and, accordingly, the signal-to-noise ratio, are directly proportional to the vibration amplitude. Therefore, it is important to maximize the quality factor Q so that a large vibration amplitude can be achieved without requiring high actuation voltages and high power consumption. This paper presents an investigation of the Q factor of different devices in different resonant modes. Q factors were measured both at atmospheric pressure and in vacuum. The measurement results are compared with theoretical predictions. In the atmospheric environment, the Q factor increases when the resonance frequency increases. When reducing the pressure from 1 bar to bar, the Q factor almost doubles. At even lower pressures, the Q factor is inversely proportional to the pressure until intrinsic effects start to dominate, resulting in a maximum Q factor of approximately 7200.Open AccessAir Damping Analysis of a Micro-Coriolis Mass Flow Sensor
A micro-Coriolis mass flow sensor is a resonating device that measures small mass flows of fluid. A large vibration amplitude is desired as the Coriolis forces due to mass flow and, accordingly, the signal-to-noise ratio, are directly proportional to the vibration amplitude. Therefore, it is important to maximize the quality factor Q so that a large vibration amplitude can be achieved without requiring high actuation voltages and high power consumption. This paper presents an investigation of the Q factor of different devices in different resonant modes. Q factors were measured both at atmospheric pressure and in vacuum. The measurement results are compared with theoretical predictions. In the atmospheric environment, the Q factor increases when the resonance frequency increases. When reducing the pressure from 1 bar to bar, the Q factor almost doubles. At even lower pressures, the Q factor is inversely proportional to the pressure until intrinsic effects start to dominate, resulting in a maximum Q factor of approximately 7200. - 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 59-62
Micro Coriolis Mass Flow Sensor with Piezoelectric Transducers for Both Actuation and Readout
We have realized a micro Coriolis mass flow sensor with piezoelectric transducers for both actuation and readout, resulting in lower power consumption and improved robustness to shock in comparison to the current actuation and readout methods. The PZT thin film in the parallel plate piezoelectric transducers was deposited by pulsed laser deposition (PLD). This paper presents the design, fabrication process and initial characterization results with mass flow of water and nitrogen.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 59-62
Micro Coriolis Mass Flow Sensor with Piezoelectric Transducers for Both Actuation and Readout
We have realized a micro Coriolis mass flow sensor with piezoelectric transducers for both actuation and readout, resulting in lower power consumption and improved robustness to shock in comparison to the current actuation and readout methods. The PZT thin film in the parallel plate piezoelectric transducers was deposited by pulsed laser deposition (PLD). This paper presents the design, fabrication process and initial characterization results with mass flow of water and nitrogen.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (6) , 885-896
Design, Fabrication, and Characterization of a Micro Coriolis Mass Flow Sensor Driven by PZT Thin Film Actuators
A micro Coriolis flow sensor accurately measures small mass flows without being affected by properties of the fluid. This paper presents a micro Coriolis mass flow sensor driven by PZT thin film piezoelectric actuators, which allows a combination of large actuation force, low power dissipation and virtually no self-heating. The sensor was fabricated using surface channel technology, resulting in a tube diameter of 40 $\mu \text{m}$ and a thin silicon-rich silicon nitride tube wall of 1.2 $\mu \text{m}$ thick, with a few additional steps to form the integrated piezoelectric actuators. The integrated actuators can actuate the sensor into both swing mode and twist mode. Both actuation modes were evaluated for different fluids and the results are presented in this paper. In the case of swing mode actuation, an optical readout was used to detect the resulting Coriolis movement, resulting in a relatively low sensitivity. In the case of twist mode actuation, a capacitive readout was used and, in comparison to previously published devices, a high mass flow sensitivity was achieved thanks to an optimized readout design. The measurement results show the read-out noise has a standard deviation of 0.15% of the full scale of 1.8 gh −1 when actuated in the twist mode. [2020-0392]
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (6) , 885-896
Design, Fabrication, and Characterization of a Micro Coriolis Mass Flow Sensor Driven by PZT Thin Film Actuators
A micro Coriolis flow sensor accurately measures small mass flows without being affected by properties of the fluid. This paper presents a micro Coriolis mass flow sensor driven by PZT thin film piezoelectric actuators, which allows a combination of large actuation force, low power dissipation and virtually no self-heating. The sensor was fabricated using surface channel technology, resulting in a tube diameter of 40 $\mu \text{m}$ and a thin silicon-rich silicon nitride tube wall of 1.2 $\mu \text{m}$ thick, with a few additional steps to form the integrated piezoelectric actuators. The integrated actuators can actuate the sensor into both swing mode and twist mode. Both actuation modes were evaluated for different fluids and the results are presented in this paper. In the case of swing mode actuation, an optical readout was used to detect the resulting Coriolis movement, resulting in a relatively low sensitivity. In the case of twist mode actuation, a capacitive readout was used and, in comparison to previously published devices, a high mass flow sensitivity was achieved thanks to an optimized readout design. The measurement results show the read-out noise has a standard deviation of 0.15% of the full scale of 1.8 gh −1 when actuated in the twist mode. [2020-0392]
- Open Access
- 20 March 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (3) , 325
A Flow-Through Microfluidic Relative Permittivity Sensor
In this paper, we present the design, simulation, fabrication and characterization of a microfluidic relative permittivity sensor in which the fluid flows through an interdigitated electrode structure. Sensor fabrication is based on an silicon on insulator (SOI) wafer where the fluidic inlet and outlet are etched through the handle layer and the interdigitated electrodes are made in the device layer. An impedance analyzer was used to measure the impedance between the interdigitated electrodes for various non-conducting fluids with a relative permittivity ranging from 1 to 41. The sensor shows good linearity over this range of relative permittivity and can be integrated with other microfluidic sensors in a multiparameter chip.
- 20 March 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (3) , 325
Open AccessA Flow-Through Microfluidic Relative Permittivity Sensor
In this paper, we present the design, simulation, fabrication and characterization of a microfluidic relative permittivity sensor in which the fluid flows through an interdigitated electrode structure. Sensor fabrication is based on an silicon on insulator (SOI) wafer where the fluidic inlet and outlet are etched through the handle layer and the interdigitated electrodes are made in the device layer. An impedance analyzer was used to measure the impedance between the interdigitated electrodes for various non-conducting fluids with a relative permittivity ranging from 1 to 41. The sensor shows good linearity over this range of relative permittivity and can be integrated with other microfluidic sensors in a multiparameter chip.