Stephan Schreiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stephan Schreiner has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Stephan Funk
Friedrich-Alexander Universität Erlangen-Nürnberg
8 shared publications - Constantin Rauch
Friedrich Alexander Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys Ecap, Nikolaus Fiebiger Str 2, D-91058 Erlangen, Germany
7 shared publications - Bernhard Akstaller
Friedrich Alexander Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys Ecap, Nikolaus Fiebiger Str 2, D-91058 Erlangen, Germany
6 shared publications - Gisela Anton
Erlangen Centre for Astroparticle Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, D-91058 Erlangen, Germany
6 shared publications - Thilo Michel
Friedrich Alexander Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys Ecap, Nikolaus Fiebiger Str 2, D-91058 Erlangen, Germany
6 shared publications - Veronika Ludwig
Friedrich Alexander Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys Ecap, Nikolaus Fiebiger Str 2, D-91058 Erlangen, Germany
6 shared publications
Latest Publications
- Open Access
- 12 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065413
Enhanced grating characterization method for absorbing x-ray gratings by bidirectional angular x-ray transmission
High-quality x-ray absorption gratings are essential for grating-based x-ray phase-contrast imaging. Bidirectional angular x-ray transmission (AXT) measurements, as proposed in this work, allow for large-area and nondestructive characterization of these gratings. A custom setup consisting of two rotational axes is used to measure the transmission of x-ray absorption gratings under rotation. From the transmission values and rotation angles, pixelwise transmission profiles are reconstructed. From these transmission profiles, parameter maps that carry information about the microstructure of the grating are retrieved via a fitting procedure. Compared to unidirectional AXT measurements, more detailed and complementary parameter maps are obtained, revealing more defects and parameter variations. Apart from duty cycle, absorber height, and absorber inclination, the bidirectional measurements also provide access to grating lamella rotation on the substrate and to auxiliary structures introduced to increase grating stability. Furthermore, a novel correction technique is introduced to address projective distortions in individual radiographs caused by the rotations. This method relies on calibration phantom measurements to track the movement of registration points under the same rotations as the gratings. Based on the movement of the registration points, the distortions are reconstructed, and appropriate deformation vector fields are calculated and applied to measurement data, achieving a correction with a precision of about two pixels.
- 12 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065413
Open AccessEnhanced grating characterization method for absorbing x-ray gratings by bidirectional angular x-ray transmission
High-quality x-ray absorption gratings are essential for grating-based x-ray phase-contrast imaging. Bidirectional angular x-ray transmission (AXT) measurements, as proposed in this work, allow for large-area and nondestructive characterization of these gratings. A custom setup consisting of two rotational axes is used to measure the transmission of x-ray absorption gratings under rotation. From the transmission values and rotation angles, pixelwise transmission profiles are reconstructed. From these transmission profiles, parameter maps that carry information about the microstructure of the grating are retrieved via a fitting procedure. Compared to unidirectional AXT measurements, more detailed and complementary parameter maps are obtained, revealing more defects and parameter variations. Apart from duty cycle, absorber height, and absorber inclination, the bidirectional measurements also provide access to grating lamella rotation on the substrate and to auxiliary structures introduced to increase grating stability. Furthermore, a novel correction technique is introduced to address projective distortions in individual radiographs caused by the rotations. This method relies on calibration phantom measurements to track the movement of registration points under the same rotations as the gratings. Based on the movement of the registration points, the distortions are reconstructed, and appropriate deformation vector fields are calculated and applied to measurement data, achieving a correction with a precision of about two pixels.
- Open Access
- 20 June 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (4)
Demonstrating grating-based phase-contrast imaging of laser-driven shock waves
Single-shot X-ray phase-contrast imaging is used to take high-resolution images of laser-driven strong shock waves. Employing a two-grating Talbot interferometer, we successfully acquire standard absorption, differential phase-contrast, and dark-field images of the shocked target. Good agreement is demonstrated between experimental data and the results of two-dimensional radiation hydrodynamics simulations of the laser–plasma interaction. The main sources of image noise are identified through a thorough assessment of the interferometer’s performance. The acquired images demonstrate that grating-based phase-contrast imaging is a powerful diagnostic tool for high-energy-density science. In addition, we make a novel attempt at using the dark-field image as a signal modality of Talbot interferometry to identify the microstructure of a foam target.
- 20 June 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (4)
Open AccessDemonstrating grating-based phase-contrast imaging of laser-driven shock waves
Single-shot X-ray phase-contrast imaging is used to take high-resolution images of laser-driven strong shock waves. Employing a two-grating Talbot interferometer, we successfully acquire standard absorption, differential phase-contrast, and dark-field images of the shocked target. Good agreement is demonstrated between experimental data and the results of two-dimensional radiation hydrodynamics simulations of the laser–plasma interaction. The main sources of image noise are identified through a thorough assessment of the interferometer’s performance. The acquired images demonstrate that grating-based phase-contrast imaging is a powerful diagnostic tool for high-energy-density science. In addition, we make a novel attempt at using the dark-field image as a signal modality of Talbot interferometry to identify the microstructure of a foam target.
- Open Access
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , E06004
ERRATUM: Design of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , E06004
Open AccessERRATUM: Design of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
- Open Access
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05004
Design of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
Laser-driven shock waves in matter propagate with multiple kilometers per second and therefore require sources like a laser-driven backlighter, which emit the X-rays within picoseconds, to be able to capture sharp images. The small spatial extent of shocks in low-density materials pose challenges on the imaging setup. In this work, we present a design process for a single-shot X-ray phase-contrast imaging system geared towards these objects, consisting of a two-grating Talbot interferometer and a digital X-ray detector. This imaging system is optimized with respect to the detectable refraction angle of the X-rays induced by an object, which implies a high phase sensitivity. Therefore, an optimization parameter is defined that considers experimental constraints such as the limited number of photons, the required magnification, the size and spectrum of the X-ray source, and the visibility of the moiré fringes. In this way, a large parameter space is sampled and a suitable imaging system is chosen. During a campaign at the PHELIX high-power laser facility a static test sample was imaged which is used to benchmark the optimization process and the imaging system under real conditions. The results show good agreement with the predicted performance, which demonstrates the reliability of the presented design process. Likewise, the process can be adapted to other types of laser experiments or X-ray sources and is not limited to the application presented here.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05004
Open AccessDesign of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
Laser-driven shock waves in matter propagate with multiple kilometers per second and therefore require sources like a laser-driven backlighter, which emit the X-rays within picoseconds, to be able to capture sharp images. The small spatial extent of shocks in low-density materials pose challenges on the imaging setup. In this work, we present a design process for a single-shot X-ray phase-contrast imaging system geared towards these objects, consisting of a two-grating Talbot interferometer and a digital X-ray detector. This imaging system is optimized with respect to the detectable refraction angle of the X-rays induced by an object, which implies a high phase sensitivity. Therefore, an optimization parameter is defined that considers experimental constraints such as the limited number of photons, the required magnification, the size and spectrum of the X-ray source, and the visibility of the moiré fringes. In this way, a large parameter space is sampled and a suitable imaging system is chosen. During a campaign at the PHELIX high-power laser facility a static test sample was imaged which is used to benchmark the optimization process and the imaging system under real conditions. The results show good agreement with the predicted performance, which demonstrates the reliability of the presented design process. Likewise, the process can be adapted to other types of laser experiments or X-ray sources and is not limited to the application presented here.
- Open Access
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Publisher’s Note: “Electromagnetic pulse protective shielding for digital x-ray detectors” [Rev. Sci. Instrum. 94, 075106 (2023)]
This article was originally published online on 21 July 2023 with typesetting errors. These errors have been corrected. AIP Publishing apologizes for the errors
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Open AccessPublisher’s Note: “Electromagnetic pulse protective shielding for digital x-ray detectors” [Rev. Sci. Instrum. 94, 075106 (2023)]
This article was originally published online on 21 July 2023 with typesetting errors. These errors have been corrected. AIP Publishing apologizes for the errors
- Open Access
- 1 July 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Electromagnetic pulse protective shielding for digital x-ray detectors
Laser-driven x-ray backlighting can be used to image fast dynamic processes like the propagation of laser-driven shock waves in matter. We demonstrate and evaluate the feasibility of operating the JUNGFRAU detector designed by PSI, a direct detecting x-ray detector, in environments with extreme electromagnetic pulses. The electromagnetic pulse-protective housing is specifically designed for this detector and optimized for pump-probe experiments at the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) facility at the GSI Helmholtzzentrum für Schwerionenforschung GmbH. The beryllium x-ray entrance window of the protective housing has a high x-ray transmission of 94% at 8 keV. Measurements have shown that the housing simultaneously provides a relative damping of the electromagnetic field on average higher than 1000 in the frequency range of 100 MHz to 5 GHz. The results demonstrate the feasibility of operating digital detectors in experiments where strong electromagnetic pulses are present.
- 1 July 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Open AccessElectromagnetic pulse protective shielding for digital x-ray detectors
Laser-driven x-ray backlighting can be used to image fast dynamic processes like the propagation of laser-driven shock waves in matter. We demonstrate and evaluate the feasibility of operating the JUNGFRAU detector designed by PSI, a direct detecting x-ray detector, in environments with extreme electromagnetic pulses. The electromagnetic pulse-protective housing is specifically designed for this detector and optimized for pump-probe experiments at the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) facility at the GSI Helmholtzzentrum für Schwerionenforschung GmbH. The beryllium x-ray entrance window of the protective housing has a high x-ray transmission of 94% at 8 keV. Measurements have shown that the housing simultaneously provides a relative damping of the electromagnetic field on average higher than 1000 in the frequency range of 100 MHz to 5 GHz. The results demonstrate the feasibility of operating digital detectors in experiments where strong electromagnetic pulses are present.
- Open Access
- 24 August 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (9) , 226
X-ray Dark-Field Imaging for Improved Contrast in Historical Handwritten Literature
If ancient documents are too fragile to be opened, X-ray imaging can be used to recover the content non-destructively. As an extension to conventional attenuation imaging, dark-field imaging provides access to microscopic structural object information, which can be especially advantageous for materials with weak attenuation contrast, such as certain metal-free inks in paper. With cotton paper and different self-made inks based on authentic recipes, we produced test samples for attenuation and dark-field imaging at a metal-jet X-ray source. The resulting images show letters written in metal-free ink that were recovered via grating-based dark-field imaging. Without the need for synchrotron-like beam quality, these results set the ground for a mobile dark-field imaging setup that could be brought to a library for document scanning, avoiding long transport routes for valuable historic documents.
- 24 August 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (9) , 226
Open AccessX-ray Dark-Field Imaging for Improved Contrast in Historical Handwritten Literature
If ancient documents are too fragile to be opened, X-ray imaging can be used to recover the content non-destructively. As an extension to conventional attenuation imaging, dark-field imaging provides access to microscopic structural object information, which can be especially advantageous for materials with weak attenuation contrast, such as certain metal-free inks in paper. With cotton paper and different self-made inks based on authentic recipes, we produced test samples for attenuation and dark-field imaging at a metal-jet X-ray source. The resulting images show letters written in metal-free ink that were recovered via grating-based dark-field imaging. Without the need for synchrotron-like beam quality, these results set the ground for a mobile dark-field imaging setup that could be brought to a library for document scanning, avoiding long transport routes for valuable historic documents.
- Open Access
- 5 September 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Noise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.
- 5 September 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Open AccessNoise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.