Phaly Ham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Phaly Ham has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Saret Bun
Faculty of Hydrology and Water Resources Engineering, Institute of Technology of Cambodia, Phnom Penh 12156, Cambodia
4 shared publications - Pisut Painmanakul
Chulalongkorn University
3 shared publications - Borith Pang1 shared publication
- Chantha Oeurng
Faculty of Hydrology and Water Resources Engineering, Institute of Technology of Cambodia, Russian Federation Blvd., Phnom Penh 12156, Cambodia
1 shared publication - Kimeng Sou1 shared publication
- Kritchart Wongwailikhit
Center of Excellence in Particle and Materials Processing Technology, Department of Chemical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
1 shared publication
Latest Publications
- Open Access
- 13 October 2026
- Published by AccScience Publishing in Explora: Environment and Resource
- p. 026290028
On-site anaerobic treatment of mediumstrength wastewater under different hydraulic retention times
Decentralized anaerobic wastewater treatment technologies have attracted growing attention because of their low energy requirements, simple operation, and suitability for developing countries. This study evaluated and compared the treatment performance of an anaerobic baffled reactor (ABR) and anaerobic filter (AF) treating medium-strength wastewater under hydraulic retention times (HRTs) of 12 h and 24 h. Laboratory-scale reactors were operated under continuous-flow conditions using domestic wastewater. Both systems were operated under natural sludge growth conditions and monitored through start-up and steady-state stages. Reactor performance was assessed based on pH, total suspended solids (TSS), volatile suspended solids, biochemical oxygen demand, chemical oxygen demand (COD), alkalinity, and volatile fatty acids. The results showed that increasing HRT improved treatment performance in both reactors. During steady-state operation, ABR achieved COD removal efficiencies of 39.34% and 50.14% at HRTs of 12 h and 24 h, respectively, while AF achieved higher COD removals of 55.74% and 73.56% under the same conditions. Similarly, TSS removal efficiencies increased from 76.45% to 78.57% in ABR and from 84.06% to 88.45% in AF when HRT was increased from 12 h to 24 h. Compartmental analysis showed progressive pollutant removal in both reactors, while AF consistently performed better due to enhanced biomass retention and attached microbial growth. Additional adsorption experiments demonstrated that sponge media contributed substantially to particle retention and turbidity removal, achieving approximately 90% turbidity reduction after 24 h of contact time. Biodegradation analysis further indicated that organic removal followed first-order kinetics with a degradation constant of 0.02 h−1. In conclusion, AF operated at 24 h HRT demonstrated the highest treatment efficiency and was identified as the optimum configuration for medium-strength wastewater treatment. The findings highlight the potential of attached-growth anaerobic systems as effective and sustainable alternatives for decentralized wastewater management.
- 13 October 2026
- Published by AccScience Publishing in Explora: Environment and Resource
- p. 026290028
Open AccessOn-site anaerobic treatment of mediumstrength wastewater under different hydraulic retention times
Decentralized anaerobic wastewater treatment technologies have attracted growing attention because of their low energy requirements, simple operation, and suitability for developing countries. This study evaluated and compared the treatment performance of an anaerobic baffled reactor (ABR) and anaerobic filter (AF) treating medium-strength wastewater under hydraulic retention times (HRTs) of 12 h and 24 h. Laboratory-scale reactors were operated under continuous-flow conditions using domestic wastewater. Both systems were operated under natural sludge growth conditions and monitored through start-up and steady-state stages. Reactor performance was assessed based on pH, total suspended solids (TSS), volatile suspended solids, biochemical oxygen demand, chemical oxygen demand (COD), alkalinity, and volatile fatty acids. The results showed that increasing HRT improved treatment performance in both reactors. During steady-state operation, ABR achieved COD removal efficiencies of 39.34% and 50.14% at HRTs of 12 h and 24 h, respectively, while AF achieved higher COD removals of 55.74% and 73.56% under the same conditions. Similarly, TSS removal efficiencies increased from 76.45% to 78.57% in ABR and from 84.06% to 88.45% in AF when HRT was increased from 12 h to 24 h. Compartmental analysis showed progressive pollutant removal in both reactors, while AF consistently performed better due to enhanced biomass retention and attached microbial growth. Additional adsorption experiments demonstrated that sponge media contributed substantially to particle retention and turbidity removal, achieving approximately 90% turbidity reduction after 24 h of contact time. Biodegradation analysis further indicated that organic removal followed first-order kinetics with a degradation constant of 0.02 h−1. In conclusion, AF operated at 24 h HRT demonstrated the highest treatment efficiency and was identified as the optimum configuration for medium-strength wastewater treatment. The findings highlight the potential of attached-growth anaerobic systems as effective and sustainable alternatives for decentralized wastewater management.
- Open Access
- 4 January 2022
- Published by MDPI AG in Chemengineering
- Vol. 6 (1) , 3
Development of Integrated Electrocoagulation-Sedimentation (IECS) in Continuous Mode for Turbidity and Color Removal
The present work focused on the development and evaluation of a compact electrocoagulation (EC) reactor, combined between EC and clarifier processes in continuous modes for decolorization and turbidity removal, named the integrated electrocoagulation-sedimentation reactor (IECS). The experiments were firstly conducted in the four-liter batch column in order to optimize the EC configuration and operation condition. The removal kinetics were also investigated and predicted for kinetic correlations. After various optimization steps, the IECS reactor was conducted, consisting of EC and clarifier compartments. Liquid flow pattern in EC compartment was examined through resident time distribution technique for defining the number of EC units and divided baffles. In summary, four units of EC were placed in the EC compartment of the IECS reactor with 90% in the width of three baffles. Each EC unit had two pairs of aluminum electrode plats in monopolar arrangement with a 1.5 cm gap and required a current density of 13.5 mA/cm2. For the clarifier compartment, it was mainly designed based on the batch settling test for separating the precipitated particles. The treatment performance of the IECS reactor was tested at different liquid flows in order to reduce the pollutant to a certain level. For the individual condition, liquid flow rates of 3 and 1 L/min were defined for turbidity and color, respectively. If both pollutants are presented simultaneously, a liquid flow rate of 1–2 L/min can be used for decreasing turbidity from 250 to <20 NTU and color from 6000 to <300 ADMI.
- 4 January 2022
- Published by MDPI AG in Chemengineering
- Vol. 6 (1) , 3
Open AccessDevelopment of Integrated Electrocoagulation-Sedimentation (IECS) in Continuous Mode for Turbidity and Color Removal
The present work focused on the development and evaluation of a compact electrocoagulation (EC) reactor, combined between EC and clarifier processes in continuous modes for decolorization and turbidity removal, named the integrated electrocoagulation-sedimentation reactor (IECS). The experiments were firstly conducted in the four-liter batch column in order to optimize the EC configuration and operation condition. The removal kinetics were also investigated and predicted for kinetic correlations. After various optimization steps, the IECS reactor was conducted, consisting of EC and clarifier compartments. Liquid flow pattern in EC compartment was examined through resident time distribution technique for defining the number of EC units and divided baffles. In summary, four units of EC were placed in the EC compartment of the IECS reactor with 90% in the width of three baffles. Each EC unit had two pairs of aluminum electrode plats in monopolar arrangement with a 1.5 cm gap and required a current density of 13.5 mA/cm2. For the clarifier compartment, it was mainly designed based on the batch settling test for separating the precipitated particles. The treatment performance of the IECS reactor was tested at different liquid flows in order to reduce the pollutant to a certain level. For the individual condition, liquid flow rates of 3 and 1 L/min were defined for turbidity and color, respectively. If both pollutants are presented simultaneously, a liquid flow rate of 1–2 L/min can be used for decreasing turbidity from 250 to <20 NTU and color from 6000 to <300 ADMI.
- Open Access
Effective Analysis of Different Gas Diffusers on Bubble Hydrodynamics in Bubble Column and Airlift Reactors towards Mass Transfer Enhancement
Even bubble column reactors (BCR) and airlift reactors (ALR) have been developed in terms of various related aspects towards mass transfer enhancement, the effective analysis of gas diffuser types on mass transfer and gas–liquid hydrodynamic characteristics is still limited. Therefore, the present study aims to analyze the relative effect of different types of air diffusers on bubble hydrodynamics and mass transfer performance to understand their behaviors and define the best type. The experiments were conducted by varying different diffuser types, reactor types (BCR and ALR), and superficial gas velocity (Vg) (0.12 to 1.00 cm/s). Five air diffusers including commercial fine sand (F-sand) and coarse sand (C-sand) diffusers, and acrylic perforated diffusers with orifice sizes of 0.3 mm (H-0.3), 0.6 mm (H-0.6), and 1.2 mm (H-1.2), were used in this study. For every condition, it was analyzed in terms of bubble hydrodynamics and oxygen mass transfer coefficient (KLa). Lastly, the selected diffusers that provided the highest KLa coefficient were evaluated with a solid media addition case. The results of both reactor classes showed that F-sand, the smallest orifice diffuser, showed the smallest air bubbles (3.14–4.90 mm) compared to other diffusers, followed by C-sand, which larger about 22–28% on average than F-sand. ALR exhibited a better ability to maintain smaller bubbles than BCR. Moreover, F-sand and C-sand diffusers showed a slower rising velocity through their smaller bubbles and the tiny bubble recirculation in ALR. Using F-sand in ALR, the rising velocity is about 1.60–2.58 dm/s, which is slower than that in BCR about 39–54%. F-sand and C-sand were also found as the significant diffusers in terms of interfacial area and gas hold-up. Then, the KLa coefficient was estimated in every diffuser and reactor under the varying of Vg. Up to 270% higher KLa value was achieved from the use of F-sand and C-sand compared to other types due to their smaller bubbles generated/maintained and longer bubble retention time through slower rising velocity. After adding 10% ring shape plastic media into the reactors with F-sand and C-sand diffusers, a better performance was achieved in terms of KLa coefficient (up to 39%) as well as gas hold-up and liquid mixing. Lastly, ALR also had a larger portion of mixed flow pattern than BCR. This eventually promoted mass transfer by enhancing the mixed flow regime.
Open AccessEffective Analysis of Different Gas Diffusers on Bubble Hydrodynamics in Bubble Column and Airlift Reactors towards Mass Transfer Enhancement
Even bubble column reactors (BCR) and airlift reactors (ALR) have been developed in terms of various related aspects towards mass transfer enhancement, the effective analysis of gas diffuser types on mass transfer and gas–liquid hydrodynamic characteristics is still limited. Therefore, the present study aims to analyze the relative effect of different types of air diffusers on bubble hydrodynamics and mass transfer performance to understand their behaviors and define the best type. The experiments were conducted by varying different diffuser types, reactor types (BCR and ALR), and superficial gas velocity (Vg) (0.12 to 1.00 cm/s). Five air diffusers including commercial fine sand (F-sand) and coarse sand (C-sand) diffusers, and acrylic perforated diffusers with orifice sizes of 0.3 mm (H-0.3), 0.6 mm (H-0.6), and 1.2 mm (H-1.2), were used in this study. For every condition, it was analyzed in terms of bubble hydrodynamics and oxygen mass transfer coefficient (KLa). Lastly, the selected diffusers that provided the highest KLa coefficient were evaluated with a solid media addition case. The results of both reactor classes showed that F-sand, the smallest orifice diffuser, showed the smallest air bubbles (3.14–4.90 mm) compared to other diffusers, followed by C-sand, which larger about 22–28% on average than F-sand. ALR exhibited a better ability to maintain smaller bubbles than BCR. Moreover, F-sand and C-sand diffusers showed a slower rising velocity through their smaller bubbles and the tiny bubble recirculation in ALR. Using F-sand in ALR, the rising velocity is about 1.60–2.58 dm/s, which is slower than that in BCR about 39–54%. F-sand and C-sand were also found as the significant diffusers in terms of interfacial area and gas hold-up. Then, the KLa coefficient was estimated in every diffuser and reactor under the varying of Vg. Up to 270% higher KLa value was achieved from the use of F-sand and C-sand compared to other types due to their smaller bubbles generated/maintained and longer bubble retention time through slower rising velocity. After adding 10% ring shape plastic media into the reactors with F-sand and C-sand diffusers, a better performance was achieved in terms of KLa coefficient (up to 39%) as well as gas hold-up and liquid mixing. Lastly, ALR also had a larger portion of mixed flow pattern than BCR. This eventually promoted mass transfer by enhancing the mixed flow regime.
- Open Access
- 8 September 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10071
A Survey of Household Water Use and Groundwater Quality Index Assessment in a Rural Community of Cambodia
To propose an efficient system for addressing water scarcity in a rural area through groundwater use, the information on water consumption and interpretation of groundwater quality are essential for estimating the optimal preparation of the comprehensive water system. Hence, this study aimed to estimate the current household domestic water consumption and groundwater quality index of currently accessed wells in a small rural community of Preyveng province, Cambodia as a practical and beneficial as well as a model for the water resource sector in rural areas. The questionnaire survey was designed as the main instrument for collecting the household water use as face-to-face interviews. The result showed that the average daily water consumption in the Preal commune is about 71 L per capita, which is almost two times lower than the minimum water quantity recommended by the World Health Organization (WHO), 150 L/day per capita. Moreover, 100% of the households in this commune heavily rely on groundwater wells for domestic water use and more than 50% confirmed that they used raw groundwater as drinking water without a proposer treatment system. Approximately 70% of the people in Preal wishes to have a clean water supply and more than 80% of the household had a positive willingness to pay for clean water supply. In terms of groundwater quality in the Preal commune, it is mainly contaminated by iron, arsenic, fluoride, and manganese, which are mainly associated with human health effects from daily consumption. About 75% of groundwater wells are presented in poor conditions and were unsuitable for drinking purposes. Lastly, the suitable water treatment and supply should be considered in order to reduce the effects on people’s health as well as to improve living conditions.
- 8 September 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10071
Open AccessA Survey of Household Water Use and Groundwater Quality Index Assessment in a Rural Community of Cambodia
To propose an efficient system for addressing water scarcity in a rural area through groundwater use, the information on water consumption and interpretation of groundwater quality are essential for estimating the optimal preparation of the comprehensive water system. Hence, this study aimed to estimate the current household domestic water consumption and groundwater quality index of currently accessed wells in a small rural community of Preyveng province, Cambodia as a practical and beneficial as well as a model for the water resource sector in rural areas. The questionnaire survey was designed as the main instrument for collecting the household water use as face-to-face interviews. The result showed that the average daily water consumption in the Preal commune is about 71 L per capita, which is almost two times lower than the minimum water quantity recommended by the World Health Organization (WHO), 150 L/day per capita. Moreover, 100% of the households in this commune heavily rely on groundwater wells for domestic water use and more than 50% confirmed that they used raw groundwater as drinking water without a proposer treatment system. Approximately 70% of the people in Preal wishes to have a clean water supply and more than 80% of the household had a positive willingness to pay for clean water supply. In terms of groundwater quality in the Preal commune, it is mainly contaminated by iron, arsenic, fluoride, and manganese, which are mainly associated with human health effects from daily consumption. About 75% of groundwater wells are presented in poor conditions and were unsuitable for drinking purposes. Lastly, the suitable water treatment and supply should be considered in order to reduce the effects on people’s health as well as to improve living conditions.