    Performance Analysis of Overcurrent Protection under Corrupted Sampled Value Frames: A Hardware-in-the-Loop Approach

    by Ângelo Felipe Sartori, Adriano Peres de Morais, Ulisses Chemin Netto, Diomar Adonis Copetti Lima, Daniel Pinheiro Bernardon, Wagner Seizo Hokama

    The IEC 61850 standard aims at digitization substations and provides interoperability between various Intelligent Electronic Device vendors. The digitization process is accompanied by several challenges related to data transmission on the ethernet network and the protection behavior under these conditions. Among the challenges, we can mention packet loss, delay, and duplicate frame, which occurs when the merging units (publisher) transmit the sampled values and, for some reason, these packets do not reach the subscriber or are duplicated. Nowadays, most Intelligent Electronic Device manufacturers block the protection function when some sampled value packets are corrupted. The effects of blocking protection when packet loss occurs under normal operating conditions do not cause significant problems. However, when a fault occurs, the corrupted packets can cause a delay in fault clearance, causing even more damage to the grid. The purpose of this article is to present the effects of corrupted sampled values on the performance of overcurrent protection. All the evaluations were performed in real time using the hardware-in-loop simulation approach with a commercial Intelligent Electronic Device. The OP5700 hardware platform from OPAL-RT, with the library “IEC 61850 Data Integrity Manipulation”, was used. The results show that corrupted sampled value frames affect the functioning of the protections.


  • Open Access

    Review of Bus Differential Protection Using IEC 61850

    by Diomar A. C. Lima, Daniel P. Bernardon, Adriano P. Morais, Aécio L. Oliveira, Wagner S. Hokama, Júlia B. R. Conceição, Ângelo F. Sartori

    The electrical power system is susceptible to several faults, which can cause the system to malfunction. Among these, the ones that occur in the busbars of substations stand out. The main bus of a substation can concentrate a large amount of power and many derivations to service electrical loads, making it an element of high importance for the reliability of the system. Although the buses have a low incidence of faults, they are considered critical elements of the electrical power system, as their operating output can cause a large number of forced outages. This situation makes the protection of this component of paramount importance. There are currently two widely used bus differential protection techniques: high-impedance and low-impedance bus differential protection. The second technique is more commonly used due to the possibility of sharing current transformers (CTs). However, the high cost and greater requirements for maintenance makes the differential protection of busbars in distribution or sub-transmission substations unfeasible. With the advent and implementation of the IEC 61850 standard, modern protection systems based on this standard offer significant advantages, such as lower expenses with installation, wiring, commissioning and maintenance; adaptable bus configuration; use of different CT ratios; considerably minimized susceptibility to CT saturation; lower risks of open secondary CT circuits and viability of implantation in distribution substations. The objective of this review is to present an overview of the works found in the literature on substation busbar differential protection, considering classical methods and those based on the IEC 61850 standard.