Jungwon Rachael R. Ahn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jungwon Rachael R. Ahn has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Leah Feuerstahler
Fordham University
2 shared publications - Christopher Samouce
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA
1 shared publication Daniel Lorenzi
Fordham University, Bronx, USA
1 shared publication- Hannah Kavelak
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA
1 shared publication Jay Plourde
Fordham University, Bronx, USA
1 shared publication- Mayank S. Kotadia
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, USA
1 shared publication
Latest Publications
- 11 April 2026
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (5) , 2194-2203
Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion
Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.
- 11 April 2026
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (5) , 2194-2203
Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion
Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.
- 24 November 2023
- Published by Springer Nature in Behaviormetrika
- Vol. 51 (1) , 99-123
On the monotonicity of the residual heteroscedasticity item response model
- 24 November 2023
- Published by Springer Nature in Behaviormetrika
- Vol. 51 (1) , 99-123
On the monotonicity of the residual heteroscedasticity item response model
- 23 July 2021
- Published by Springer Nature
- p. 417-427
Diagnostic Classification Using a Polytomous Measure of Korean Organizational Commitment
- 23 July 2021
- Published by Springer Nature
- p. 417-427
Diagnostic Classification Using a Polytomous Measure of Korean Organizational Commitment