Christopher Samouce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christopher Samouce has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Aidan Mather
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, USA
1 shared publicationGonzalo J. Acosta
Division of Endocrinology, Diabetes and Metabolism, University of Florida College of Medicine, Gainesville, USA
1 shared publication- Hannah Kavelak
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA
1 shared publication Joseph Zachary
Department of Radiology, University of Florida College of Medicine, Gainesville, USA
1 shared publication- Jungwon Rachael R. Ahn
Affiliated as adjunct in the School of Human Development and Organizational Studies in Education, University of Florida College of Education, Gainesville, FL, USA
1 shared publication - Mayank S. Kotadia
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, USA
1 shared publication
Latest Publications
- 11 April 2026
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (5) , 2194-2203
Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion
Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.
- 11 April 2026
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (5) , 2194-2203
Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion
Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.
- 11 March 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- p. 1-8
Mixed reality simulator for ultrasound-guided thyroid nodule radiofrequency ablation: development and technical validation
Purpose Ultrasound-guided radiofrequency ablation (RFA) of benign thyroid nodules is an effective, minimally invasive alternative to surgery but has a steep learning curve and limited formal training options. Toward addressing this gap, we developed a mixed reality simulator for thyroid nodule RFA. Methods We implemented a real-time, voxel-based heat-transfer model of a thyroid nodule that computes temperature, thermal damage, and temperature-dependent impedance within a mixed reality simulator. The model was calibrated and verified with published RFA data from a thermal property-matched thyroid phantom and validated against published ex vivo lesion volumes. The simulator provides configurable nodule size and location, renders RFA ultrasound artifacts and lesion visualization, computes quantitative ablation metrics, and includes an interactive virtual RFA generator interface. Results Simulated temperature–time curves matched phantom sensor readings with a root mean square error of 1.4 °C. Simulated lesion volumes were within − 7.3% to + 0.9% of the ex vivo reference across 1.0–0.125 mm3 voxel volumes and lesion aspect ratios were lower by 4.7–10.5%. In a post-use survey, a single expert clinician rated visual realism, feedback fidelity, and training utility favorably. Conclusion The simulator closely reproduced phantom temperature profiles and ex vivo lesion sizes. Its architecture is configurable and extensible to other organs and thermal ablation modalities. Formal educational studies are warranted to evaluate training effectiveness of the simulator.
- 11 March 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- p. 1-8
Mixed reality simulator for ultrasound-guided thyroid nodule radiofrequency ablation: development and technical validation
Purpose Ultrasound-guided radiofrequency ablation (RFA) of benign thyroid nodules is an effective, minimally invasive alternative to surgery but has a steep learning curve and limited formal training options. Toward addressing this gap, we developed a mixed reality simulator for thyroid nodule RFA. Methods We implemented a real-time, voxel-based heat-transfer model of a thyroid nodule that computes temperature, thermal damage, and temperature-dependent impedance within a mixed reality simulator. The model was calibrated and verified with published RFA data from a thermal property-matched thyroid phantom and validated against published ex vivo lesion volumes. The simulator provides configurable nodule size and location, renders RFA ultrasound artifacts and lesion visualization, computes quantitative ablation metrics, and includes an interactive virtual RFA generator interface. Results Simulated temperature–time curves matched phantom sensor readings with a root mean square error of 1.4 °C. Simulated lesion volumes were within − 7.3% to + 0.9% of the ex vivo reference across 1.0–0.125 mm3 voxel volumes and lesion aspect ratios were lower by 4.7–10.5%. In a post-use survey, a single expert clinician rated visual realism, feedback fidelity, and training utility favorably. Conclusion The simulator closely reproduced phantom temperature profiles and ex vivo lesion sizes. Its architecture is configurable and extensible to other organs and thermal ablation modalities. Formal educational studies are warranted to evaluate training effectiveness of the simulator.