Samara Franco da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Samara Franco da Silva has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Camila Pontes Custódio
Department of Prothesis, School of Dentistry University of São Paulo São Paulo Brazil
2 shared publications - Carlos Eduardo Francci
Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo (FO-USP), São Paulo 05508-000, SP, Brazil
2 shared publications Mylena de Araújo Régis
Department of Biomaterials, School of Dentistry, University of São Paulo, Sao Paulo, Brazil
2 shared publications- Paulo Francisco Cesar
Universidade de São Paulo, Brazil
2 shared publications Carlos Eduardo Francci
Department of Biomaterials and Oral Biology, School of Dentistry University of São Paulo São Paulo Brazil
1 shared publication- Heitor Marques Honório
Department of Pediatric Dentistry, Orthodontics and Community Health, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 23 August 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Translucency Changes of Ceramic Veneers After Aging When Cemented on Substrates With Different Saturation: Effect of Ceramic Translucency and Resin Cement Shade
Objective: To evaluate the effect of ceramic translucency and resin cement shade on the translucency alteration after aging over different substrates. Methods: Sixty specimens were divided into 12 groups ( n = 5) composed of lithium disilicate (IPS e.max CAD, Ivoclar Vivadent) in three translucencies (HT, MT, LT). The 0.5 mm thick specimens were cemented with Variolink Esthetic LC (Ivoclar Vivadent) Light+ (L+) and Neutral (N) over resin substrates A1 and A4. Samples were subjected to 20,000 aging thermocycles, alternating 55°C–5°C (30 s). Spectral reflectance was measured using a spectrophotometer (CM‐3700d—Konica Minolta) at four intervals: before aging (t0) and after 10,000 (t10), 15,000 (t15), and 20,000 (t20) cycles. The Translucency Parameter (TP 00 ) and the ΔTP 00 were calculated. The thresholds for translucency perceptibility (TPT 00 ) and acceptability (TAT 00 ) were set at 0.62 and 2.62, respectively. Statistical analysis was performed using four‐way repeated measures ANOVA and Tukey's post hoc test ( α = 0.05). Results: Aging time, ceramic translucency, resin cement color and substrate saturation had a significant effect ( p < 0.001) on TP 00 . While TP 00 values declined across all groups, the lowest values for each measurement moment were consistently observed in the LTL+ groups [1.70 (t0) to 0.90 (t20)]. All ΔTP 00 values remained below the acceptability threshold (TAT = 2.62). Conclusion: Aging resulted in a generalized decrease in translucency across all groups, particularly over lighter substrates and when using chromatic resin cement. However, no clinically unacceptable alterations were observed. Clinical Significance: Clinicians should select materials based on the balance between initial masking and long‐term stability. For dark substrates, LT ceramics ensure consistent optical stability during aging, regardless of the resin cement shade. While combining translucent ceramics (HT/MT) with chromatic resin cements is an effective strategy for initial masking, clinicians must be aware that ceramic translucency is the primary factor controlling the final optical outcome over time.
- 23 August 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessTranslucency Changes of Ceramic Veneers After Aging When Cemented on Substrates With Different Saturation: Effect of Ceramic Translucency and Resin Cement Shade
Objective: To evaluate the effect of ceramic translucency and resin cement shade on the translucency alteration after aging over different substrates. Methods: Sixty specimens were divided into 12 groups ( n = 5) composed of lithium disilicate (IPS e.max CAD, Ivoclar Vivadent) in three translucencies (HT, MT, LT). The 0.5 mm thick specimens were cemented with Variolink Esthetic LC (Ivoclar Vivadent) Light+ (L+) and Neutral (N) over resin substrates A1 and A4. Samples were subjected to 20,000 aging thermocycles, alternating 55°C–5°C (30 s). Spectral reflectance was measured using a spectrophotometer (CM‐3700d—Konica Minolta) at four intervals: before aging (t0) and after 10,000 (t10), 15,000 (t15), and 20,000 (t20) cycles. The Translucency Parameter (TP 00 ) and the ΔTP 00 were calculated. The thresholds for translucency perceptibility (TPT 00 ) and acceptability (TAT 00 ) were set at 0.62 and 2.62, respectively. Statistical analysis was performed using four‐way repeated measures ANOVA and Tukey's post hoc test ( α = 0.05). Results: Aging time, ceramic translucency, resin cement color and substrate saturation had a significant effect ( p < 0.001) on TP 00 . While TP 00 values declined across all groups, the lowest values for each measurement moment were consistently observed in the LTL+ groups [1.70 (t0) to 0.90 (t20)]. All ΔTP 00 values remained below the acceptability threshold (TAT = 2.62). Conclusion: Aging resulted in a generalized decrease in translucency across all groups, particularly over lighter substrates and when using chromatic resin cement. However, no clinically unacceptable alterations were observed. Clinical Significance: Clinicians should select materials based on the balance between initial masking and long‐term stability. For dark substrates, LT ceramics ensure consistent optical stability during aging, regardless of the resin cement shade. While combining translucent ceramics (HT/MT) with chromatic resin cements is an effective strategy for initial masking, clinicians must be aware that ceramic translucency is the primary factor controlling the final optical outcome over time.
- 6 January 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (4) , 357-365
Impact of the resin cement opacity on the final color of conservative ceramic restorations and on its ability to mask substrates of different saturations
- 6 January 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (4) , 357-365
Impact of the resin cement opacity on the final color of conservative ceramic restorations and on its ability to mask substrates of different saturations
- 27 November 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 36 (5) , 761-769
The capacity of conservative preparations for lithium disilicate glass–ceramic laminates luted with different resin cements to mask different substrate shades: A minimally invasive esthetic approach
Objective: Demonstrate the ability of 0.5 mm thickness lithium disilicate laminates associated with resin cement to mask different substrate saturations.Methods: 60 specimens (n = 5) were prepared with CAD/CAM lithium disilicate glass–ceramic IPS e.max CAD, 0.5 mm thick, in three degrees of translucency (HT, MT and LT); cemented by Variolink Esthetic LC Light+ (L) and Neutral (N) on composite resin substrates A1 and A4 shades. Color measurements were performed by a spectrophotometer (CM‐3700d ‐Konica Minolta). The L*, a*, b* parameters of the tri‐layer structure (laminate/ resin cement/ substrate) were used to calculate color difference () by CIEDE2000 formula and Translucency Parameter (). This study adopted = 0.8, as perceptibility threshold (PT), and = 1.8, as acceptability threshold (AT). Statistical analyses were performed by one‐way ANOVA and Tukey tests (a = 0.05).Results: Color difference between resin cement shades showed statistical differences (p < 0.0001) and > 1.8 for all groups. Color difference between substrates saturations showed a significant statistical difference (p < 0.0001) and values above AT for all groups. The demonstrated significant statistical differences (p < 0.0001). The LTL combination, the opaquest set, showed the smallest values between substrate shades differences, however, above AT.Conclusion: The translucency of the lithium disilicate, the substrate saturation and the resin cement opacity influenced final color of restoration. The ceramic translucency impact on final color was reduced by opaque resin cement. Furthermore, the LT lithium disilicate and the Light+ resin cement reduced the translucency of the restoration, contributing to mask saturated substrate.Clinical Relevance: This study shows the influence of conservative lithium disilicate laminates with different degrees of translucency associated with resin cement on final color of saturated substrate restorations. A minimally invasive esthetic protocol for masking substrates is demonstrated by associating low translucency ceramic laminates and opaque resin cement.
- 27 November 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 36 (5) , 761-769
The capacity of conservative preparations for lithium disilicate glass–ceramic laminates luted with different resin cements to mask different substrate shades: A minimally invasive esthetic approach
Objective: Demonstrate the ability of 0.5 mm thickness lithium disilicate laminates associated with resin cement to mask different substrate saturations.Methods: 60 specimens (n = 5) were prepared with CAD/CAM lithium disilicate glass–ceramic IPS e.max CAD, 0.5 mm thick, in three degrees of translucency (HT, MT and LT); cemented by Variolink Esthetic LC Light+ (L) and Neutral (N) on composite resin substrates A1 and A4 shades. Color measurements were performed by a spectrophotometer (CM‐3700d ‐Konica Minolta). The L*, a*, b* parameters of the tri‐layer structure (laminate/ resin cement/ substrate) were used to calculate color difference () by CIEDE2000 formula and Translucency Parameter (). This study adopted = 0.8, as perceptibility threshold (PT), and = 1.8, as acceptability threshold (AT). Statistical analyses were performed by one‐way ANOVA and Tukey tests (a = 0.05).Results: Color difference between resin cement shades showed statistical differences (p < 0.0001) and > 1.8 for all groups. Color difference between substrates saturations showed a significant statistical difference (p < 0.0001) and values above AT for all groups. The demonstrated significant statistical differences (p < 0.0001). The LTL combination, the opaquest set, showed the smallest values between substrate shades differences, however, above AT.Conclusion: The translucency of the lithium disilicate, the substrate saturation and the resin cement opacity influenced final color of restoration. The ceramic translucency impact on final color was reduced by opaque resin cement. Furthermore, the LT lithium disilicate and the Light+ resin cement reduced the translucency of the restoration, contributing to mask saturated substrate.Clinical Relevance: This study shows the influence of conservative lithium disilicate laminates with different degrees of translucency associated with resin cement on final color of saturated substrate restorations. A minimally invasive esthetic protocol for masking substrates is demonstrated by associating low translucency ceramic laminates and opaque resin cement.