Xueqin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xueqin Zhang has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Yujun Guo
School of Electrical Engineering Southwest Jiaotong University Chengdu China
40 shared publications - Guangning Wu
Southwest Jiaotong University
32 shared publications - Song Xiao
Southwest Jiaotong University
22 shared publications - Chenguang Yang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
8 shared publications Guangning Wu
School of Electrical Engineering Southwest Jiaotong University Chengdu China
7 shared publications- Guoqiang Gao
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
7 shared publications
Latest Publications
- Open Access
Fault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil Conditions
The transient responses of GIL-overhead line hybrid transmission systems during lightning and short-circuit faults directly affect insulation performance, equipment thermal stability, and grounding safety, particularly under high-resistivity soil conditions. However, research on enclosure fault current distribution and its spatial distribution of grounding currents along multipoint-grounded GIL systems under such conditions remains limited. To address this issue, an electromagnetic transient model of a 500 kV GIL-overhead line hybrid transmission system is established to investigate fault responses in high-resistivity soil conditions. The effects of short-circuit types, fault locations, and enclosure grounding spacing on grounding current distribution are analyzed. The results indicate that increased grounding impedance aggravates lightning-induced transient overvoltage. Under short-circuit faults, grounding currents along the GIL exhibit a U-shaped distribution, characterized by higher currents at both ends and lower currents in the middle. The peak local grounding current reaches 42.22 kA during a single-phase-to-ground fault in the middle section of the GIL. This study provides a basis for identifying critical grounding points, selecting adverse fault conditions, and comparing grounding configurations in hybrid transmission systems, as well as for grounding-lead thermal stability verification and grounding safety assessment.
Open AccessFault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil Conditions
The transient responses of GIL-overhead line hybrid transmission systems during lightning and short-circuit faults directly affect insulation performance, equipment thermal stability, and grounding safety, particularly under high-resistivity soil conditions. However, research on enclosure fault current distribution and its spatial distribution of grounding currents along multipoint-grounded GIL systems under such conditions remains limited. To address this issue, an electromagnetic transient model of a 500 kV GIL-overhead line hybrid transmission system is established to investigate fault responses in high-resistivity soil conditions. The effects of short-circuit types, fault locations, and enclosure grounding spacing on grounding current distribution are analyzed. The results indicate that increased grounding impedance aggravates lightning-induced transient overvoltage. Under short-circuit faults, grounding currents along the GIL exhibit a U-shaped distribution, characterized by higher currents at both ends and lower currents in the middle. The peak local grounding current reaches 42.22 kA during a single-phase-to-ground fault in the middle section of the GIL. This study provides a basis for identifying critical grounding points, selecting adverse fault conditions, and comparing grounding configurations in hybrid transmission systems, as well as for grounding-lead thermal stability verification and grounding safety assessment.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (5) , 3891-3900
An Advanced Detection Method for Assessing Aging State of Composite Insulators Under Pollution Cover
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (5) , 3891-3900
An Advanced Detection Method for Assessing Aging State of Composite Insulators Under Pollution Cover
- Open Access
System-Level Dynamic Modeling and Cross-Domain Disturbance Propagation of an Electricity–Hydrogen–Heat Coupling Subsystem for Integrated Transportation Hubs
Integrated transportation hubs are characterized by fast-varying and strongly coupled electricity, hydrogen-refueling, and thermal demands driven by traffic activities. To characterize their short-term dynamic interactions, this paper develops a compact system-level model of a core electricity–hydrogen–heat coupling subsystem comprising a PEM electrolyzer, a hydrogen storage tank, a fuel cell, and a thermal side. Power- and temperature-dependent off-design models are established for the PEM electrolyzer and fuel cell, while a lumped-parameter thermodynamic model with real-gas correction is developed for the hydrogen storage tank. The electrolyzer and fuel-cell models achieve calibration MAPEs of 0.39% and approximately 0.81%, respectively, against published reference data. Two typical disturbance scenarios are then investigated. Under a 30 kW electrical-load step, the grid-power deviation is reduced from a peak of approximately 29.4 kW to about 9.1 kW, while the hydrogen-refueling-demand disturbance produces only a minor thermal-side temperature variation. The results reveal distinct propagation magnitudes and time-scale characteristics across the electrical, hydrogen, and thermal domains. The proposed framework provides a compact and physically interpretable tool for short-term cross-domain dynamic analysis of integrated transportation hubs.
Open AccessSystem-Level Dynamic Modeling and Cross-Domain Disturbance Propagation of an Electricity–Hydrogen–Heat Coupling Subsystem for Integrated Transportation Hubs
Integrated transportation hubs are characterized by fast-varying and strongly coupled electricity, hydrogen-refueling, and thermal demands driven by traffic activities. To characterize their short-term dynamic interactions, this paper develops a compact system-level model of a core electricity–hydrogen–heat coupling subsystem comprising a PEM electrolyzer, a hydrogen storage tank, a fuel cell, and a thermal side. Power- and temperature-dependent off-design models are established for the PEM electrolyzer and fuel cell, while a lumped-parameter thermodynamic model with real-gas correction is developed for the hydrogen storage tank. The electrolyzer and fuel-cell models achieve calibration MAPEs of 0.39% and approximately 0.81%, respectively, against published reference data. Two typical disturbance scenarios are then investigated. Under a 30 kW electrical-load step, the grid-power deviation is reduced from a peak of approximately 29.4 kW to about 9.1 kW, while the hydrogen-refueling-demand disturbance produces only a minor thermal-side temperature variation. The results reveal distinct propagation magnitudes and time-scale characteristics across the electrical, hydrogen, and thermal domains. The proposed framework provides a compact and physically interpretable tool for short-term cross-domain dynamic analysis of integrated transportation hubs.
- 2 September 2026
- Published by Springer Nature
- p. 49-57
Research on Performance Evaluation and Optimization of Composite Insulators in High-Altitude Strong Ultraviolet Environment
- 2 September 2026
- Published by Springer Nature
- p. 49-57
Research on Performance Evaluation and Optimization of Composite Insulators in High-Altitude Strong Ultraviolet Environment
- Open Access
- 1 September 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
Study on Raindrop Dynamic Behaviour and Its Impact on Insulator Flashover Characteristics Under Airflow Synergy
The synergistic effect of airflow on rainfall behaviour significantly impacts the flashover probability of insulators. This study combines experiments and simulations to investigate the influence of raindrop dynamic behaviour, shed structures and rainfall conditions on flashover characteristics under airflow conditions. High‐speed cameras capture the dynamic behaviour of raindrops along the shed eave and their impact on the development of flashover. Meanwhile, finite element simulations analyse the role of shed structures in regulating airflow characteristics, raindrop dynamic behaviour and electric field distribution. The results indicate that airflow‐induced changes in raindrop behaviour exacerbate inter‐shed electric field distortion. Raindrop stretching, fragmentation, recombination and bridging behaviours accelerate the formation of conductive paths, significantly influencing arc generation, expansion, strengthening, drifting and extinction. Roof insulators with larger shed spacing and wider shed skirts demonstrate better resistance to rain‐induced flashover by suppressing raindrop accumulation and alleviating electric field distortion. This study reveals the synergistic mechanism among raindrop dynamic behaviour, electric field distortion and flashover characteristics, offering optimisation guidelines for insulator selection under extreme rainfall conditions for high‐speed trains.
- 1 September 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
Open AccessStudy on Raindrop Dynamic Behaviour and Its Impact on Insulator Flashover Characteristics Under Airflow Synergy
The synergistic effect of airflow on rainfall behaviour significantly impacts the flashover probability of insulators. This study combines experiments and simulations to investigate the influence of raindrop dynamic behaviour, shed structures and rainfall conditions on flashover characteristics under airflow conditions. High‐speed cameras capture the dynamic behaviour of raindrops along the shed eave and their impact on the development of flashover. Meanwhile, finite element simulations analyse the role of shed structures in regulating airflow characteristics, raindrop dynamic behaviour and electric field distribution. The results indicate that airflow‐induced changes in raindrop behaviour exacerbate inter‐shed electric field distortion. Raindrop stretching, fragmentation, recombination and bridging behaviours accelerate the formation of conductive paths, significantly influencing arc generation, expansion, strengthening, drifting and extinction. Roof insulators with larger shed spacing and wider shed skirts demonstrate better resistance to rain‐induced flashover by suppressing raindrop accumulation and alleviating electric field distortion. This study reveals the synergistic mechanism among raindrop dynamic behaviour, electric field distortion and flashover characteristics, offering optimisation guidelines for insulator selection under extreme rainfall conditions for high‐speed trains.
- Open Access
Multi-Time-Scale Cloud–Edge–Terminal Energy Management of an Electricity–Hydrogen–Thermal System for Rail Transit Hub Non-Traction Loads
Rail stations have non-traction electricity and heat demands, requiring coordinated renewable generation, storage, and conversion. We develop a cloud–edge–terminal energy-management framework for an electricity–hydrogen–thermal system. A 24 h mixed-integer linear programming model schedules grid import, photovoltaic (PV) generation, battery and thermal storage, electrolysis, hydrogen compression and storage, and fuel-cell and heat-pump operation. Hydrogen inventory is represented by stored hydrogen mass, with tank pressure linked to hydrogen density through a pressure–density relation. We compare three systems: hydrogen-free, hydrogen-integrated, and hydrogen-free with electrically equivalent battery storage. Hourly schedules map 150 capacity-equivalent virtual terminals for minute-level verification under operational and communication disturbances. Hydrogen integration reduces objective value by 1.06%, operating cost by 0.34%, and peak grid import by 6.89% relative to hydrogen-free operation but increases daily grid electricity purchase and CO2 emissions by approximately 3.09%. Sensitivity analyses show stronger benefits at higher PV penetration, negligible gains from tank-volume expansion beyond the storage range, and electrolyzer power as the constraint on renewable absorption at high PV capacities. Verification achieves a 98.503% average command–delivery success rate, a steady-state grid import error below 1 kW, and 2 min to self-heal faults. Hydrogen improves peak shaving and intertemporal energy shifting, whereas total electricity use and emissions depend on renewable availability and conversion limits.
Open AccessMulti-Time-Scale Cloud–Edge–Terminal Energy Management of an Electricity–Hydrogen–Thermal System for Rail Transit Hub Non-Traction Loads
Rail stations have non-traction electricity and heat demands, requiring coordinated renewable generation, storage, and conversion. We develop a cloud–edge–terminal energy-management framework for an electricity–hydrogen–thermal system. A 24 h mixed-integer linear programming model schedules grid import, photovoltaic (PV) generation, battery and thermal storage, electrolysis, hydrogen compression and storage, and fuel-cell and heat-pump operation. Hydrogen inventory is represented by stored hydrogen mass, with tank pressure linked to hydrogen density through a pressure–density relation. We compare three systems: hydrogen-free, hydrogen-integrated, and hydrogen-free with electrically equivalent battery storage. Hourly schedules map 150 capacity-equivalent virtual terminals for minute-level verification under operational and communication disturbances. Hydrogen integration reduces objective value by 1.06%, operating cost by 0.34%, and peak grid import by 6.89% relative to hydrogen-free operation but increases daily grid electricity purchase and CO2 emissions by approximately 3.09%. Sensitivity analyses show stronger benefits at higher PV penetration, negligible gains from tank-volume expansion beyond the storage range, and electrolyzer power as the constraint on renewable absorption at high PV capacities. Verification achieves a 98.503% average command–delivery success rate, a steady-state grid import error below 1 kW, and 2 min to self-heal faults. Hydrogen improves peak shaving and intertemporal energy shifting, whereas total electricity use and emissions depend on renewable availability and conversion limits.
- Open Access
- 19 August 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (4) , 1021-1031
Pixel‐Level Inversion Assessment for Ageing of Composite Insulator Sheds of Power System
The polymeric materials used in insulator sheds are prone to ageing under different environmental conditions, which can lead to flashovers and grid outages. The ageing process in composite insulators primarily involves changes in the microscopic properties of the materials. Ageing levels were determined based on the hydrophobicity of artificially accelerated ageing samples, and spectral lines ranging from 400 to 1000 nm were analysed at various ageing stages. This study employed sample entropy as the objective function and used Beluga whale optimization to determine the optimal number of decomposition layers, K , and the penalty parameter, α , for the variational mode decomposition, thereby achieving effective denoising in the spectral domain. The channel attention mechanism was able to better extract ageing status information from the spectral bands. By employing a long short‐term memory network with an adaptively weighted squeeze‐and‐excitation network, a high global accuracy of 95.48% was attained, outperforming traditional classification models. This approach successfully addressed the challenge of low evaluation accuracy resulting from the high spectral line similarity observed in severely aged levels. The trained model enabled the visualisation of ageing distribution at the pixel level within the sheds' structure, overcoming difficulties associated with detecting microscopic ageing states and providing comprehensive assessments of composite insulators. This research study significantly contributes to ensuring the safe operation of power grids and offers valuable insights for guiding the material selection and design of composite insulators in diverse environments, thereby presenting promising applications in various fields of electrical equipment condition monitoring.
- 19 August 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (4) , 1021-1031
Open AccessPixel‐Level Inversion Assessment for Ageing of Composite Insulator Sheds of Power System
The polymeric materials used in insulator sheds are prone to ageing under different environmental conditions, which can lead to flashovers and grid outages. The ageing process in composite insulators primarily involves changes in the microscopic properties of the materials. Ageing levels were determined based on the hydrophobicity of artificially accelerated ageing samples, and spectral lines ranging from 400 to 1000 nm were analysed at various ageing stages. This study employed sample entropy as the objective function and used Beluga whale optimization to determine the optimal number of decomposition layers, K , and the penalty parameter, α , for the variational mode decomposition, thereby achieving effective denoising in the spectral domain. The channel attention mechanism was able to better extract ageing status information from the spectral bands. By employing a long short‐term memory network with an adaptively weighted squeeze‐and‐excitation network, a high global accuracy of 95.48% was attained, outperforming traditional classification models. This approach successfully addressed the challenge of low evaluation accuracy resulting from the high spectral line similarity observed in severely aged levels. The trained model enabled the visualisation of ageing distribution at the pixel level within the sheds' structure, overcoming difficulties associated with detecting microscopic ageing states and providing comprehensive assessments of composite insulators. This research study significantly contributes to ensuring the safe operation of power grids and offers valuable insights for guiding the material selection and design of composite insulators in diverse environments, thereby presenting promising applications in various fields of electrical equipment condition monitoring.
- 15 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
AC Flashover Characteristics of Roof Insulators with Fan-Shaped Non-Uniform Pollution under High-Speed Airflow Conditions
Roof-mounted high-voltage equipment operates under sustained high-speed airflow, leading to a pronounced non-uniform pollution distribution between the windward and leeward surfaces. The combined effects of high-speed airflow and fan-shaped non-uniform pollution significantly affect the AC flashover characteristics and arc development behavior of roof insulators, posing a potential risk to train operation. Therefore, AC flashover tests were conducted on roof insulators with different degrees of non-uniform pollution under high-speed airflow conditions. The results show that the arc is progressively detached from the polluted surface by forward airflow and follows a characteristic “blow-off – elongation – reattachment” evolution. With increasing airflow velocity, the flashover voltage first increases and then slightly decreases, while at low airflow velocities it is more sensitive to the degree of pollution non-uniformity.
- 15 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
AC Flashover Characteristics of Roof Insulators with Fan-Shaped Non-Uniform Pollution under High-Speed Airflow Conditions
Roof-mounted high-voltage equipment operates under sustained high-speed airflow, leading to a pronounced non-uniform pollution distribution between the windward and leeward surfaces. The combined effects of high-speed airflow and fan-shaped non-uniform pollution significantly affect the AC flashover characteristics and arc development behavior of roof insulators, posing a potential risk to train operation. Therefore, AC flashover tests were conducted on roof insulators with different degrees of non-uniform pollution under high-speed airflow conditions. The results show that the arc is progressively detached from the polluted surface by forward airflow and follows a characteristic “blow-off – elongation – reattachment” evolution. With increasing airflow velocity, the flashover voltage first increases and then slightly decreases, while at low airflow velocities it is more sensitive to the degree of pollution non-uniformity.
- 2 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 260
AC flashover characteristics and arc propagation path of roof insulators under non-uniform pollution
- 2 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 260
AC flashover characteristics and arc propagation path of roof insulators under non-uniform pollution
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Wind Pressure Distribution Characteristics and Multi-Objective Structural Optimization of High-Speed Train Roof Insulators Considering Shed Deformation
With the continuous increase in train speed, the influence of uneven wind pressure distribution on the surface of roof silicone rubber composite insulators on their insulation performance has become increasingly significant. To address the trade-off between improving wind pressure distribution and enhancing wind resistance performance of sheds under high-speed airflow, a multi-objective optimization method for roof silicone rubber composite insulators is proposed. First, the influence of shed deformation on wind pressure distribution is investigated by establishing a fluid-structure interaction (FSI) model. Then, the Pareto optimal solution set is obtained using Kriging surrogate model combined with the NSGA-II algorithm. Finally, the insulation and wind resistance performances are experimentally validated using 3D-printed roof insulators. Simulation results indicate that the maximum deformation occurs at the edge of the shed and increases exponentially with airflow speed. The deformation on the windward side is the most pronounced, and that of the large shed is greater than that of the small shed. The wind pressure distribution along the shed edge plays a dominant role in its deformation characteristics. When the airflow speed exceeds 80 m/s, the influence of shed deformation on the local wind pressure distribution should be considered. The optimized scheme increases the average wind pressure on the leeward side by more than 68.51% and reduces the maximum shed deformation by 19.74%. Experimental results further demonstrate that the optimized roof insulators exhibit a higher flashover voltage and significantly reduced shed shape variation, achieving a synergistic improvement in wind pressure distribution and wind resistance performance.
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Wind Pressure Distribution Characteristics and Multi-Objective Structural Optimization of High-Speed Train Roof Insulators Considering Shed Deformation
With the continuous increase in train speed, the influence of uneven wind pressure distribution on the surface of roof silicone rubber composite insulators on their insulation performance has become increasingly significant. To address the trade-off between improving wind pressure distribution and enhancing wind resistance performance of sheds under high-speed airflow, a multi-objective optimization method for roof silicone rubber composite insulators is proposed. First, the influence of shed deformation on wind pressure distribution is investigated by establishing a fluid-structure interaction (FSI) model. Then, the Pareto optimal solution set is obtained using Kriging surrogate model combined with the NSGA-II algorithm. Finally, the insulation and wind resistance performances are experimentally validated using 3D-printed roof insulators. Simulation results indicate that the maximum deformation occurs at the edge of the shed and increases exponentially with airflow speed. The deformation on the windward side is the most pronounced, and that of the large shed is greater than that of the small shed. The wind pressure distribution along the shed edge plays a dominant role in its deformation characteristics. When the airflow speed exceeds 80 m/s, the influence of shed deformation on the local wind pressure distribution should be considered. The optimized scheme increases the average wind pressure on the leeward side by more than 68.51% and reduces the maximum shed deformation by 19.74%. Experimental results further demonstrate that the optimized roof insulators exhibit a higher flashover voltage and significantly reduced shed shape variation, achieving a synergistic improvement in wind pressure distribution and wind resistance performance.