Chenguang Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chenguang Yang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Yujun Guo
School of Electrical Engineering Southwest Jiaotong University Chengdu China
9 shared publications - Guangning Wu
Southwest Jiaotong University
8 shared publications - Xueqin Zhang
Southwest Jiaotong University
8 shared publications Zihao Wang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
5 shared publicationsDalin Li
Southwest Jiaotong University, Chengdu, China
4 shared publications- Song Xiao
Southwest Jiaotong University
3 shared publications
Latest Publications
- 2 September 2026
- Published by Springer Nature
- p. 58-65
Characterization of Arc Development of Roof Insulators for High-Speed Trains
- 2 September 2026
- Published by Springer Nature
- p. 58-65
Characterization of Arc Development of Roof Insulators for High-Speed Trains
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. PP (08858977) , 1-10
The Effect of Airflow on the Flashover Voltage and Path of Roof Insulators
As the operating speed of high-speed trains continues to rise, roof insulators are subjected to strong airflow for prolonged periods, significantly influencing their discharge behavior. To investigate how airflow affects the flashover characteristics of roof insulators, this study conducts flashover voltage tests and captures discharge paths in a wind tunnel using a scaled model. Combined with computational fluid dynamics (CFD) simulations, the study systematically analyzes the leeward flow field at various inlet wind speeds and its effects on flashover paths and voltages. The results show that as wind speed increases, the flashover voltage initially rises, then decreases, and finally stabilizes. Meanwhile, the flashover path first moves away from the insulator and then approaches it, reflecting the nonlinear influence of the aerodynamic environment on both the arc path and flashover voltage. Airflow generates pronounced negative pressure and recirculation zones on the leeward side of the insulator. As wind speed increases, the negative pressure and recirculating flow intensify and move closer to the insulator surface, significantly altering the arc force direction and discharge path. At low wind speeds, the arc extends downstream and is blown away, whereas at high wind speeds, it is pulled toward the insulator by the recirculating flow. This causes the discharge path to elongate and then shorten, resulting in a corresponding rise followed by a decrease in flashover voltage. This study offers theoretical insights and practical guidance for optimizing insulator design in high-speed trains and understanding aerodynamic discharge mechanisms.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. PP (08858977) , 1-10
The Effect of Airflow on the Flashover Voltage and Path of Roof Insulators
As the operating speed of high-speed trains continues to rise, roof insulators are subjected to strong airflow for prolonged periods, significantly influencing their discharge behavior. To investigate how airflow affects the flashover characteristics of roof insulators, this study conducts flashover voltage tests and captures discharge paths in a wind tunnel using a scaled model. Combined with computational fluid dynamics (CFD) simulations, the study systematically analyzes the leeward flow field at various inlet wind speeds and its effects on flashover paths and voltages. The results show that as wind speed increases, the flashover voltage initially rises, then decreases, and finally stabilizes. Meanwhile, the flashover path first moves away from the insulator and then approaches it, reflecting the nonlinear influence of the aerodynamic environment on both the arc path and flashover voltage. Airflow generates pronounced negative pressure and recirculation zones on the leeward side of the insulator. As wind speed increases, the negative pressure and recirculating flow intensify and move closer to the insulator surface, significantly altering the arc force direction and discharge path. At low wind speeds, the arc extends downstream and is blown away, whereas at high wind speeds, it is pulled toward the insulator by the recirculating flow. This causes the discharge path to elongate and then shorten, resulting in a corresponding rise followed by a decrease in flashover voltage. This study offers theoretical insights and practical guidance for optimizing insulator design in high-speed trains and understanding aerodynamic discharge mechanisms.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (3) , 2195-2204
Aerodynamic and Electrical Characteristics of Roof Insulators With Wave-Shaped Structures
During high-speed train operation, further reducing aerodynamic drag is challenging due to the presence of the roof insulator. Optimizing the roof insulator aerodynamically has become a new focus in reducing drag for high-speed trains. This study proposes a wave-shaped core rod structure for the roof insulator to achieve further drag reduction in high-speed trains. A surrogate model replaces the computationally expensive simulations, and structural optimization is performed using a multi-population genetic algorithm. Given the highly nonlinear aerodynamic drag of the roof insulator, a fully connected neural network based on machine learning is chosen to build the surrogate model. Based on simulation results, the drag reduction mechanism of the optimized roof insulator structure is investigated. Finally, a flashover test is conducted on the optimized insulator to verify its insulation performance. The results show that the wave structure reduces aerodynamic drag by up to 18.8%. Additionally, the flashover voltage of the wave-shaped core rod insulator increases by 23.11% at a wind speed of 100 m/s. The aerodynamic performance of the roof insulator is improved while maintaining its insulation performance.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (3) , 2195-2204
Aerodynamic and Electrical Characteristics of Roof Insulators With Wave-Shaped Structures
During high-speed train operation, further reducing aerodynamic drag is challenging due to the presence of the roof insulator. Optimizing the roof insulator aerodynamically has become a new focus in reducing drag for high-speed trains. This study proposes a wave-shaped core rod structure for the roof insulator to achieve further drag reduction in high-speed trains. A surrogate model replaces the computationally expensive simulations, and structural optimization is performed using a multi-population genetic algorithm. Given the highly nonlinear aerodynamic drag of the roof insulator, a fully connected neural network based on machine learning is chosen to build the surrogate model. Based on simulation results, the drag reduction mechanism of the optimized roof insulator structure is investigated. Finally, a flashover test is conducted on the optimized insulator to verify its insulation performance. The results show that the wave structure reduces aerodynamic drag by up to 18.8%. Additionally, the flashover voltage of the wave-shaped core rod insulator increases by 23.11% at a wind speed of 100 m/s. The aerodynamic performance of the roof insulator is improved while maintaining its insulation performance.
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1400-1410
Impact of Contamination on AC Flashover Performance of Contact Network Insulators Under High-Fouling Tunnel Conditions
The semi-enclosed environment of railway tunnels intensifies the accumulation of natural contamination on insulating surfaces. However, the natural contamination and flashover characteristics of railway tunnel insulators are underexplored. This study investigates the accumulation of contamination on railway tunnel insulators, focusing on equivalent salt deposit density (ESDD), non-soluble deposit density (NSDD), the NSDD/ESDD ratio (KN/E), and contamination non-uniformity (K). The chemical composition, particle size, and insoluble components of contamination are also analyzed. Results show peak contamination at tunnel entrances/exits. ESDD ranges from 0.1 to 1.1 mg/cm2, and NSDD from 2 to 18 mg/cm2, with larger particles (>10 μm) concentrated at entrances/exits. Compared to other regions, the KN/E ratio inside the tunnel (1.7-23.4) is higher, and tunnel contamination is E level (nonuniformity KESDD: 1/2.19-1/1.44), while external contamination is typically B level due to rainfall. The study examines the effects of pressure, ESDD, and K on flashover voltage, with multi-factor ANOVA showing ESDD as the dominant factor, with the strongest interaction between ESDD and pressure. Compared to different shed parameters, the optimal S/L ratio for flashover performance ranges from 1.55 to 1.77, with larger ratios (1.77) suited for light pollution environments and smaller ratios (1.55) for heavy pollution. Additionally, insoluble components like metal oxides and carbon reduce flashover voltage and increase leakage current by shortening the creepage distance and enhancing conductivity and arc stability. These findings offer key insights for external insulation configuration, designing, and artificial contamination testing in high-altitude railway tunnels.
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1400-1410
Impact of Contamination on AC Flashover Performance of Contact Network Insulators Under High-Fouling Tunnel Conditions
The semi-enclosed environment of railway tunnels intensifies the accumulation of natural contamination on insulating surfaces. However, the natural contamination and flashover characteristics of railway tunnel insulators are underexplored. This study investigates the accumulation of contamination on railway tunnel insulators, focusing on equivalent salt deposit density (ESDD), non-soluble deposit density (NSDD), the NSDD/ESDD ratio (KN/E), and contamination non-uniformity (K). The chemical composition, particle size, and insoluble components of contamination are also analyzed. Results show peak contamination at tunnel entrances/exits. ESDD ranges from 0.1 to 1.1 mg/cm2, and NSDD from 2 to 18 mg/cm2, with larger particles (>10 μm) concentrated at entrances/exits. Compared to other regions, the KN/E ratio inside the tunnel (1.7-23.4) is higher, and tunnel contamination is E level (nonuniformity KESDD: 1/2.19-1/1.44), while external contamination is typically B level due to rainfall. The study examines the effects of pressure, ESDD, and K on flashover voltage, with multi-factor ANOVA showing ESDD as the dominant factor, with the strongest interaction between ESDD and pressure. Compared to different shed parameters, the optimal S/L ratio for flashover performance ranges from 1.55 to 1.77, with larger ratios (1.77) suited for light pollution environments and smaller ratios (1.55) for heavy pollution. Additionally, insoluble components like metal oxides and carbon reduce flashover voltage and increase leakage current by shortening the creepage distance and enhancing conductivity and arc stability. These findings offer key insights for external insulation configuration, designing, and artificial contamination testing in high-altitude railway tunnels.
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3669-3678
AC Pollution Flashover Characteristics and Altitude Correction of Train Roof Insulators at High Altitude
Roof insulators are essential equipment for the safe operation of the traction power supply system. When the train runs to high altitude, the roof insulator is completely exposed to the atmosphere. Affected by low air pressure and natural pollution, the insulation performance is significantly reduced, threatening the safety of train operation. Using the artificial climate simulation system, the AC pollution flashover characteristics of different types of roof insulators at an altitude of 498~4500m are studied. And the altitude correction method of flashover voltage is proposed. Finally, the follow-up research and suggestions for roof insulators at high altitude are given. The results show that the average values of the pollution characteristics impact index a of the FDZ and FS type roof insulators are 0.308 and 0.268 respectively, and the average values of the air pressure characteristics impact index n are 0.721 and 0.867 respectively. The smaller the insulator sheds spacing, the larger the proportion of air gap arc. And the lower the air pressure, the more serious the floating arc phenomenon. For every 1km increase in altitude, the average flashover voltages of FDZ and FS type roof insulators decrease by about 8.65% and 10.4%, respectively. The roof insulators with shed spacings of 30-35mm and shed combination of a large and two small are recommended at high altitudes.
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3669-3678
AC Pollution Flashover Characteristics and Altitude Correction of Train Roof Insulators at High Altitude
Roof insulators are essential equipment for the safe operation of the traction power supply system. When the train runs to high altitude, the roof insulator is completely exposed to the atmosphere. Affected by low air pressure and natural pollution, the insulation performance is significantly reduced, threatening the safety of train operation. Using the artificial climate simulation system, the AC pollution flashover characteristics of different types of roof insulators at an altitude of 498~4500m are studied. And the altitude correction method of flashover voltage is proposed. Finally, the follow-up research and suggestions for roof insulators at high altitude are given. The results show that the average values of the pollution characteristics impact index a of the FDZ and FS type roof insulators are 0.308 and 0.268 respectively, and the average values of the air pressure characteristics impact index n are 0.721 and 0.867 respectively. The smaller the insulator sheds spacing, the larger the proportion of air gap arc. And the lower the air pressure, the more serious the floating arc phenomenon. For every 1km increase in altitude, the average flashover voltages of FDZ and FS type roof insulators decrease by about 8.65% and 10.4%, respectively. The roof insulators with shed spacings of 30-35mm and shed combination of a large and two small are recommended at high altitudes.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3492-3501
Flashover Model of Insulator Based on Dynamic Variation of Pollution Layer Resistance—Part I
One of the primary threats to the reliable operation of power systems is the phenomenon of pollution flashover on insulators. Due to the intricate nature of the pollution flashover mechanism, existing flashover models face significant limitations in accurately analyzing the impact of critical factors such as environmental temperature, pollution layer wetting, and other variables on the resistance of the insulator’s pollution layer. This study aims to develop a dynamic pollution resistance model that accounts for the time-dependent variation of surface conductivity in polluted insulators. By incorporating the effects of leakage current evolution and moisture dynamics, the proposed model provides an improved predictive framework for pollution flashover under both AC and DC conditions. Experimental validation demonstrates that the model achieves high accuracy, with an average error of less than 5.2% compared to measured flashover voltages. The proposed model can be utilized to predict the flashover characteristics of contaminated insulators under both direct current (DC) and alternating current (AC) conditions.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3492-3501
Flashover Model of Insulator Based on Dynamic Variation of Pollution Layer Resistance—Part I
One of the primary threats to the reliable operation of power systems is the phenomenon of pollution flashover on insulators. Due to the intricate nature of the pollution flashover mechanism, existing flashover models face significant limitations in accurately analyzing the impact of critical factors such as environmental temperature, pollution layer wetting, and other variables on the resistance of the insulator’s pollution layer. This study aims to develop a dynamic pollution resistance model that accounts for the time-dependent variation of surface conductivity in polluted insulators. By incorporating the effects of leakage current evolution and moisture dynamics, the proposed model provides an improved predictive framework for pollution flashover under both AC and DC conditions. Experimental validation demonstrates that the model achieves high accuracy, with an average error of less than 5.2% compared to measured flashover voltages. The proposed model can be utilized to predict the flashover characteristics of contaminated insulators under both direct current (DC) and alternating current (AC) conditions.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3502-3510
Dynamic Prediction of Insulator Pollution Flashover and Analysis of Factors Influencing Pollution Flashover—Part II
Building on the pollution flashover model developed in Part I by Guo et al., this paper further explores the dynamic evolution of key parameters during the pollution flashover process, particularly we focus on the temporal variation and propagation characteristics of the arc. The analyzed parameters include leakage current, arc length, pollution layer resistance, as well as the temperature and thickness of the pollution layer. By examining the propagation speed and development trends of the arc, we provide deeper insights into the mechanisms governing insulator flashover under various environmental and operational conditions. Additionally, the effects of salt deposit density, ambient temperature, wetting layer thickness, and leakage current on the flashover characteristics of insulators are thoroughly examined. The relationships between arc initiation voltage, flashover probability, critical flashover arc length, and salt deposit density are analyzed, while accounting for the stochastic nature of discharge. Furthermore, the influence of ambient temperature, pollution layer wetness, and applied voltage on the pollution flashover characteristics is analyzed in detail, providing deeper insights into the mechanisms governing insulator flashover under various environmental and operational conditions.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3502-3510
Dynamic Prediction of Insulator Pollution Flashover and Analysis of Factors Influencing Pollution Flashover—Part II
Building on the pollution flashover model developed in Part I by Guo et al., this paper further explores the dynamic evolution of key parameters during the pollution flashover process, particularly we focus on the temporal variation and propagation characteristics of the arc. The analyzed parameters include leakage current, arc length, pollution layer resistance, as well as the temperature and thickness of the pollution layer. By examining the propagation speed and development trends of the arc, we provide deeper insights into the mechanisms governing insulator flashover under various environmental and operational conditions. Additionally, the effects of salt deposit density, ambient temperature, wetting layer thickness, and leakage current on the flashover characteristics of insulators are thoroughly examined. The relationships between arc initiation voltage, flashover probability, critical flashover arc length, and salt deposit density are analyzed, while accounting for the stochastic nature of discharge. Furthermore, the influence of ambient temperature, pollution layer wetness, and applied voltage on the pollution flashover characteristics is analyzed in detail, providing deeper insights into the mechanisms governing insulator flashover under various environmental and operational conditions.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Multicriteria Decision-Making Model for Assessing the Aging Condition of Composite Insulators Using AHP-Entroped TOPSIS
Current multi-dimensional parameter evaluation methods for assessing the aging condition of composite insulators face challenges such as subjective bias, objective absolutism, and data correlation interference, leading to unscientific weight allocation and inaccurate outcomes. To address these issues, this study proposes a multi-criteria decision-making (MCDM) model that combines the subjective weights of the analytic hierarchy process (AHP) with the objective weights of the entropy method. The model employs the technique for order preference by similarity to an ideal solution (TOPSIS) to calculate the distance between evaluation indicators and ideal positive/negative solutions, enabling precise quantitative evaluation of the aging condition. Accelerated aging experiments on three composite formulations were conducted, and twelve key quantitative indicators were extracted from samples at various aging stages. These indicators were used to develop the MCDM-TOPSIS evaluation model. Pearson correlation coefficients of -0.95, -0.93, and -0.94 between aging condition scores and aging time demonstrated a strong negative correlation. Sensitivity analysis showed a model error below 3%, highlighting its robustness. Compared to other models, the proposed approach achieved a 92% accuracy rate, confirming its effectiveness. This model provides theoretical insights and practical guidance for assessing the aging conditions of composite insulators.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Multicriteria Decision-Making Model for Assessing the Aging Condition of Composite Insulators Using AHP-Entroped TOPSIS
Current multi-dimensional parameter evaluation methods for assessing the aging condition of composite insulators face challenges such as subjective bias, objective absolutism, and data correlation interference, leading to unscientific weight allocation and inaccurate outcomes. To address these issues, this study proposes a multi-criteria decision-making (MCDM) model that combines the subjective weights of the analytic hierarchy process (AHP) with the objective weights of the entropy method. The model employs the technique for order preference by similarity to an ideal solution (TOPSIS) to calculate the distance between evaluation indicators and ideal positive/negative solutions, enabling precise quantitative evaluation of the aging condition. Accelerated aging experiments on three composite formulations were conducted, and twelve key quantitative indicators were extracted from samples at various aging stages. These indicators were used to develop the MCDM-TOPSIS evaluation model. Pearson correlation coefficients of -0.95, -0.93, and -0.94 between aging condition scores and aging time demonstrated a strong negative correlation. Sensitivity analysis showed a model error below 3%, highlighting its robustness. Compared to other models, the proposed approach achieved a 92% accuracy rate, confirming its effectiveness. This model provides theoretical insights and practical guidance for assessing the aging conditions of composite insulators.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 5084-5095
A Cooperative Optimization Method of Electric Field-Flow Field for Roof Insulators of High-Speed Trains
Aerodynamic drag generated during the high-speed train operation not only lowers operating efficiency and increases power consumption, but also restricts the speed for further improvement. As the existence of roof external insulation equipment, the aerodynamic drag on the roof increases and the optimization of drag reduction for it is an essential development trend. In this paper, a simulation model for the external insulation equipment is firstly established and validated. And a cooperative optimization method of electric field-flow field of roof insulator based on micro-macro bionic structure is proposed. Secondly, the datasets including eight input parameters and two output parameters are collected. Four surrogate models are constructed and compared to determine the preferable model. Then, the optimal structural parameters are obtained using the MOPSO algorithm. The flow field and electric field of roof insulator before and after optimization are analyzed. Finally, the 3D printed insulators are employed to verify its insulation performance. The results show that the optimized roof insulator can achieve 21.33% drag reduction. The average electric field strength decreases by 8.19%, and the flashover voltage is significantly improved. The cooperative improvement of aerodynamic drag reduction-insulation performance of the roof external insulation equipment is realized.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 5084-5095
A Cooperative Optimization Method of Electric Field-Flow Field for Roof Insulators of High-Speed Trains
Aerodynamic drag generated during the high-speed train operation not only lowers operating efficiency and increases power consumption, but also restricts the speed for further improvement. As the existence of roof external insulation equipment, the aerodynamic drag on the roof increases and the optimization of drag reduction for it is an essential development trend. In this paper, a simulation model for the external insulation equipment is firstly established and validated. And a cooperative optimization method of electric field-flow field of roof insulator based on micro-macro bionic structure is proposed. Secondly, the datasets including eight input parameters and two output parameters are collected. Four surrogate models are constructed and compared to determine the preferable model. Then, the optimal structural parameters are obtained using the MOPSO algorithm. The flow field and electric field of roof insulator before and after optimization are analyzed. Finally, the 3D printed insulators are employed to verify its insulation performance. The results show that the optimized roof insulator can achieve 21.33% drag reduction. The average electric field strength decreases by 8.19%, and the flashover voltage is significantly improved. The cooperative improvement of aerodynamic drag reduction-insulation performance of the roof external insulation equipment is realized.