Yuttapong Jiraraksopakun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuttapong Jiraraksopakun has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Apichai Bhatranand
Department of Electronics and Telecommunication Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
10 shared publications - Abdullahi Usman
Department of Electronics and Telecommunication Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
6 shared publications - Khalid Sabo Muhammad
Department of Electronic and Telecommunication Engineering, Faculty of Engineering, King Mongkuts University of Technology Thonburi, Bangkok, Thailand
3 shared publications - Chutchai Pawong
Physics Division, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok 10300, Thailand
2 shared publications - Prathan Buranasiri
King Mongkut's Institute of Technology Ladkrabang (Thailand)
2 shared publications - Rapeepan Kaewon
Department of Electrical Engineering, Faculty of Engineering and Industrial Technology, Silpakorn University, Nakhon Pathom 73000, Thailand
2 shared publications
Latest Publications
- Open Access
- 8 May 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (3) , 26
Efficient Visual Field Sensitivity Estimation via a Lightweight Global Context-Aware CNN Using Standard 2D OCT Thickness Maps
Glaucoma is a chronic progressive optic neuropathy causing irreversible blindness globally, underscoring the need for reliable diagnostic tools. While visual field (VF) testing remains the clinical standard, it has significant limitations, including subjective variability and patient cooperation difficulties. Optical coherence tomography (OCT) offers objective structural assessment. Recent deep learning approaches for VF prediction from OCT data can achieve high accuracy, but require raw three-dimensional volumetric data and substantial computational infrastructure that limit their deployment in routine clinical practice. We developed a lightweight convolutional neural network that predicts VF sensitivity from standard two-dimensional OCT thickness maps routinely available in clinical settings. The architecture integrates multiscale depthwise separable convolutions with attention mechanisms and employs an Exponentially Weighted Mean Squared Error loss function to enhance accuracy in clinically critical low-sensitivity regions. Using data from 241 subjects with five-fold cross-validation, our model achieved mean absolute error of 3.32 ± 2.35 dB and correlation of 0.74. This approach addresses the practical deployment limitations of existing methods while maintaining competitive accuracy, enabling implementation in resource-constrained clinical settings for patients who cannot reliably perform standard perimetry.
- 8 May 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (3) , 26
Open AccessEfficient Visual Field Sensitivity Estimation via a Lightweight Global Context-Aware CNN Using Standard 2D OCT Thickness Maps
Glaucoma is a chronic progressive optic neuropathy causing irreversible blindness globally, underscoring the need for reliable diagnostic tools. While visual field (VF) testing remains the clinical standard, it has significant limitations, including subjective variability and patient cooperation difficulties. Optical coherence tomography (OCT) offers objective structural assessment. Recent deep learning approaches for VF prediction from OCT data can achieve high accuracy, but require raw three-dimensional volumetric data and substantial computational infrastructure that limit their deployment in routine clinical practice. We developed a lightweight convolutional neural network that predicts VF sensitivity from standard two-dimensional OCT thickness maps routinely available in clinical settings. The architecture integrates multiscale depthwise separable convolutions with attention mechanisms and employs an Exponentially Weighted Mean Squared Error loss function to enhance accuracy in clinically critical low-sensitivity regions. Using data from 241 subjects with five-fold cross-validation, our model achieved mean absolute error of 3.32 ± 2.35 dB and correlation of 0.74. This approach addresses the practical deployment limitations of existing methods while maintaining competitive accuracy, enabling implementation in resource-constrained clinical settings for patients who cannot reliably perform standard perimetry.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 94764-94773
Efficient Distributed Fiber Intruder Detection and Localization-Based Upon Receiver Bandwidth Compression Model
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 94764-94773
Open AccessEfficient Distributed Fiber Intruder Detection and Localization-Based Upon Receiver Bandwidth Compression Model
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2868-2875
NiO thickness measurement using a rectangular-type Sagnac interferometer as the material transport layer in a perovskite solar cell
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2868-2875
NiO thickness measurement using a rectangular-type Sagnac interferometer as the material transport layer in a perovskite solar cell
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.
- 16 March 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (3) , 1-8
Comparative Studies of Circularly Polarized Light with Phase Shift in Sagnac and Mach-Zehnder Interferometers
- 16 March 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (3) , 1-8
Comparative Studies of Circularly Polarized Light with Phase Shift in Sagnac and Mach-Zehnder Interferometers
- 29 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (4) , 1135-1143
Phase-shifting determination and pattern recognition using a modified Sagnac interferometer with multiple reflections
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.
- 29 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (4) , 1135-1143
Phase-shifting determination and pattern recognition using a modified Sagnac interferometer with multiple reflections
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.
- 17 November 2022
- Published by IOP Publishing in Laser Physics
- Vol. 32 (12) , 125401
The comparison of multi-stepping algorithms for real-time thickness measurement of transparent thin films using polarization settings
This paper presents the comparison of three-, four- and five-step techniques for measuring transparent thin-film thickness of T a 2 O 5 and W O 3 deposited on BK-7 substrates. The Sagnac interferometer was modified with phase shifting approach for the determination of thin-film thickness. The input light beam was split into reference and testing beams. Before the output light reaching the balanced photodetectors, the real-time signal detection was performed to obtain the output intensities of both beams using three-, four-, and five-polarization settings of an analyzer. The thicknesses could then be efficiently translated from the measured intensities. Thicknesses from three-, four- and five-stepping algorithms were compared with ones from the conventional FE-SEM measurement, and it was discovered that the former performed better with less errors. The findings show that the phase-shifting technique using three-polarization settings is more suitable for the thickness measurement of the transparent thin film.
- 17 November 2022
- Published by IOP Publishing in Laser Physics
- Vol. 32 (12) , 125401
The comparison of multi-stepping algorithms for real-time thickness measurement of transparent thin films using polarization settings
This paper presents the comparison of three-, four- and five-step techniques for measuring transparent thin-film thickness of T a 2 O 5 and W O 3 deposited on BK-7 substrates. The Sagnac interferometer was modified with phase shifting approach for the determination of thin-film thickness. The input light beam was split into reference and testing beams. Before the output light reaching the balanced photodetectors, the real-time signal detection was performed to obtain the output intensities of both beams using three-, four-, and five-polarization settings of an analyzer. The thicknesses could then be efficiently translated from the measured intensities. Thicknesses from three-, four- and five-stepping algorithms were compared with ones from the conventional FE-SEM measurement, and it was discovered that the former performed better with less errors. The findings show that the phase-shifting technique using three-polarization settings is more suitable for the thickness measurement of the transparent thin film.
- Open Access
Real-Time Double-Layer Thin Film Thickness Measurements Using Modified Sagnac Interferometer with Polarization Phase Shifting Approach
This paper describes a modified Sagnac interferometer with a self-referenced polarization and phase-shifting technique for real-time thickness measurement of single- and double-layer transparent thin films. The proposed interferometric setup generated outstanding rotating linearly polarized light with a degree of polarization (DOP) of 99.40%. A beam splitter placed at the interferometer output separated the beam into two identical linearly polarized beams. One of the beams served as a reference, while the other served as a sensing arm. The output linear polarizer set at 45° relative to a reference plane was positioned anterior to the photodetectors to get rotating light intensities for phase shift measurement; hence, the intensities at various polarizations of 0°, 45°, and 90° were automatically acquired without any polarizing device adjustments. These intensities were then transformed into a phase retardation introduced by a sample, and the resulting phase shift was eventually converted into film thickness. The samples were properly prepared, with pure BK7 substrate being deposited by -, -, and / films of known thicknesses. The thickness measurement obtained from the proposed system yielded reading errors of 1.3%, 0.2%, and 1.3/2.5% for -, -, and / films, respectively. The mathematical theory was effectively demonstrated and empirically confirmed. The experimental results show that the proposed setup has a lot of potential for real-time, non-destructive thickness assessment of transparent thin films without the need to modify polarizing device orientations.Open AccessReal-Time Double-Layer Thin Film Thickness Measurements Using Modified Sagnac Interferometer with Polarization Phase Shifting Approach
This paper describes a modified Sagnac interferometer with a self-referenced polarization and phase-shifting technique for real-time thickness measurement of single- and double-layer transparent thin films. The proposed interferometric setup generated outstanding rotating linearly polarized light with a degree of polarization (DOP) of 99.40%. A beam splitter placed at the interferometer output separated the beam into two identical linearly polarized beams. One of the beams served as a reference, while the other served as a sensing arm. The output linear polarizer set at 45° relative to a reference plane was positioned anterior to the photodetectors to get rotating light intensities for phase shift measurement; hence, the intensities at various polarizations of 0°, 45°, and 90° were automatically acquired without any polarizing device adjustments. These intensities were then transformed into a phase retardation introduced by a sample, and the resulting phase shift was eventually converted into film thickness. The samples were properly prepared, with pure BK7 substrate being deposited by -, -, and / films of known thicknesses. The thickness measurement obtained from the proposed system yielded reading errors of 1.3%, 0.2%, and 1.3/2.5% for -, -, and / films, respectively. The mathematical theory was effectively demonstrated and empirically confirmed. The experimental results show that the proposed setup has a lot of potential for real-time, non-destructive thickness assessment of transparent thin films without the need to modify polarizing device orientations. - 28 September 2021
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 68 (21) , 1173-1180
Feasibility study of employing mechanically induced long-period fibre grating as optical-based sensors
The investigation of long-period fibre gratings formed by a 3D printer with several grating periods is presented here. The proposed grating device was pressed on to an optical fibre to observe the resonant wavelengths as a function of different groove periods. Results showed that devices with 700 and 800 nm grating period introduced resonant wavelengths of 1,487 and 1,570 nm with refractive index changes of 2.121 × 10−3 and 1.963 × 10−3, respectively. Once resonant wavelengths were known, an optical time domain reflectometer (OTDR) was employed to determine light behaviour, event positions, and losses. The OTDR trace revealed that the non-reflective event occurred at the grating perturbation position. Consequently, the wavelength-dependent-resonance was caused by the non-contra-directional coupling of light from the fibre core to fibre cladding and its attenuation was a cubic function of an applied force. The proposed approach, therefore, shows a great potential to be used for the sensing applications in the vulnerable environments.
- 28 September 2021
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 68 (21) , 1173-1180
Feasibility study of employing mechanically induced long-period fibre grating as optical-based sensors
The investigation of long-period fibre gratings formed by a 3D printer with several grating periods is presented here. The proposed grating device was pressed on to an optical fibre to observe the resonant wavelengths as a function of different groove periods. Results showed that devices with 700 and 800 nm grating period introduced resonant wavelengths of 1,487 and 1,570 nm with refractive index changes of 2.121 × 10−3 and 1.963 × 10−3, respectively. Once resonant wavelengths were known, an optical time domain reflectometer (OTDR) was employed to determine light behaviour, event positions, and losses. The OTDR trace revealed that the non-reflective event occurred at the grating perturbation position. Consequently, the wavelength-dependent-resonance was caused by the non-contra-directional coupling of light from the fibre core to fibre cladding and its attenuation was a cubic function of an applied force. The proposed approach, therefore, shows a great potential to be used for the sensing applications in the vulnerable environments.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 234-237
Design and Simulation of Thin Film Anti-Reflection Coating on Si-Based Photonic Devices
This paper presents anti-reflection coating designs and simulation on the Si-based photonic devices used in the optical communication. The simulations were performed to determine the reflectance spectrum of the single-layer and double-layer thin-film coatings. Several coating materials were chosen in simulation to obtain the best solution for light reflection reduction within the wavelengths of 1200-1600nm. The simulation results showed that the single-layer of SiO 2 thin- film yielded the reflectance value less than 7%, which was over 20% improvement from an uncoated sample. While, the double- layer anti-reflection coating of ZnSe/LiF showed the promising results of reflectivity less than 0.03% over the wavelengths of 1200-1600nm, which cover all the FTTx wavelength bands. Thus, the proposed ARC structure has the potential to be employed for light reflection reduction for Si-based photonic devices in optical communication networks and optical sensors.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 234-237
Design and Simulation of Thin Film Anti-Reflection Coating on Si-Based Photonic Devices
This paper presents anti-reflection coating designs and simulation on the Si-based photonic devices used in the optical communication. The simulations were performed to determine the reflectance spectrum of the single-layer and double-layer thin-film coatings. Several coating materials were chosen in simulation to obtain the best solution for light reflection reduction within the wavelengths of 1200-1600nm. The simulation results showed that the single-layer of SiO 2 thin- film yielded the reflectance value less than 7%, which was over 20% improvement from an uncoated sample. While, the double- layer anti-reflection coating of ZnSe/LiF showed the promising results of reflectivity less than 0.03% over the wavelengths of 1200-1600nm, which cover all the FTTx wavelength bands. Thus, the proposed ARC structure has the potential to be employed for light reflection reduction for Si-based photonic devices in optical communication networks and optical sensors.