Abdullahi Usman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdullahi Usman has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Apichai Bhatranand
Department of Electronics and Telecommunication Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
7 shared publications - Yuttapong Jiraraksopakun
Department of Electronics and Telecommunication Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
6 shared publications - Prathan Buranasiri
King Mongkut's Institute of Technology Ladkrabang (Thailand)
3 shared publications - Chutchai Pawong
Physics Division, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok 10300, Thailand
2 shared publications - Khalid Sabo Muhammad
Department of Electronic and Telecommunication Engineering, Faculty of Engineering, King Mongkuts University of Technology Thonburi, Bangkok, Thailand
2 shared publications - Rapeepan Kaewon
Department of Electrical Engineering, Faculty of Engineering and Industrial Technology, Silpakorn University, Nakhon Pathom 73000, Thailand
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by Elsevier in Next Materials
- Vol. 12
Modeling and experimental investigation of perovskite/black silicon/silicon tandem solar cells
- 1 May 2026
- Published by Elsevier in Next Materials
- Vol. 12
Open AccessModeling and experimental investigation of perovskite/black silicon/silicon tandem solar cells
- Open Access
- 9 October 2025
- Published by Elsevier in Next Materials
- Vol. 9
Computational study of nontoxic Cs2PtI₆ double perovskite as a lead-free photovoltaic absorber
- 9 October 2025
- Published by Elsevier in Next Materials
- Vol. 9
Open AccessComputational study of nontoxic Cs2PtI₆ double perovskite as a lead-free photovoltaic absorber
- Open Access
- 12 September 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (38) , 39663-39672
Modeling and Optimization of Modified TiO2 with Aluminum and Magnesium as ETL in MAPbI3 Perovskite Solar Cells: SCAPS 1D Frameworks
- 12 September 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (38) , 39663-39672
Open AccessModeling and Optimization of Modified TiO2 with Aluminum and Magnesium as ETL in MAPbI3 Perovskite Solar Cells: SCAPS 1D Frameworks
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2868-2875
NiO thickness measurement using a rectangular-type Sagnac interferometer as the material transport layer in a perovskite solar cell
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2868-2875
NiO thickness measurement using a rectangular-type Sagnac interferometer as the material transport layer in a perovskite solar cell
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.
- 16 March 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (3) , 1-8
Comparative Studies of Circularly Polarized Light with Phase Shift in Sagnac and Mach-Zehnder Interferometers
- 16 March 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (3) , 1-8
Comparative Studies of Circularly Polarized Light with Phase Shift in Sagnac and Mach-Zehnder Interferometers
- 29 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (4) , 1135-1143
Phase-shifting determination and pattern recognition using a modified Sagnac interferometer with multiple reflections
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.
- 29 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (4) , 1135-1143
Phase-shifting determination and pattern recognition using a modified Sagnac interferometer with multiple reflections
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.
- 4 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12672, 16-125
Polarization phase shifting for thickness measurement of NiO material transport layer using Sagnac interferometer
The optical interferometric technique with polarization phase shifting has been realized as one of the most important techniques for optical non-contact measurements. However, the measurement of thin film thickness using field emission scanning electron microscopy (FE-SEM) or scanning electron microscopy (SEM) has been inconvenient due to the high cost of maintenance. This research aims to measure the thickness of the Hole Transport Material Nickel (II) oxide (NiO) layer deposited on a glass substrate (NiO/FTO layer) using phase shifting in a Sagnac interferometer. In the experimental setup, the signal is split into the FTO reference arm and the NiO/FTO sample arm using a nonpolarizing beam splitter. The split signals are then detected through a balanced photodetector. By analyzing the signal intensities at polarization settings ranging from 0° to 90°, the phase shift and thickness of the NiO layer can be determined. In this study, a NiO thickness value of 281.64 nm was successfully achieved. To evaluate the accuracy of the proposed measurement method, the percentage error between the proposed technique and the conventional SEM method was computed. The percentage error was found to be 0.23%. These results indicate that the proposed setup holds promise as a cost-effective alternative to SEM for measuring thin film thickness.
- 4 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12672, 16-125
Polarization phase shifting for thickness measurement of NiO material transport layer using Sagnac interferometer
The optical interferometric technique with polarization phase shifting has been realized as one of the most important techniques for optical non-contact measurements. However, the measurement of thin film thickness using field emission scanning electron microscopy (FE-SEM) or scanning electron microscopy (SEM) has been inconvenient due to the high cost of maintenance. This research aims to measure the thickness of the Hole Transport Material Nickel (II) oxide (NiO) layer deposited on a glass substrate (NiO/FTO layer) using phase shifting in a Sagnac interferometer. In the experimental setup, the signal is split into the FTO reference arm and the NiO/FTO sample arm using a nonpolarizing beam splitter. The split signals are then detected through a balanced photodetector. By analyzing the signal intensities at polarization settings ranging from 0° to 90°, the phase shift and thickness of the NiO layer can be determined. In this study, a NiO thickness value of 281.64 nm was successfully achieved. To evaluate the accuracy of the proposed measurement method, the percentage error between the proposed technique and the conventional SEM method was computed. The percentage error was found to be 0.23%. These results indicate that the proposed setup holds promise as a cost-effective alternative to SEM for measuring thin film thickness.
- 17 November 2022
- Published by IOP Publishing in Laser Physics
- Vol. 32 (12) , 125401
The comparison of multi-stepping algorithms for real-time thickness measurement of transparent thin films using polarization settings
This paper presents the comparison of three-, four- and five-step techniques for measuring transparent thin-film thickness of T a 2 O 5 and W O 3 deposited on BK-7 substrates. The Sagnac interferometer was modified with phase shifting approach for the determination of thin-film thickness. The input light beam was split into reference and testing beams. Before the output light reaching the balanced photodetectors, the real-time signal detection was performed to obtain the output intensities of both beams using three-, four-, and five-polarization settings of an analyzer. The thicknesses could then be efficiently translated from the measured intensities. Thicknesses from three-, four- and five-stepping algorithms were compared with ones from the conventional FE-SEM measurement, and it was discovered that the former performed better with less errors. The findings show that the phase-shifting technique using three-polarization settings is more suitable for the thickness measurement of the transparent thin film.
- 17 November 2022
- Published by IOP Publishing in Laser Physics
- Vol. 32 (12) , 125401
The comparison of multi-stepping algorithms for real-time thickness measurement of transparent thin films using polarization settings
This paper presents the comparison of three-, four- and five-step techniques for measuring transparent thin-film thickness of T a 2 O 5 and W O 3 deposited on BK-7 substrates. The Sagnac interferometer was modified with phase shifting approach for the determination of thin-film thickness. The input light beam was split into reference and testing beams. Before the output light reaching the balanced photodetectors, the real-time signal detection was performed to obtain the output intensities of both beams using three-, four-, and five-polarization settings of an analyzer. The thicknesses could then be efficiently translated from the measured intensities. Thicknesses from three-, four- and five-stepping algorithms were compared with ones from the conventional FE-SEM measurement, and it was discovered that the former performed better with less errors. The findings show that the phase-shifting technique using three-polarization settings is more suitable for the thickness measurement of the transparent thin film.