Apichai Bhatranand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Apichai Bhatranand has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Yuttapong Jiraraksopakun
Department of Electronics and Telecommunication Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
10 shared publications - Abdullahi Usman
Department of Electronics and Telecommunication Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
7 shared publications - Chutchai Pawong
Physics Division, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok 10300, Thailand
3 shared publications - Khalid Sabo Muhammad
Department of Electronic and Telecommunication Engineering, Faculty of Engineering, King Mongkuts University of Technology Thonburi, Bangkok, Thailand
3 shared publications - Prathan Buranasiri
King Mongkut's Institute of Technology Ladkrabang (Thailand)
3 shared publications - Folad Fawad
Department of Electrical Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok, THAILAND
2 shared publications
Latest Publications
- Open Access
- 8 May 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (3) , 26
Efficient Visual Field Sensitivity Estimation via a Lightweight Global Context-Aware CNN Using Standard 2D OCT Thickness Maps
Glaucoma is a chronic progressive optic neuropathy causing irreversible blindness globally, underscoring the need for reliable diagnostic tools. While visual field (VF) testing remains the clinical standard, it has significant limitations, including subjective variability and patient cooperation difficulties. Optical coherence tomography (OCT) offers objective structural assessment. Recent deep learning approaches for VF prediction from OCT data can achieve high accuracy, but require raw three-dimensional volumetric data and substantial computational infrastructure that limit their deployment in routine clinical practice. We developed a lightweight convolutional neural network that predicts VF sensitivity from standard two-dimensional OCT thickness maps routinely available in clinical settings. The architecture integrates multiscale depthwise separable convolutions with attention mechanisms and employs an Exponentially Weighted Mean Squared Error loss function to enhance accuracy in clinically critical low-sensitivity regions. Using data from 241 subjects with five-fold cross-validation, our model achieved mean absolute error of 3.32 ± 2.35 dB and correlation of 0.74. This approach addresses the practical deployment limitations of existing methods while maintaining competitive accuracy, enabling implementation in resource-constrained clinical settings for patients who cannot reliably perform standard perimetry.
- 8 May 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (3) , 26
Open AccessEfficient Visual Field Sensitivity Estimation via a Lightweight Global Context-Aware CNN Using Standard 2D OCT Thickness Maps
Glaucoma is a chronic progressive optic neuropathy causing irreversible blindness globally, underscoring the need for reliable diagnostic tools. While visual field (VF) testing remains the clinical standard, it has significant limitations, including subjective variability and patient cooperation difficulties. Optical coherence tomography (OCT) offers objective structural assessment. Recent deep learning approaches for VF prediction from OCT data can achieve high accuracy, but require raw three-dimensional volumetric data and substantial computational infrastructure that limit their deployment in routine clinical practice. We developed a lightweight convolutional neural network that predicts VF sensitivity from standard two-dimensional OCT thickness maps routinely available in clinical settings. The architecture integrates multiscale depthwise separable convolutions with attention mechanisms and employs an Exponentially Weighted Mean Squared Error loss function to enhance accuracy in clinically critical low-sensitivity regions. Using data from 241 subjects with five-fold cross-validation, our model achieved mean absolute error of 3.32 ± 2.35 dB and correlation of 0.74. This approach addresses the practical deployment limitations of existing methods while maintaining competitive accuracy, enabling implementation in resource-constrained clinical settings for patients who cannot reliably perform standard perimetry.
- 16 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 154
Monitoring moisture and 2-furaldehyde concentration in transformer oil using a capacitive sensor
- 16 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 154
Monitoring moisture and 2-furaldehyde concentration in transformer oil using a capacitive sensor
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 94764-94773
Efficient Distributed Fiber Intruder Detection and Localization-Based Upon Receiver Bandwidth Compression Model
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 94764-94773
Open AccessEfficient Distributed Fiber Intruder Detection and Localization-Based Upon Receiver Bandwidth Compression Model
- Open Access
- 22 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 182846-182855
Monitoring Hydrogen and Methane Gases in Transformer Oil Using Palladium and Polydimethylsiloxane Coated Fiber Bragg Grating Sensors
This study presents Fiber Bragg Grating (FBG) sensors coated with palladium (Pd) and polydimethylsiloxane (PDMS) for detecting dissolved hydrogen (H₂) and methane (CH₄) in transformer oil, key indicators of incipient transformer faults. Laboratory evaluations covered concentrations of 5–2146 ppm for H₂ and 3–1551 ppm for CH₄ at 10–90°C. Gas-induced Bragg wavelength shifts were validated against Dissolved Gas Analysis (DGA) using the Transport X system. The Pd-coated H₂ sensors achieved sensitivities of 0.000487 nm/ppm with 97.04% accuracy and 0.000451 nm/ppm with 99.953% accuracy, while PDMS-coated CH₄ sensors reached 0.00591 nm/ppm with 95.85% accuracy and 0.00226 nm/ppm with 95.03% accuracy. All sensors exhibited strong linearity (R² > 0.91) and excellent repeatability (RSD < 1% above 40 °C). Temperature compensation models were developed to ensure accuracy under varying operational conditions. Compared with previously reported optical gas sensors, the proposed Pd- and PDMS-coated FBG sensors demonstrate superior sensitivity, broad detection range, thermal stability, and cost-effectiveness. These features make them highly promising for real-time, in-situ monitoring of dissolved gases, enabling advanced fault diagnosis and condition-based maintenance in power transformers.
- 22 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 182846-182855
Open AccessMonitoring Hydrogen and Methane Gases in Transformer Oil Using Palladium and Polydimethylsiloxane Coated Fiber Bragg Grating Sensors
This study presents Fiber Bragg Grating (FBG) sensors coated with palladium (Pd) and polydimethylsiloxane (PDMS) for detecting dissolved hydrogen (H₂) and methane (CH₄) in transformer oil, key indicators of incipient transformer faults. Laboratory evaluations covered concentrations of 5–2146 ppm for H₂ and 3–1551 ppm for CH₄ at 10–90°C. Gas-induced Bragg wavelength shifts were validated against Dissolved Gas Analysis (DGA) using the Transport X system. The Pd-coated H₂ sensors achieved sensitivities of 0.000487 nm/ppm with 97.04% accuracy and 0.000451 nm/ppm with 99.953% accuracy, while PDMS-coated CH₄ sensors reached 0.00591 nm/ppm with 95.85% accuracy and 0.00226 nm/ppm with 95.03% accuracy. All sensors exhibited strong linearity (R² > 0.91) and excellent repeatability (RSD < 1% above 40 °C). Temperature compensation models were developed to ensure accuracy under varying operational conditions. Compared with previously reported optical gas sensors, the proposed Pd- and PDMS-coated FBG sensors demonstrate superior sensitivity, broad detection range, thermal stability, and cost-effectiveness. These features make them highly promising for real-time, in-situ monitoring of dissolved gases, enabling advanced fault diagnosis and condition-based maintenance in power transformers.
- Open Access
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 113879-113889
Attention-Based Transfer Learning for Efficient Obstructive Sleep Apnea (OSA) Classification on Snore Sound
Polysomnography (PSG) is currently the gold-standard technique for classifying sleep apnea disorders. Yet, it is costly and requires an expert to score the severity, making it impractical for self-screening and home use. Snore sound classification with Deep Learning (DL) is a promising approach and has gained increasing interest due to its relationship with abnormal breathing conditions in both time and frequency domains. This study proposes an attention-based transfer learning model for non-invasive detection of obstructive sleep apnea (OSA) using audio signals. Mel-spectrograms and MFCC features were input into the MobileNetV3-Large to extract deep features. A modified SENet was implemented to provide suitable channel attention for the extracted features. The attention-based features are then classified into normal and abnormal snore events. The study evaluates model performance using 10-fold cross-validation on sound data of the 70 adult OSA patients of an open-source PSG-Audio dataset [1]. Results show that utilizing both Mel-Spectrogram and MFCCs as input features significantly enhances classification performance compared to single-feature models. In addition, the MobileNetV3-Large with modified SENet significantly outperforms the combination of other pre-trained and attention mechanisms. Specifically, the proposed model provides an accuracy of 92.576±0.910%, a sensitivity of 92.906±1.928%, a specificity of 92.269±2.740%, a precision of 92.173±3.024%, and an F1-score of 92.486±1.326% on the binary classification. Its performance also shows statistically significant improvement when benchmarked with other existing OSA classification models. Our proposed model demonstrates suitable potential for portable device-based sleep apnea monitoring applications.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 113879-113889
Open AccessAttention-Based Transfer Learning for Efficient Obstructive Sleep Apnea (OSA) Classification on Snore Sound
Polysomnography (PSG) is currently the gold-standard technique for classifying sleep apnea disorders. Yet, it is costly and requires an expert to score the severity, making it impractical for self-screening and home use. Snore sound classification with Deep Learning (DL) is a promising approach and has gained increasing interest due to its relationship with abnormal breathing conditions in both time and frequency domains. This study proposes an attention-based transfer learning model for non-invasive detection of obstructive sleep apnea (OSA) using audio signals. Mel-spectrograms and MFCC features were input into the MobileNetV3-Large to extract deep features. A modified SENet was implemented to provide suitable channel attention for the extracted features. The attention-based features are then classified into normal and abnormal snore events. The study evaluates model performance using 10-fold cross-validation on sound data of the 70 adult OSA patients of an open-source PSG-Audio dataset [1]. Results show that utilizing both Mel-Spectrogram and MFCCs as input features significantly enhances classification performance compared to single-feature models. In addition, the MobileNetV3-Large with modified SENet significantly outperforms the combination of other pre-trained and attention mechanisms. Specifically, the proposed model provides an accuracy of 92.576±0.910%, a sensitivity of 92.906±1.928%, a specificity of 92.269±2.740%, a precision of 92.173±3.024%, and an F1-score of 92.486±1.326% on the binary classification. Its performance also shows statistically significant improvement when benchmarked with other existing OSA classification models. Our proposed model demonstrates suitable potential for portable device-based sleep apnea monitoring applications.
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2868-2875
NiO thickness measurement using a rectangular-type Sagnac interferometer as the material transport layer in a perovskite solar cell
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2868-2875
NiO thickness measurement using a rectangular-type Sagnac interferometer as the material transport layer in a perovskite solar cell
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.
- 16 March 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (3) , 1-8
Comparative Studies of Circularly Polarized Light with Phase Shift in Sagnac and Mach-Zehnder Interferometers
- 16 March 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (3) , 1-8
Comparative Studies of Circularly Polarized Light with Phase Shift in Sagnac and Mach-Zehnder Interferometers
- 29 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (4) , 1135-1143
Phase-shifting determination and pattern recognition using a modified Sagnac interferometer with multiple reflections
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.
- 29 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (4) , 1135-1143
Phase-shifting determination and pattern recognition using a modified Sagnac interferometer with multiple reflections
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.