Siyoung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siyoung Lee has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Eunho Lee
Department of Chemical and Biomolecular Engineering Seoul National University of Science and Technology Seoul Republic of Korea
3 shared publications - Geun Yeol Bae
Green and Sustainable Materials R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea
3 shared publications - Eun Kwang Lee
Department of Chemical Engineering Pukyong National University Busan Republic of Korea
1 shared publication - Eun Young An
Green and Sustainable Materials R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea
1 shared publication - Geun Yeol Bae
Kumoh National Institute of Technology
1 shared publication - Gyojic Shin
Green Circulation R&D Department, Research Institute of Sustainable Development Technology, Korea Institute of Industrial Technology (KITECH), Cheonan-si, Republic of South Korea
1 shared publication
Latest Publications
- 27 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (4) , 673-682
Evaluation of Polymer Materials for MEMS Microphones
Polymers are attractive materials for the fabrication of micro-electro-mechanical system (MEMS) microphones because of their low Young’s moduli, generally lower processing temperatures than silicon, and simple fabrication; such microphones are sensitive and economical. However, an earlier polymer diaphragm revealed lower sensitivity than expected. In addition, the viscoelastic properties of polymer diaphragm have been considered to degrade the sensing performance due to a high-level mechanical noise. Here, we investigated the possibility of the polymer material as a MEMS microphone in terms of stiffness and damping. Stiffness was analyzed and experimentally verified. The obtained polymer diaphragm damping coefficient was compared with the coefficient of a silicon MEMS microphone to explore whether performance was degraded by material damping. All samples were fabricated using a thin film transfer method. SU-8 was mainly used but Polymethyl methacrylate (PMMA) was also selected for comparing the material damping effect. The measured residual stress of an SU-8 diaphragm was 18 MPa; the measured flexibility was similar to the state-of-art of a silicon-based MEMS microphone, and it was proven that there is room for further improvement through process optimization. The damping effect induced by viscoelasticity was very small, compared with the effect of air damping; indeed, the intrinsic damping effect of the polymer on device performance was negligible. [2021-0213]
- 27 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (4) , 673-682
Evaluation of Polymer Materials for MEMS Microphones
Polymers are attractive materials for the fabrication of micro-electro-mechanical system (MEMS) microphones because of their low Young’s moduli, generally lower processing temperatures than silicon, and simple fabrication; such microphones are sensitive and economical. However, an earlier polymer diaphragm revealed lower sensitivity than expected. In addition, the viscoelastic properties of polymer diaphragm have been considered to degrade the sensing performance due to a high-level mechanical noise. Here, we investigated the possibility of the polymer material as a MEMS microphone in terms of stiffness and damping. Stiffness was analyzed and experimentally verified. The obtained polymer diaphragm damping coefficient was compared with the coefficient of a silicon MEMS microphone to explore whether performance was degraded by material damping. All samples were fabricated using a thin film transfer method. SU-8 was mainly used but Polymethyl methacrylate (PMMA) was also selected for comparing the material damping effect. The measured residual stress of an SU-8 diaphragm was 18 MPa; the measured flexibility was similar to the state-of-art of a silicon-based MEMS microphone, and it was proven that there is room for further improvement through process optimization. The damping effect induced by viscoelasticity was very small, compared with the effect of air damping; indeed, the intrinsic damping effect of the polymer on device performance was negligible. [2021-0213]
- Open Access
- 27 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (11) , 2865
Self-Patterned Stretchable Electrode Based on Silver Nanowire Bundle Mesh Developed by Liquid Bridge Evaporation
A new strategy is required to realize a low-cost stretchable electrode while realizing high stretchability, conductivity, and manufacturability. In this study, we fabricated a self-patterned stretchable electrode using a simple and scalable process. The stretchable electrode is composed of a bridged square-shaped (BSS) AgNW bundle mesh developed by liquid bridge evaporation and a stretchable polymer matrix patterned with a microcavity array. Owing to the BSS structure and microcavity array, which effectively concentrate the applied strain on the deformable square region of the BSS structure under tensile stretching, the stretchable electrode exhibits high stretchability with a low ΔR/R0 of 10.3 at a strain of 40%. Furthermore, by exploiting the self-patterning ability—attributable to the difference in the ability to form liquid bridges according to the distance between microstructures—we successfully demonstrated a stretchable AgNW bundle mesh with complex patterns without using additional patterning processes. In particular, stretchable electrodes were fabricated by spray coating and bar coating, which are widely used in industry for low-cost mass production. We believe that this study significantly contributes to the commercialization of stretchable electronics while achieving high performance and complex patterns, such as stretchable displays and electronic skin.
- 27 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (11) , 2865
Open AccessSelf-Patterned Stretchable Electrode Based on Silver Nanowire Bundle Mesh Developed by Liquid Bridge Evaporation
A new strategy is required to realize a low-cost stretchable electrode while realizing high stretchability, conductivity, and manufacturability. In this study, we fabricated a self-patterned stretchable electrode using a simple and scalable process. The stretchable electrode is composed of a bridged square-shaped (BSS) AgNW bundle mesh developed by liquid bridge evaporation and a stretchable polymer matrix patterned with a microcavity array. Owing to the BSS structure and microcavity array, which effectively concentrate the applied strain on the deformable square region of the BSS structure under tensile stretching, the stretchable electrode exhibits high stretchability with a low ΔR/R0 of 10.3 at a strain of 40%. Furthermore, by exploiting the self-patterning ability—attributable to the difference in the ability to form liquid bridges according to the distance between microstructures—we successfully demonstrated a stretchable AgNW bundle mesh with complex patterns without using additional patterning processes. In particular, stretchable electrodes were fabricated by spray coating and bar coating, which are widely used in industry for low-cost mass production. We believe that this study significantly contributes to the commercialization of stretchable electronics while achieving high performance and complex patterns, such as stretchable displays and electronic skin.
- Open Access
- 22 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (11) , 2805
MoTe2 Field-Effect Transistors with Low Contact Resistance through Phase Tuning by Laser Irradiation
Due to their extraordinary electrical and physical properties, two-dimensional (2D) transition metal dichalcogenides (TMDs) are considered promising for use in next-generation electrical devices. However, the application of TMD-based devices is limited because of the Schottky barrier interface resulting from the absence of dangling bonds on the TMDs’ surface. Here, we introduce a facile phase-tuning approach for forming a homogenous interface between semiconducting hexagonal (2H) and semi-metallic monoclinic (1T′) molybdenum ditelluride (MoTe2). The formation of ohmic contacts increases the charge carrier mobility of MoTe2 field-effect transistor devices to 16.1 cm2 V−1s−1 with high reproducibility, while maintaining a high on/off current ratio by efficiently improving charge injection at the interface. The proposed method enables a simple fabrication process, local patterning, and large-area scaling for the creation of high-performance 2D electronic devices.
- 22 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (11) , 2805
Open AccessMoTe2 Field-Effect Transistors with Low Contact Resistance through Phase Tuning by Laser Irradiation
Due to their extraordinary electrical and physical properties, two-dimensional (2D) transition metal dichalcogenides (TMDs) are considered promising for use in next-generation electrical devices. However, the application of TMD-based devices is limited because of the Schottky barrier interface resulting from the absence of dangling bonds on the TMDs’ surface. Here, we introduce a facile phase-tuning approach for forming a homogenous interface between semiconducting hexagonal (2H) and semi-metallic monoclinic (1T′) molybdenum ditelluride (MoTe2). The formation of ohmic contacts increases the charge carrier mobility of MoTe2 field-effect transistor devices to 16.1 cm2 V−1s−1 with high reproducibility, while maintaining a high on/off current ratio by efficiently improving charge injection at the interface. The proposed method enables a simple fabrication process, local patterning, and large-area scaling for the creation of high-performance 2D electronic devices.
- Open Access
- 14 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1246
Transparent and Flexible Vibration Sensor Based on a Wheel-Shaped Hybrid Thin Membrane
With the advent of human–machine interaction and the Internet of Things, wearable and flexible vibration sensors have been developed to detect human voices and surrounding vibrations transmitted to humans. However, previous wearable vibration sensors have limitations in the sensing performance, such as frequency response, linearity of sensitivity, and esthetics. In this study, a transparent and flexible vibration sensor was developed by incorporating organic/inorganic hybrid materials into ultrathin membranes. The sensor exhibited a linear and high sensitivity (20 mV/g) and a flat frequency response (80–3000 Hz), which are attributed to the wheel-shaped capacitive diaphragm structure fabricated by exploiting the high processability and low stiffness of the organic material SU-8 and the high conductivity of the inorganic material ITO. The sensor also has sufficient esthetics as a wearable device because of the high transparency of SU-8 and ITO. In addition, the temperature of the post-annealing process after ITO sputtering was optimized for the high transparency and conductivity. The fabricated sensor showed significant potential for use in transparent healthcare devices to monitor the vibrations transmitted from hand-held vibration tools and in a skin-attachable vocal sensor.
- 14 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1246
Open AccessTransparent and Flexible Vibration Sensor Based on a Wheel-Shaped Hybrid Thin Membrane
With the advent of human–machine interaction and the Internet of Things, wearable and flexible vibration sensors have been developed to detect human voices and surrounding vibrations transmitted to humans. However, previous wearable vibration sensors have limitations in the sensing performance, such as frequency response, linearity of sensitivity, and esthetics. In this study, a transparent and flexible vibration sensor was developed by incorporating organic/inorganic hybrid materials into ultrathin membranes. The sensor exhibited a linear and high sensitivity (20 mV/g) and a flat frequency response (80–3000 Hz), which are attributed to the wheel-shaped capacitive diaphragm structure fabricated by exploiting the high processability and low stiffness of the organic material SU-8 and the high conductivity of the inorganic material ITO. The sensor also has sufficient esthetics as a wearable device because of the high transparency of SU-8 and ITO. In addition, the temperature of the post-annealing process after ITO sputtering was optimized for the high transparency and conductivity. The fabricated sensor showed significant potential for use in transparent healthcare devices to monitor the vibrations transmitted from hand-held vibration tools and in a skin-attachable vocal sensor.