Zhiqiang Yi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhiqiang Yi has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Weiheng Shao
Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou, China
8 shared publications - Xinxin Tian
School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou, China
4 shared publications - E. Shao
Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China, Shenzhen, China
2 shared publications - Hui Li
China Electronic Product Reliability and Environmental Testing Research Institute (CEPREI) Guangzhou Guangdong China
2 shared publications - Linyan Li
Institute of Technology, Sichuan Normal University, Chengdu, China
2 shared publications - Litao Ruan
Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou, China
2 shared publications
Latest Publications
- 20 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 25 (5) , 2245-2249
Analysis of Superposition Exceeding Radiation in Time-Domain Tightly Coupled Arrays
Time-domain antenna arrays are critical for transient applications, yet their radiation mechanisms remain insufficiently studied. Inspired bytightly coupled array (TCA), this work studies Vivaldi and transverse electromagnetic mode (TEM) horn antennas in a tightly coupled configuration. A novel phenomenon, called superposition exceeding radiation, is discovered, where the TD field synthesis efficiency (FSE) exceeds 100%. Theoretical analysis reveals that the tightly coupled structure functions as a transient current modulator, temporally redistributing energy toward the waveform peak. This is the primary contribution and innovation of this work. Measurements on a fourelement Vivaldi TCA show a FSE of 104.3%, with simulated and measured results in good agreement. This work clarifies the time-domain radiation mechanism of TCAs, thereby paving the way for extending their applications to transient electromagnetic systems.
- 20 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 25 (5) , 2245-2249
Analysis of Superposition Exceeding Radiation in Time-Domain Tightly Coupled Arrays
Time-domain antenna arrays are critical for transient applications, yet their radiation mechanisms remain insufficiently studied. Inspired bytightly coupled array (TCA), this work studies Vivaldi and transverse electromagnetic mode (TEM) horn antennas in a tightly coupled configuration. A novel phenomenon, called superposition exceeding radiation, is discovered, where the TD field synthesis efficiency (FSE) exceeds 100%. Theoretical analysis reveals that the tightly coupled structure functions as a transient current modulator, temporally redistributing energy toward the waveform peak. This is the primary contribution and innovation of this work. Measurements on a fourelement Vivaldi TCA show a FSE of 104.3%, with simulated and measured results in good agreement. This work clarifies the time-domain radiation mechanism of TCAs, thereby paving the way for extending their applications to transient electromagnetic systems.
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 729-735
An Active Tangential Electric Field Probe for Switching Noise Diagnosis in Power Modules
Wide-band-gap semiconductors have brought about a revolution in the speed of power electronic switching, but electromagnetic interference has become a new burden. In this paper, we present a tangential electric field probe dedicated to the diagnosis of power electron electromagnetic noise. The proposed probe adopts four-layer printed circuit board technology and can measure the Ex or Ey of the tangential electric field. The detection structure adopts enhanced dipole and differential amplifier with a 20 dB gain to improve the detection sensitivity. Through the measurement results, the proposed probe can operate from 100 kHz to 4.6 GHz, which is just right for power circuits. Its unwanted field suppression is above 10 dB, and maximum frequency response reach -25.8 dB at 0.65 GHz. The measurement results of a typical GaN power module demonstrate the effectiveness of the proposed probe.
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 729-735
An Active Tangential Electric Field Probe for Switching Noise Diagnosis in Power Modules
Wide-band-gap semiconductors have brought about a revolution in the speed of power electronic switching, but electromagnetic interference has become a new burden. In this paper, we present a tangential electric field probe dedicated to the diagnosis of power electron electromagnetic noise. The proposed probe adopts four-layer printed circuit board technology and can measure the Ex or Ey of the tangential electric field. The detection structure adopts enhanced dipole and differential amplifier with a 20 dB gain to improve the detection sensitivity. Through the measurement results, the proposed probe can operate from 100 kHz to 4.6 GHz, which is just right for power circuits. Its unwanted field suppression is above 10 dB, and maximum frequency response reach -25.8 dB at 0.65 GHz. The measurement results of a typical GaN power module demonstrate the effectiveness of the proposed probe.
- Open Access
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (1) , 100-109
Time-Domain Current Waveform Reconstruction of a Printed Trace via a Locally Enhanced Active H-Field Probing System
Time-domain current signal reconstruction is crucial for conducted electromagnetic interference measurements and signal diagnostics. Meanwhile, active magnetic field (H-field) probes significantly improve time-domain measurement sensitivity. This paper evaluates the effectiveness of the time-domain current waveform reconstruction technology on a printed trace via a locally enhanced active H-field probing system, and assesses algorithm accuracy and robustness by simulating the frequency response curves with different shapes. Comparative results demonstrate that the broadband reconstruction technology outperforms conventional integration methods in waveform fidelity when using the enhanced active H-field probe. The simulation results show that the broadband time-domain reconstruction technology can adapt to complex fluctuations in frequency response curve and provide relatively high-precision time-domain reconstruction results.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (1) , 100-109
Open AccessTime-Domain Current Waveform Reconstruction of a Printed Trace via a Locally Enhanced Active H-Field Probing System
Time-domain current signal reconstruction is crucial for conducted electromagnetic interference measurements and signal diagnostics. Meanwhile, active magnetic field (H-field) probes significantly improve time-domain measurement sensitivity. This paper evaluates the effectiveness of the time-domain current waveform reconstruction technology on a printed trace via a locally enhanced active H-field probing system, and assesses algorithm accuracy and robustness by simulating the frequency response curves with different shapes. Comparative results demonstrate that the broadband reconstruction technology outperforms conventional integration methods in waveform fidelity when using the enhanced active H-field probe. The simulation results show that the broadband time-domain reconstruction technology can adapt to complex fluctuations in frequency response curve and provide relatively high-precision time-domain reconstruction results.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 8026-8035
Design and Calibration of an Ungrounded Double-Loop Active Differential Magnetic Probe
In this paper, an ungrounded double-loop active differential magnetic field probe is proposed. The proposed probe includes two low noise amplifiers and an ungrounded double-loop detection structure, which can ensure a high magnetic field response. The detection structure also includes a shielded ground plate for suppressing electric field coupling and improving the common-mode rejection ratio (CMRR). Meanwhile, a rotate asymmetric calibration method (RACM) is used to correct the probing system’s asymmetry, improve the CMRR, and broaden the measurement frequency range. Therefore, the probing system combines several advanced design ideas, including adding two amplifiers, designing an ungrounded double-loop detection structure with shielded ground plate, using the asymmetric calibration method, and reserving differential output. The calibration data show that the proposed probe has a high magnetic field response factor of -19.8 dB at 2 GHz and a suppressed electric field response factor below -90 dB at 2 GHz. After using the RACM, a CMRR of more than 31.8 dB can be obtained when the frequency is less than 9 GHz. When the frequency is up to 14 GHz, the CMRR is better than 16 dB. The validation results of measuring three stand-wave points prove that the proposed probe and probing system can realize radio frequency magnetic field detection along a trace of up to 14 GHz.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 8026-8035
Design and Calibration of an Ungrounded Double-Loop Active Differential Magnetic Probe
In this paper, an ungrounded double-loop active differential magnetic field probe is proposed. The proposed probe includes two low noise amplifiers and an ungrounded double-loop detection structure, which can ensure a high magnetic field response. The detection structure also includes a shielded ground plate for suppressing electric field coupling and improving the common-mode rejection ratio (CMRR). Meanwhile, a rotate asymmetric calibration method (RACM) is used to correct the probing system’s asymmetry, improve the CMRR, and broaden the measurement frequency range. Therefore, the probing system combines several advanced design ideas, including adding two amplifiers, designing an ungrounded double-loop detection structure with shielded ground plate, using the asymmetric calibration method, and reserving differential output. The calibration data show that the proposed probe has a high magnetic field response factor of -19.8 dB at 2 GHz and a suppressed electric field response factor below -90 dB at 2 GHz. After using the RACM, a CMRR of more than 31.8 dB can be obtained when the frequency is less than 9 GHz. When the frequency is up to 14 GHz, the CMRR is better than 16 dB. The validation results of measuring three stand-wave points prove that the proposed probe and probing system can realize radio frequency magnetic field detection along a trace of up to 14 GHz.
- 27 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 71 (10) , 8366-8371
A Broadband Active Dual Probe by Asymmetric Calibration Method
The frequency response and sensitivity of a near-field probe can be improved by using a low noise amplifier (LNA). In this paper, a broadband active dual probe with two LNA is proposed as a high-performance near-field detection tool for the first time. For broadband passive dual probe, a strictly symmetric structure is required. However, the symmetry of the active dual probe is difficult to achieve due to many factors, such as redundant transmission structure and asymmetric LNA chip. Therefore, an asymmetric calibration method (ACM) is adopted to eliminate the effects of the asymmetric structure, which can broaden the operating frequency of the active dual probe. Besides, a characterization method of sensitivity for the active dual probe is presented with an independent source. By analyzing the relationship between the transfer matrix and the physical size (or time delay) of the asymmetric structure, the calibration results of the active probe by using the ACM have been verified. Meanwhile, the sensitivity of this active dual probe is also verified by comparing the calculation and measurement results. Further, by measuring a standing wave, the proposed active probe is broadened to 12 GHz by the ACM.
- 27 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 71 (10) , 8366-8371
A Broadband Active Dual Probe by Asymmetric Calibration Method
The frequency response and sensitivity of a near-field probe can be improved by using a low noise amplifier (LNA). In this paper, a broadband active dual probe with two LNA is proposed as a high-performance near-field detection tool for the first time. For broadband passive dual probe, a strictly symmetric structure is required. However, the symmetry of the active dual probe is difficult to achieve due to many factors, such as redundant transmission structure and asymmetric LNA chip. Therefore, an asymmetric calibration method (ACM) is adopted to eliminate the effects of the asymmetric structure, which can broaden the operating frequency of the active dual probe. Besides, a characterization method of sensitivity for the active dual probe is presented with an independent source. By analyzing the relationship between the transfer matrix and the physical size (or time delay) of the asymmetric structure, the calibration results of the active probe by using the ACM have been verified. Meanwhile, the sensitivity of this active dual probe is also verified by comparing the calculation and measurement results. Further, by measuring a standing wave, the proposed active probe is broadened to 12 GHz by the ACM.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (3) , 879-889
A Multicomponent Iterative Method for Efficient Source Reconstruction Based on Magnitude-Only and Single-Plane Near-Field Scanning
A multicomponent iterative method is proposed for efficient source reconstruction based on magnitude-only and single-plane near field scanning. Compared with the conventional method filling the multicomponent data into a whole transformation matrix, the multicomponent iterative method can save huge calculation time by evenly reducing the size of the transformation matrix into magnetic group and electric group, without losing solution accuracy of the equivalent dipole moments. The accuracy and efficiency of the proposed source reconstruction is verified on a simulated patch antenna model. The proposed method is also applied to efficiently find the equivalent sources and reconstruct the surface electromagnetic field of a practical serpentine line. For a larger transformation matrix (depending on the factors such as the scanned field components, scanned points, and dipole numbers), the proposed iteration method shows higher efficiency.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (3) , 879-889
A Multicomponent Iterative Method for Efficient Source Reconstruction Based on Magnitude-Only and Single-Plane Near-Field Scanning
A multicomponent iterative method is proposed for efficient source reconstruction based on magnitude-only and single-plane near field scanning. Compared with the conventional method filling the multicomponent data into a whole transformation matrix, the multicomponent iterative method can save huge calculation time by evenly reducing the size of the transformation matrix into magnetic group and electric group, without losing solution accuracy of the equivalent dipole moments. The accuracy and efficiency of the proposed source reconstruction is verified on a simulated patch antenna model. The proposed method is also applied to efficiently find the equivalent sources and reconstruct the surface electromagnetic field of a practical serpentine line. For a larger transformation matrix (depending on the factors such as the scanned field components, scanned points, and dipole numbers), the proposed iteration method shows higher efficiency.
- Open Access
- 20 September 2022
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 16 (13) , 831-840
Design and characterisation of a dual probe with double‐loop structure for simultaneous near‐field measurement
In this study, a near‐field dual probe with a double‐loop structure is designed and characterised. The high‐performance, low‐loss Rogers material and four‐layer printed circuit board are applied to design the double detection loop structure, which increases the detection area and effectively improves the frequency response of the probe. The key parameters of the probe, including the frequency response, calibration factor, sensitivity, spatial resolution, isolation and differential electric field suppression are characterised by a microstrip line. Compared with other dual probes, the proposed probe has better frequency response and higher sensitivity. The magnetic field sensitivity is −90.88 dB A/m/ and the electric field sensitivity is −46.89 dB A/m/ at 1 GHz.
- 20 September 2022
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 16 (13) , 831-840
Open AccessDesign and characterisation of a dual probe with double‐loop structure for simultaneous near‐field measurement
In this study, a near‐field dual probe with a double‐loop structure is designed and characterised. The high‐performance, low‐loss Rogers material and four‐layer printed circuit board are applied to design the double detection loop structure, which increases the detection area and effectively improves the frequency response of the probe. The key parameters of the probe, including the frequency response, calibration factor, sensitivity, spatial resolution, isolation and differential electric field suppression are characterised by a microstrip line. Compared with other dual probes, the proposed probe has better frequency response and higher sensitivity. The magnetic field sensitivity is −90.88 dB A/m/ and the electric field sensitivity is −46.89 dB A/m/ at 1 GHz.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (6) , 5723-5731
Design and Characterization of a Multi-Processed Differential Magnetic Field Probe by Using Asymmetric Calibration Method
In order to improve the spatial resolution of a magnetic near field probe, the design method combining multiple ports with multiple production processes has been proven effective. However, the asymmetry of transmission structure introduced by the junction between two different processes is a key problem that limits the performance of these probes. In this paper, a differential magnetic near field probe (diff-H-probe) combining flexible printed circuit (FPC) process with print circuit board (PCB) process has been manufactured to achieve high spatial resolution. The measurement results show that this probe can recognize a serpentine line with $100~\mu \text{m}$ -width of trace and $100~\mu \text{m}$ -space between traces. Meanwhile, an asymmetric calibration method (ACM) has been applied to significantly improve the performance of the diff-H-probe. Some key parameters of the probe with and without using the ACM are compared by using an air-dielectric microstrip line. The compared results show that the detection frequency range of the proposed probe is broaden to 12 GHz. Moreover, the results also demonstrate that the ACM can improve the differential electric field suppression up to 4.1 dB and improve the common mode electric field suppression to 20 dB at the frequency below 12 GHz.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (6) , 5723-5731
Design and Characterization of a Multi-Processed Differential Magnetic Field Probe by Using Asymmetric Calibration Method
In order to improve the spatial resolution of a magnetic near field probe, the design method combining multiple ports with multiple production processes has been proven effective. However, the asymmetry of transmission structure introduced by the junction between two different processes is a key problem that limits the performance of these probes. In this paper, a differential magnetic near field probe (diff-H-probe) combining flexible printed circuit (FPC) process with print circuit board (PCB) process has been manufactured to achieve high spatial resolution. The measurement results show that this probe can recognize a serpentine line with $100~\mu \text{m}$ -width of trace and $100~\mu \text{m}$ -space between traces. Meanwhile, an asymmetric calibration method (ACM) has been applied to significantly improve the performance of the diff-H-probe. Some key parameters of the probe with and without using the ACM are compared by using an air-dielectric microstrip line. The compared results show that the detection frequency range of the proposed probe is broaden to 12 GHz. Moreover, the results also demonstrate that the ACM can improve the differential electric field suppression up to 4.1 dB and improve the common mode electric field suppression to 20 dB at the frequency below 12 GHz.
- 18 October 2021
- Published by Wiley in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 32 (1) , e22944
A miniature shielded‐loop active H‐field probe design with high spatial resolution for near‐field measurement
- 18 October 2021
- Published by Wiley in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 32 (1) , e22944
A miniature shielded‐loop active H‐field probe design with high spatial resolution for near‐field measurement