MTMengqian Tian

Mengqian Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mengqian Tian has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a Passive Back-Support Exoskeleton Mimicking Human Spine Motion for Multi-Posture Assistance in Occupational Tasks

    by Jiyuan Wu, Zhiquan Chen, Yinglong Zhang, Qi Zhang, Xingsong Wang, Mengqian Tian

    Passive back-support exoskeletons commonly employ elastic components to assist users during dynamic tasks. However, these designs are ineffective in providing sustained assistance for prolonged static bending postures, such as those required in surgery, assembly, and farming, where users experience continuous lumbar flexion. To address this limitation, a novel passive back-support exoskeleton inspired by the human spine is proposed in this work. The exoskeleton integrates a five-bar linkage mechanism with vertebrae-mimicking units, allowing for both dynamic flexion–extension movements and rigid support at various flexion angles. During the experiments, subjects are instructed to perform a 30-min forward-bending assembly task under two conditions: with and without wearing the exoskeleton. Compared to the free condition, the electromyography results indicate a 10.1% reduction in integrated EMG (IEMG) and a 9.78% decrease in root mean square (RMS) values of the erector spinae with the exoskeleton. Meanwhile, the metabolic rate is decreased by 11.1%, highlighting the effectiveness of the exoskeleton in mitigating muscle fatigue during prolonged static work. This work provides a promising solution for reducing musculoskeletal strain in occupations requiring sustained forward bending, making it a valuable advancement in passive exoskeleton technology.


  • Open Access

    Biomimetic Design and Validation of an Adaptive Cable-Driven Elbow Exoskeleton Inspired by the Shrimp Shell

    by Mengqian Tian, Yishan Liu, Zhiquan Chen, Xingsong Wang, Qi Zhang, Bin Liu

    The application of exoskeleton robots has demonstrated promising effectiveness in promoting the recovery of motor skills in patients with upper limb dysfunction. However, the joint misalignment caused by rigid exoskeletons usually leads to an uncomfortable experience for users. In this work, an adaptive cable-driven elbow exoskeleton inspired by the structural characteristics of the shrimp shell was developed to facilitate the rehabilitation of the elbow joint and to provide more compliant human-exoskeleton interactions. The exoskeleton was specifically designed for elbow flexion and extension, with a total weight of approximately 0.6 kg. Based on the mechanical design and cable configuration of the exoskeleton, the kinematics and dynamics of driving cables were analyzed. Subsequently, a PID-based control strategy was designed with cable kinematics. To evaluate the practical performance of the proposed exoskeleton in elbow assistance, a prototype was established and experimented with six subjects. According to the experimental results, the measured elbow joint angle trajectory is generally consistent with the desired trajectory, with a mean position tracking accuracy of approximately 0.997, which supports motion stability in rehabilitation scenarios. Meanwhile, the collected sEMG values from biceps brachii and brachioradialis under the exoskeleton condition show a significant reduction in average muscle activation by 37.7% and 28.8%, respectively, compared to the condition without exoskeleton.


  • A Sensor-Less Guider Contact Force Estimation Approach for Endovascular Slender Robot-Assisted Guidance System

    by Renfei Zhang, Linjie Dong, Xingsong Wang, Mengqian Tian, Haobo Su

    Objective: The objective of this study is to propose and validate a contact force estimation method based on guider shape prediction, aiming at estimating the contact force between the distal end of the guider and the vascular wall. Methods: A guider prediction algorithm is developed to simulate the stable shape of different contact points within a phantom model. Subsequently, a shape-contact force model is established, and the contact force is estimated based on the parametric equation of the guider shape. A suspended force measuring platform is developed to validate the contact force estimation approach. Additionally, the influence of contact position and guider stiffness on contact force is analyzed. Results: The average accuracy of contact force estimation is 91.17%. The average relative error of the guider shape is 2.5%, with a maximum offset error of 4.6 mm. During the contact force estimation experiment, the maximum relative error of the contact force is 19.83%, and the force deviation is 1.6 × 10-2 N. For Nitinol 0.4 mm at contact point 1, the relative error of the contact force is 11.58%, with a force deviation of 3.0 × 10-3 N. Conclusion: The estimated contact force aligns well with the measured force, demonstrating the feasibility of the proposed contact force estimation method. Significance: This study establishes a sensor-less contact force estimation method for vascular interventional robot guidance systems, offering insights into improving the robot's ability to navigate narrow blood vessels. The analysis of contact force provides both theoretical and experimental foundations for the design and application of vascular interventional robot guidance systems.


  • Open Access

    Design and Control of a Cable-Driven Exoskeleton System for Upper-Extremity Rehabilitation

    by Zhiquan Chen, Jiyuan Wu, Chunqi Ju, Xingsong Wang, Mengqian Tian, Bin Liu

    Stroke rehabilitation with the assistance of exoskeleton robots has the potential to facilitate the recovery of motor skills by guiding, supporting, and encouraging movement in the affected limbs. In this work, an upper-extremity exoskeleton actuated by the cable transmission mechanism, was developed for rehabilitation training of stroke patients. The exoskeleton is designed with three DOFs, including shoulder abduction/adduction, shoulder flexion/extension, and elbow flexion/extension. The main body of exoskeleton is comprised of three links and two cuffs, with a total weight of approximately 1.7 kg. Based on the mechanical design and cable arrangement, the kinematics and dynamics of the actuation cables are analyzed. In addition, a PID-based position control strategy and an impedance control strategy are designed based on the cable kinematics and dynamics. To investigate the application performance in passive motion assistance, a prototype of the cable-driven exoskeleton system was established, and the corresponding experiments were conducted with five subjects. In position control experiments, the measured joint trajectories exhibit similar variation trends and close peek angles to the demonstration trajectory, which is the main emphasis in rehabilitation scenarios. Meanwhile, it can be inferred that the time lag is the primary reason for the tracking error between the expected and measured trajectories. As to the impedance control experiments, the statistical results indicate that the employment of lower impedance parameters tends to protect the human-robot interaction safety by sacrificing the tracking accuracy of joint position.


  • Open Access

    Tracked Inspection Robot: Teleoperation based on ROS and Unity 3D

    by Ruochen Du, Xingsong Wang, Mengqian Tian

    Deficiencies in depth and perspective perception often hinder teleoperation based on video observation, especially in monocular settings. The integration of virtual reality (VR) allows the operator to be more immersed in the working environment, which can optimize the operation process and reduce the difficulty of operation. Taking cable trench inspection as an application scenario, this paper proposed a teleoperation system based on robot operating system (ROS) and Unity. The proposed method achieved the synchronization of both virtual and real robot actions, enabling the transmission and visualization of multimodal sensor data, and eventually allowing operators to utilize the virtual interface for immersive robot operation. The results of the user survey verified the feasibility of using the tracked robot based on ROS to achieve teleoperation combined with VR, and the introduction of VR reduces the cognitive load.


  • Open Access

    Development of a Variable-Configuration Bionic Robotic Fish

    by Dan Xia, Yuyao Li, Zhihan Li, Mengqian Tian, Xingsong Wang

    Bionic robotic fish have advantages over traditional underwater propulsion. Most of the existing studies have been conducted with only one type of fish as a bionic object, but a single propulsion mode may not be able to achieve the different needs of underwater operations. In this paper, we designed a pneumatic variable-configuration soft bionic fish and completed the overall structure design. It was built with a cownose ray as the main-configuration bionic object and a Caranx melampygus as the secondary-configuration bionic object. The base structure, actuators, and variable-configuration modules of the robot were made using flexible materials. After completing the design of the structure and control system of the robot, the prototype was manufactured and an underwater test was completed. The tests results indicated that the robot fish could achieve underwater linear propulsion and turning movements in both configurations. The maximum propulsion speed of the main configuration was 38.24 mm/s and the turning angle speed was 5.6°/s, and the maximum propulsion speed of its secondary configuration was 43.05 mm/s and the turning angle speed was 30°/s. The feasibility of the machine fish structure and control scheme were verified.


  • Open Access

    Evaluation criteria and data analysis of interactive design of virtual reality training system for upper limb rehabilitation of stroke patients

    by Zixuan Xu, Xingsong Wang, Mengqian Tian

    With the development of virtual reality technology, its application in the field of medical rehabilitation has become more and more extensive, and it has gradually penetrated into the medical research on the rehabilitation of stroke patients. This paper proposes a set of evaluation criteria and rehabilitation data analysis methods for the interactive design of the upper limb rehabilitation virtual reality training system for stroke patients. Firstly, the characteristics and needs of upper limb rehabilitation of stroke patients are analyzed. Secondly, according to the characteristics of virtual reality technology, the evaluation criteria of interaction design are proposed. Finally, the method of training system rehabilitation data analysis is proposed based on hypothesis testing. The aim is to evaluate whether the interaction design of the virtual reality training system meets the rehabilitation needs of stroke patients, and to provide a useful reference for the analysis of the experimental results.