FZFateme Zare

Fateme Zare

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fateme Zare has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A High-Accuracy Deep Learning Framework for Fault Detection in Wound-Rotor Rotational Resolver

    by A. Jafari, F. Zare, Z. Zamani

    Resolvers are widely used in automotive, aerospace, and industrial systems where reliable position sensing is essential. Their durability ensures operation in environments where optical encoders and other sensors are prone to failure, but their susceptibility to electrical and mechanical faults can compromise safety, reliability, and performance. This study proposes an automated deep learning-based fault detection approach to identify and classify common faults such as eccentricity and short circuits in excitation or signal windings, which distort signals and impair position estimation. This is particularly important given the scarcity of methods that avoid manual feature engineering and perform fault classification automatically. Various fault scenarios were simulated to train a generalizable network, and several state-of-the-art architectures for temporal data classification were evaluated. While some models achieved acceptable performance, their micro F1 scores did not exceed 87%, motivating a hybrid architecture combining residual convolutional blocks, an LSTM layer, and an attention mechanism. The proposed model achieved a micro F1 score of 97% on unseen simulated scenarios and showed strong generalization in a laboratory experiment by correctly identifying the fault. These results confirm the effectiveness of the proposed hybrid architecture for accurate resolver fault detection and classification.


  • Open Access

    Novel Simplified Configuration for a Multi-Turn Variable Reluctance Resolver

    by Ali Zare, Fateme Zare, Farid Tootoonchian, Zahra Nasiri-Gheidari

  • Optimal Design of a Novel Multiturn Resolver Based on the Magnetic Equivalent Circuit Method

    by F. Zare, F. Tootoonchian

    Resolvers are among the most important position sensors for detecting rotational, linear, and 2-DoF motion. Multispeed resolvers offer high-accuracy position detection but cannot provide absolute position information. To overcome this limitation, multi-turn resolvers have been introduced, which not only maintain high accuracy but also enable absolute position detection. Conventional multi-turn resolvers consist of two separate resolvers housed within a common frame. In this paper, a novel configuration of a multi-turn resolver is proposed, which significantly simplifies the existing design. To address the high computational burden of Finite Element Analysis (FEA), the Magnetic Equivalent Circuit (MEC) method is employed to optimize both the number of rotor slots and the number of excitation winding turns. The performance index of the proposed configuration demonstrates not only structural simplicity but also high accuracy. A prototype of the proposed resolver is developed to validate the simulation results.


  • Optimization of Winding and Rotor Harmonics in Variable Reluctance Resolvers Using Bayesian Techniques

    by F. Zare, F. Tootoonchian

    Rotational resolvers are among the most important position sensors and are generally classified into two main categories: wound rotor and variable reluctance types. Although wound rotor resolvers offer higher accuracy, variable reluctance resolvers are widely favored due to their high reliability and simple manufacturing process. In this paper, a variable air-gap resolver is studied, and both the winding arrangement and rotor contour are optimized to enhance its accuracy to the level of, or even beyond, that of a wound rotor resolver. In this regard, various winding arrangements are analyzed including CECS (Concentrated Excitation and Concentrated Signal winding), CETS (Concentrated Excitation and Toroidal Signal), TECS (Toroidal Excitation and Concentrated Signal) and TETS (Toroidal Excitation and Toroidal Signal), and the one that yields the highest accuracy is selected. The impact of the number of rotor pole pairs on accuracy is also examined. Finally, harmonic components are introduced into the rotor contour to mitigate the harmonic content present in the signal voltages. The amplitude of the injected harmonics is optimized using Bayesian Optimization and Gaussian Process Regression (GPR), demonstrating that the resolver’s accuracy can reach -or even surpass- that of a wound rotor resolver. The optimization results are subsequently validated through prototyping.


  • Design, Simulation, and Fault Resilience Analysis of a Wound Rotor Resolver Based on a Novel Resilience Function

    by F. Zare

    Wound rotor resolvers are among the most critical position sensors, widely valued for their high accuracy, strong resistance to temperature variations, and extended operational lifespan. Recognizing the significant influence of winding configurations on resolver performance, this paper investigates the performance of rotational wound rotor resolvers with different excitation winding arrangements and compares their effectiveness. The results indicate that the proposed resolver with a toroidal excitation winding exhibits notably high accuracy. Furthermore, given that both electrical and mechanical faults can substantially impact resolver functionality, the performance of each design is analyzed under various electrical and mechanical fault conditions. To quantitatively evaluate the resolver’s fault tolerance, a novel resilience function based on the cumulative distribution function (CDF) is introduced, which estimates the probability that the position error index (AAPE) remains below a defined threshold under both healthy and various fault conditions. The simulation and theoretical results are finally validated through experimental testing on a fabricated prototype.


  • A New Resilient Configuration of Wound Rotor Resolver in Mechanical Fault Conditions

    by Fateme Zare, Farid Tootoonchian, Zahra Nasiri-Gheidari

    Resolvers are widely employed as position sensors to detect both rotational and linear displacement. Among the various types, wound rotor resolvers offer superior accuracy in absolute measurements, especially under mechanical fault conditions, but they present significant manufacturing challenges. This paper introduces a novel winding arrangement designed to simplify the manufacturing process of wound rotor resolvers and enhance the accuracy of the sensor under mechanical fault conditions. The performance of the resolver with this new winding configuration is analyzed, with a particular focus on its resilience to eccentricity faults. To validate the high fault tolerance of the proposed design, a prototype of the optimized configuration was developed and tested. The performance of the prototype under these conditions was comprehensively evaluated through experimental measurements.


  • A Tubular Variable Reluctance Resolver With Single Coil Excitation Winding

    by F. Tootoonchian, F. Zare

    Transverse edge effect and longitudinal end effect are common reasons for reducing the accuracy of linear position sensors. Using tubular configuration leads to remove the first effect. However, that solution increases the destructive effect of the longitudinal end effect. In this paper a new configuration is proposed for the tubular Variable Reluctance (VR) resolver to suppress both longitudinal and transvers edge effects, simultaneously. In the proposed configuration a single coil is used as the excitation winding and constant-turn, non-overlapping coils are employed as signal windings. The influence of pole pitch value and the outer/inner stator configurations are discussed using 3-D time stepping finite element analysis. Finally, the prototype of the best configuration is built and the measured results approve the success of the developed sensor.


  • Sinusoidal Area 2-DoF Variable Reluctance Resolver

    by F. Tootoonchian, F. Zare

    Two-Degree of Freedom (2-DoF) electrical machines invention, leads to simultaneous produce motion in more than one direction with a single electrical machine. In order to drive such machines, employing position sensors in each direction is necessary. Using a 2-DoF position sensor instead of two separate ones, reduce the control system complexity and the sensor’s mass and volume. In this paper, a sinusoidal area 2-DoF variable reluctance resolver for detecting position in rotational and/or linear motion is proposed for the first time. The performance of the sensor for rotational, linear, and helical motions is evaluated using 3-D time transient finite element analysis. The optimal configuration of the sensor with minimized position error and the smallest size is considered for prototyping. The measured results verified the distinguished performance of the developed sensor.


  • Open Access

    Magnetic Equivalent Circuit Model for Performance Prediction of Two-DOF Planar Resolver

    by Fateme Zare, Farid Tootoonchian, Ahmad Daniar, Matthew C. Gardner, Bilal Akin

    In this paper, an analytical model based on the Magnetic Equivalent Circuit (MEC) method is developed for a planar wound mover two-degree of freedom (2-DOF) resolver. Planar resolvers enable mass, volume, and complexity reductions for position control of 2-DOF linear actuators. However, similar to any other linear electromagnetic sensors, the performance of the planar resolvers is negatively affected by the limited dimensions of the mover’s ferromagnetic core. Thus, it is necessary to develop an appropriate compensation method. On the other hand, the 3-D geometry of the sensor necessitates extremely time consuming 3-D time-stepping analysis. Therefore, a fast yet accurate analytical model is critical for the iterative design and compensation algorithm. In order to address these modeling limitations, the slot-tooth region and longitudinal end effect are included in the model. Then, its accuracy is verified by comparing the results with those of the 3-D time stepping finite element method (TSFEM). Then, the developed model is employed for design optimization to compensate for the end effects. Finally, the optimal sensor is experimentally prototyped and tested.