Georgios Kalantzis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Georgios Kalantzis has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bin Han
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA
1 shared publication Gary Luxton
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California, USA
1 shared publication- Guillem Pratx
Stanford University
1 shared publication Jianguo Qian
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California, USA
1 shared publicationLuis A. Vasquez-Quino
Radiation Oncology Department, University of Texas, Health Science Center San Antonio, Texas 78229
1 shared publicationTravis Zalman
Radiation Oncology Department, University of Texas, Health Science Center San Antonio, Texas 78229
1 shared publication
Latest Publications
- Open Access
- 1 January 2012
- Published by Medknow in Journal of Medical Physics
- Vol. 37 (4) , 193-9
Fidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams
The purpose of this study is to assess fidelity of radiation delivery between high and low dose rates of the flattening filter free (FFF) modes of a new all-digital design medical linear accelerator (Varian TrueBeam TM ), particularly for plans optimized for volumetric modulated arc therapy (VMAT). Measurements were made for the two energies of flattening filter free photon beams with a Varian TrueBeam TM linac: 6 MV (6 XFFF) at 400 and 1400 MU/min, and 10 MV (10 XFFF) at 400 and 2400 MU/ min. Data acquisition and analysis was performed with both ionization chambers and diode detector system Delta 4 , for square radiation fields and for 8 VMAT treatment plans optimized for SBRT treatment of lung tumors. For the square fields, a percent dose difference between high and low dose rate of the order of 0.3-0.4% for both photon energies was seen with the ionization chambers, while the contribution to the difference from ion recombination was found to be negligible. For both the VMAT and square-field deliveries, the Delta 4 showed the same average percent dose difference between the two dose rates of ~0.8% and ~0.6% for 10 MV and 6 MV, respectively, with the lower dose rate values giving the greater measured dose compared to the high dose rate. Thus, the VMAT deliveries introduced negligible dose differences between high and low dose rate. Finally, reproducibility of dose measurements was good for both energies.
- 1 January 2012
- Published by Medknow in Journal of Medical Physics
- Vol. 37 (4) , 193-9
Open AccessFidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams
The purpose of this study is to assess fidelity of radiation delivery between high and low dose rates of the flattening filter free (FFF) modes of a new all-digital design medical linear accelerator (Varian TrueBeam TM ), particularly for plans optimized for volumetric modulated arc therapy (VMAT). Measurements were made for the two energies of flattening filter free photon beams with a Varian TrueBeam TM linac: 6 MV (6 XFFF) at 400 and 1400 MU/min, and 10 MV (10 XFFF) at 400 and 2400 MU/ min. Data acquisition and analysis was performed with both ionization chambers and diode detector system Delta 4 , for square radiation fields and for 8 VMAT treatment plans optimized for SBRT treatment of lung tumors. For the square fields, a percent dose difference between high and low dose rate of the order of 0.3-0.4% for both photon energies was seen with the ionization chambers, while the contribution to the difference from ion recombination was found to be negligible. For both the VMAT and square-field deliveries, the Delta 4 showed the same average percent dose difference between the two dose rates of ~0.8% and ~0.6% for 10 MV and 6 MV, respectively, with the lower dose rate values giving the greater measured dose compared to the high dose rate. Thus, the VMAT deliveries introduced negligible dose differences between high and low dose rate. Finally, reproducibility of dose measurements was good for both energies.
- 27 September 2011
- Published by Wiley in Medical Physics
- Vol. 38 (10) , 5807-5817
Toward IMRT 2D dose modeling using artificial neural networks: A feasibility study
Purpose: To investigate the feasibility of artificial neural networks (ANN) to reconstruct dose maps for intensity modulated radiation treatment (IMRT) fields compared with those of the treatment planning system (TPS). Methods: An artificial feed forward neural network and the back‐propagation learning algorithm have been used to replicate dose calculations of IMRT fields obtained fromPINNACLE3 v9.0. The ANN was trained with fluence and dose maps of IMRT fields for 6 MV x‐rays, which were obtained from the amorphous silicon (a‐Si) electronic portal imaging device of Novalis TX. Those fluence distributions were imported to the TPS and the dose maps were calculated on the horizontal midpoint plane of a water equivalent homogeneous cylindrical virtual phantom. Each exported 2D dose distribution from the TPS was classified into two clusters of high and low dose regions, respectively, based on the K‐means algorithm and the Euclidian metric in the fluence‐dose domain. The data of each cluster were divided into two sets for the training and validation phase of the ANN, respectively. After the completion of the ANN training phase, 2D dose maps were reconstructed by the ANN and isodose distributions were created. The dose maps reconstructed by ANN were evaluated and compared with the TPS, where the mean absolute deviation of the dose and the γ‐index were used. Results: A good agreement between the doses calculated from the TPS and the trained ANN was achieved. In particular, an average relative dosimetric difference of 4.6% and an average γ‐index passing rate of 93% were obtained for low dose regions, and a dosimetric difference of 2.3% and an average γ‐index passing rate of 97% for high dose region. Conclusions: An artificial neural network has been developed to convert fluence maps to corresponding dose maps. The feasibility and potential of an artificial neural network to replicate complex convolution kernels in the TPS for IMRT dose calculations have been demonstrated.
- 27 September 2011
- Published by Wiley in Medical Physics
- Vol. 38 (10) , 5807-5817
Toward IMRT 2D dose modeling using artificial neural networks: A feasibility study
Purpose: To investigate the feasibility of artificial neural networks (ANN) to reconstruct dose maps for intensity modulated radiation treatment (IMRT) fields compared with those of the treatment planning system (TPS). Methods: An artificial feed forward neural network and the back‐propagation learning algorithm have been used to replicate dose calculations of IMRT fields obtained fromPINNACLE3 v9.0. The ANN was trained with fluence and dose maps of IMRT fields for 6 MV x‐rays, which were obtained from the amorphous silicon (a‐Si) electronic portal imaging device of Novalis TX. Those fluence distributions were imported to the TPS and the dose maps were calculated on the horizontal midpoint plane of a water equivalent homogeneous cylindrical virtual phantom. Each exported 2D dose distribution from the TPS was classified into two clusters of high and low dose regions, respectively, based on the K‐means algorithm and the Euclidian metric in the fluence‐dose domain. The data of each cluster were divided into two sets for the training and validation phase of the ANN, respectively. After the completion of the ANN training phase, 2D dose maps were reconstructed by the ANN and isodose distributions were created. The dose maps reconstructed by ANN were evaluated and compared with the TPS, where the mean absolute deviation of the dose and the γ‐index were used. Results: A good agreement between the doses calculated from the TPS and the trained ANN was achieved. In particular, an average relative dosimetric difference of 4.6% and an average γ‐index passing rate of 93% were obtained for low dose regions, and a dosimetric difference of 2.3% and an average γ‐index passing rate of 97% for high dose region. Conclusions: An artificial neural network has been developed to convert fluence maps to corresponding dose maps. The feasibility and potential of an artificial neural network to replicate complex convolution kernels in the TPS for IMRT dose calculations have been demonstrated.