Qisong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qisong Liu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Gang Xiong
Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China
1 shared publication - Guihong Lan
College of Chemistry and Chemical Engineering, Southwest Petroleum University, Chengdu, China
1 shared publication - Honggang Chang
Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China
1 shared publication - Jinjin Li
Research Institute of Natural Gas Technology, PetroChina Southwest Oil&Gasfield Company, Chengdu, China
1 shared publication - Jinlong He
Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China
1 shared publication - Ke Liu
Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China
1 shared publication
Latest Publications
- Open Access
Genomic Insights and Biodesulfurization Application of an Efficient Desulfurizer Strain TYWJ-2
Hydrogen sulfide (H2S) prevalent in fuel gases such as natural gas and biogas necessitates removal prior to utilization or pipeline distribution. Biological desulfurization is considered a green purification technology employing sulfur-oxidizing bacteria (SOB) under ambient conditions to eliminate sulfur compounds, offering advantages including high efficiency, simplified equipment, and minimal chemical consumption. A highly efficient SOB TYWJ-2 was isolated in this study. Genomic analysis revealed that strain TYWJ-2 possesses a complete set of sulfur metabolism genes, enabling the metabolism of various inorganic sulfides, along with salt-tolerance genes that support adaptation to high osmolarity environments. The optimal conditions for desulfurization were determined through single-factor experiments and Box–Behnken response surface methodology. Long-term desulfurization performance demonstrated stable operational efficiency, with H2S removal rates consistently reaching 99.72~99.87%. System performance remained robust under varying sulfur loads, elevated salinity, and intermittent operational shutdowns, with no significant decline in desulfurization efficiency observed. These findings indicate that strain TYWJ-2 holds considerable potential for the biological desulfurization of sulfur-containing biogas and natural gas.
Open AccessGenomic Insights and Biodesulfurization Application of an Efficient Desulfurizer Strain TYWJ-2
Hydrogen sulfide (H2S) prevalent in fuel gases such as natural gas and biogas necessitates removal prior to utilization or pipeline distribution. Biological desulfurization is considered a green purification technology employing sulfur-oxidizing bacteria (SOB) under ambient conditions to eliminate sulfur compounds, offering advantages including high efficiency, simplified equipment, and minimal chemical consumption. A highly efficient SOB TYWJ-2 was isolated in this study. Genomic analysis revealed that strain TYWJ-2 possesses a complete set of sulfur metabolism genes, enabling the metabolism of various inorganic sulfides, along with salt-tolerance genes that support adaptation to high osmolarity environments. The optimal conditions for desulfurization were determined through single-factor experiments and Box–Behnken response surface methodology. Long-term desulfurization performance demonstrated stable operational efficiency, with H2S removal rates consistently reaching 99.72~99.87%. System performance remained robust under varying sulfur loads, elevated salinity, and intermittent operational shutdowns, with no significant decline in desulfurization efficiency observed. These findings indicate that strain TYWJ-2 holds considerable potential for the biological desulfurization of sulfur-containing biogas and natural gas.
- Open Access
CFD Research on Natural Gas Sampling in a Horizontal Pipeline
Accurately determining if the sample parameters from a natural gas pipeline’s sampling system reflect the fluid characteristics of the main pipe has been a significant industry concern for many years. In this paper, samples of natural gas in a horizontal pipeline are investigated. CFD is used in this work and the turbulence is considered in the simulation. Firstly, the critical diameter for particles affected by gravity within such pipeline is determined. And then, the effects of the operation pressure and velocity of sampling branches on sample parameters, and the influence of particle density on these sample parameters, are analyzed. Finally, four different structures of sample branches for natural gas in a horizontal pipeline are compared. It is found that 100 μm is the critical diameter at which particles are affected by gravity; the operating pressure of the sampling branch has a significant impact on the particle mass concentration. The particle density has little impact on the sampling system. Overall, the design of the sampling branches does not cause significant sampling errors. This study provides guidance for optimal sampling in existing natural gas pipelines and enables effective monitoring of particle impurity content and properties in natural gas.
Open AccessCFD Research on Natural Gas Sampling in a Horizontal Pipeline
Accurately determining if the sample parameters from a natural gas pipeline’s sampling system reflect the fluid characteristics of the main pipe has been a significant industry concern for many years. In this paper, samples of natural gas in a horizontal pipeline are investigated. CFD is used in this work and the turbulence is considered in the simulation. Firstly, the critical diameter for particles affected by gravity within such pipeline is determined. And then, the effects of the operation pressure and velocity of sampling branches on sample parameters, and the influence of particle density on these sample parameters, are analyzed. Finally, four different structures of sample branches for natural gas in a horizontal pipeline are compared. It is found that 100 μm is the critical diameter at which particles are affected by gravity; the operating pressure of the sampling branch has a significant impact on the particle mass concentration. The particle density has little impact on the sampling system. Overall, the design of the sampling branches does not cause significant sampling errors. This study provides guidance for optimal sampling in existing natural gas pipelines and enables effective monitoring of particle impurity content and properties in natural gas.
- Open Access
Modeling CO2, H2S, COS, and CH3SH Simultaneous Removal Using Aqueous Sulfolane–MDEA Solution
In this study, a rate-based absorption model coupled with an improved thermodynamic model was developed to characterize the removal of acid components (CO2 and H2S) and organic sulfur (COS and CH3SH) from natural gas with an aqueous sulfolane–MDEA solution. First, the accuracy of the thermodynamic model was validated by comparing the calculated partial pressure of CO2, H2S, and CH3SH with those of the experimental data reported in the literature. Then, the industrial test data were employed to validate the absorption model and the simulation results agreed well with the experimental data. The average relative errors of the removal rates of CO2, COS, and CH3SH are 3.3%, 3.0%, 4.1%, respectively. Based on the validated coupled model, the total mass transfer coefficient and mass transfer resistance of each solute component at different column positions were analyzed. The effects of the gas–liquid ratio, overflow weir height, and absorption pressure on the absorption performance of each component were studied, and the influence of the acid component concentration in the feed gas on the removal efficiency of methyl mercaptan (CH3SH) was also discussed. It is found that the improved absorption model can better characterize the absorption performance and be conducive to the optimal design of the absorber column.
Open AccessModeling CO2, H2S, COS, and CH3SH Simultaneous Removal Using Aqueous Sulfolane–MDEA Solution
In this study, a rate-based absorption model coupled with an improved thermodynamic model was developed to characterize the removal of acid components (CO2 and H2S) and organic sulfur (COS and CH3SH) from natural gas with an aqueous sulfolane–MDEA solution. First, the accuracy of the thermodynamic model was validated by comparing the calculated partial pressure of CO2, H2S, and CH3SH with those of the experimental data reported in the literature. Then, the industrial test data were employed to validate the absorption model and the simulation results agreed well with the experimental data. The average relative errors of the removal rates of CO2, COS, and CH3SH are 3.3%, 3.0%, 4.1%, respectively. Based on the validated coupled model, the total mass transfer coefficient and mass transfer resistance of each solute component at different column positions were analyzed. The effects of the gas–liquid ratio, overflow weir height, and absorption pressure on the absorption performance of each component were studied, and the influence of the acid component concentration in the feed gas on the removal efficiency of methyl mercaptan (CH3SH) was also discussed. It is found that the improved absorption model can better characterize the absorption performance and be conducive to the optimal design of the absorber column.