Fedor S. Rusanov
Research Subjects
Fedor S. Rusanov has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Irina Ya. Poyurovskaya
Central Research Institute of Dentistry and Maxillofacial Surgery
6 shared publications - Fedor F. Losev
Central research Institute of dentistry and maxillofacial surgery Ministry of health of Russia
5 shared publications - Tat'Yana Vladislavovna Brailovskaya
National Medical Research Centre for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia; Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation
4 shared publications - A.F. Sharganov
National Medical Research Center for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia
2 shared publications - Alexander Khasan
Peoples’ Friendship University of Russia” (RUDN University), Medical Institute
2 shared publications - Larisa Petrovna Kiselnikova
Federal State Budgetary Educational Institution of Higher Education “Russian University of Medicine” of the Ministry of Health of the Russian Federation;Moscow Healthcare Departmen
2 shared publications
Latest Publications
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 13-18
Comparative analysis of microhardness of polymeric materials for temporary restorations manufactured using different technologies
Objective. Comparative study of the surface hardness of polymer materials for temporary crowns, differing in composition and manufacturing technology, in a dry state and after exposure to an aqueous medium. Material and methods. 4 materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot curing), Tempocor (cold curing). The disc-shaped samples were polished and kept in dry conditions or distilled water (37 °C, 7 days). The Vickers hardness was measured on a Duramin-20 microhardness tester (load 25 g, exposure 15 s). Statistical processing is the Student’s t-test. Results. In the dry state, all materials showed similar hardness (19—22 HV). The smallest decrease in hardness after water was observed in Huge PMMA (<7%) and Sinma-M (~3%). Dental Sand Pro showed a decrease of 12.4%. The maximum drop was in Tempocor (by 17%: from 19.72 to 16.37 HV). Microstructurally, Dental Sand Pro and Tempocor have pores and inhomogeneities. Conclusion. It is most stable in the aquatic environment of Huge PMMA (CAD/CAM). Sinma-M (hot polymerization) also demonstrates high stability. Dental Sand Pro 3D printing material requires optimization of post-polymerization modes. Tempocor (cold curing) is the least water-resistant, and its use for long-term temporary restoration is limited. Surface hardness is an informative criterion for preclinical assessment of the reliability of temporary restorations.
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 13-18
Comparative analysis of microhardness of polymeric materials for temporary restorations manufactured using different technologies
Objective. Comparative study of the surface hardness of polymer materials for temporary crowns, differing in composition and manufacturing technology, in a dry state and after exposure to an aqueous medium. Material and methods. 4 materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot curing), Tempocor (cold curing). The disc-shaped samples were polished and kept in dry conditions or distilled water (37 °C, 7 days). The Vickers hardness was measured on a Duramin-20 microhardness tester (load 25 g, exposure 15 s). Statistical processing is the Student’s t-test. Results. In the dry state, all materials showed similar hardness (19—22 HV). The smallest decrease in hardness after water was observed in Huge PMMA (<7%) and Sinma-M (~3%). Dental Sand Pro showed a decrease of 12.4%. The maximum drop was in Tempocor (by 17%: from 19.72 to 16.37 HV). Microstructurally, Dental Sand Pro and Tempocor have pores and inhomogeneities. Conclusion. It is most stable in the aquatic environment of Huge PMMA (CAD/CAM). Sinma-M (hot polymerization) also demonstrates high stability. Dental Sand Pro 3D printing material requires optimization of post-polymerization modes. Tempocor (cold curing) is the least water-resistant, and its use for long-term temporary restoration is limited. Surface hardness is an informative criterion for preclinical assessment of the reliability of temporary restorations.
- 18 June 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (3) , 5-9
The effect of autoclaving sterilization on the physical-mechanical properties of samples made of photopolymer materials
Objective. A comprehensive assessment of the effect of the standard autoclaving sterilization procedure on the physico-mechanical properties of samples made from domestic photopolymer material using stereolithographic 3D printing. Materials and methods. To form a representative sample, a batch of samples printed on a 3D stereolithographic system with a 0.05 mm pitch was used. The samples were divided into two groups: group No. 1 (n=10), which was not sterilized, and group No. 2 (n=10), which underwent a full cycle of autoclaving in the standard mode, the mechanical test procedure consisted of The values of the following parameters are: flexural strength (σ, MPa), flexural modulus of elasticity (Emod, MPa) and deformation (mm) to the moment of fracture. Results. A tendency to decrease bending strength by an average of 1.05% was revealed, from 140±11 MPa for non—autoclaved samples to 138±7 MPa for samples after autoclaving. The modulus of elasticity, which is the main indicator of the strength of the material, decreased by an average of 1.66% from 3242±228 to 3188±152 Mpa. Conclusion. The data obtained allow us to recommend the use of the studied domestic photopolymer material in combination with printing with a minimum step of 0.05 mm and subsequent sterilization by autoclaving in the standard mode as a technologically sound and clinically safe protocol for surgical dentistry.
- 18 June 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (3) , 5-9
The effect of autoclaving sterilization on the physical-mechanical properties of samples made of photopolymer materials
Objective. A comprehensive assessment of the effect of the standard autoclaving sterilization procedure on the physico-mechanical properties of samples made from domestic photopolymer material using stereolithographic 3D printing. Materials and methods. To form a representative sample, a batch of samples printed on a 3D stereolithographic system with a 0.05 mm pitch was used. The samples were divided into two groups: group No. 1 (n=10), which was not sterilized, and group No. 2 (n=10), which underwent a full cycle of autoclaving in the standard mode, the mechanical test procedure consisted of The values of the following parameters are: flexural strength (σ, MPa), flexural modulus of elasticity (Emod, MPa) and deformation (mm) to the moment of fracture. Results. A tendency to decrease bending strength by an average of 1.05% was revealed, from 140±11 MPa for non—autoclaved samples to 138±7 MPa for samples after autoclaving. The modulus of elasticity, which is the main indicator of the strength of the material, decreased by an average of 1.66% from 3242±228 to 3188±152 Mpa. Conclusion. The data obtained allow us to recommend the use of the studied domestic photopolymer material in combination with printing with a minimum step of 0.05 mm and subsequent sterilization by autoclaving in the standard mode as a technologically sound and clinically safe protocol for surgical dentistry.
- 18 June 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (3) , 10-14
Comparative assessment of the strength of dental polymeric materials for temporary orthopedic restorations
Objective. The aim of the study Conducting a comparative analysis of the strength characteristics of model samples of modern polymer materials used for the manufacture of temporary orthopedic structures. Materials and methods. The materials used were Dental Sand Pro (HARZ Labs, Russia) and Huge PMMA Monolayer (Huge, China). Dental SAND PRO material is positioned as a ceramic-filled polymer material designed for 3D printing of temporary crowns and bridge-like structures for long-term wear. As part of the experimental part of the work, models were developed and manufactured for conducting a series of comparative compression tests. Two modern production technologies are compared: milling from ready-made factory blocks (CAD/CAM) and 3D printing. Results. Tests have shown that structures made of HUGE PMMA Monolayer material using CAD/CAM technology have higher mechanical strength compared to crowns made of HARZ Labs “Dental Sand Pro” material made by 3D printing. The destructive load of milled samples from HUGE PMMA is 2—4 times higher. Model molar crowns also had higher values for milled samples. Bridge-like prostheses made by milling could withstand about 1600 N, and 3D printing — about 500 N (p<0.05). Conclusion. Temporary structures made by milling from ready-made polymer blocks have a sufficient margin of safety for use in all areas of the dentition. In turn, 3D-printed structures, due to their lower strength characteristics, should be used mainly in the area of frontal teeth and premolars, where the load is significantly.
- 18 June 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (3) , 10-14
Comparative assessment of the strength of dental polymeric materials for temporary orthopedic restorations
Objective. The aim of the study Conducting a comparative analysis of the strength characteristics of model samples of modern polymer materials used for the manufacture of temporary orthopedic structures. Materials and methods. The materials used were Dental Sand Pro (HARZ Labs, Russia) and Huge PMMA Monolayer (Huge, China). Dental SAND PRO material is positioned as a ceramic-filled polymer material designed for 3D printing of temporary crowns and bridge-like structures for long-term wear. As part of the experimental part of the work, models were developed and manufactured for conducting a series of comparative compression tests. Two modern production technologies are compared: milling from ready-made factory blocks (CAD/CAM) and 3D printing. Results. Tests have shown that structures made of HUGE PMMA Monolayer material using CAD/CAM technology have higher mechanical strength compared to crowns made of HARZ Labs “Dental Sand Pro” material made by 3D printing. The destructive load of milled samples from HUGE PMMA is 2—4 times higher. Model molar crowns also had higher values for milled samples. Bridge-like prostheses made by milling could withstand about 1600 N, and 3D printing — about 500 N (p<0.05). Conclusion. Temporary structures made by milling from ready-made polymer blocks have a sufficient margin of safety for use in all areas of the dentition. In turn, 3D-printed structures, due to their lower strength characteristics, should be used mainly in the area of frontal teeth and premolars, where the load is significantly.
- Open Access
- 5 May 2026
- Published by Periodontal Association - RPA in Pediatric dentistry and dental prophylaxis
- Vol. 26 (1) , 11-18
Evaluation of the bond strength of zirconia crowns to primary tooth dentin depending on the luting cement
Relevance . According to the World Health Organization, dental caries in primary teeth is the most common chronic disease in childhood, affecting 514 million children worldwide in 2022. In children aged 0–5 years, the first signs of carious lesions are typically detected in the anterior teeth, with the maxillary incisors and canines being most frequently affected. Various approaches are available for restoring primary teeth; however, in cases of extensive crown destruction, prefabricated full-coverage crowns, including zirconia crowns, are preferred. Successful treatment requires reliable bonding of crowns to primary tooth dentin using luting cements. Luting cements must meet several requirements, including adequate adhesion to hard dental tissues and indirect restorations, biocompatibility, and favorable esthetic properties. This study evaluated the bond strength of zirconia crowns to primary tooth dentin using different luting cements. Objective . To evaluate the bond strength of zirconia crowns to primary tooth dentin using different luting cements. Materials and methods . The bond strength of zirconia specimens to primary tooth dentin was evaluated using different luting cements. Sixty sections of primary teeth extracted for clinical indications and mechanically prepared were used as test specimens. Bond strength was assessed using shear and tensile bond strength tests. Results. The self-adhesive resin cement Maxcem Elite demonstrated high bond strength to both zirconia and primary tooth dentin in the shear and tensile tests: 5.95 [4.33; 8.78] MPa and 13.94 [11.95; 17.88] MPa, respectively. Specimens bonded with the glass ionomer luting cement GC Fuji I also showed good results in the shear test: 5.15 [3.38; 7.70] MPa; however, tensile bond strength was low: 0.90 [0.80; 1.40] MPa. Bonding of primary tooth dentin to zirconia using the glass ionomer cement CEMION-F showed lower values in both shear and tensile tests: 1.60 [1.00; 2.45] MPa and 0.49 [0.30; 1.26] MPa, respectively. Conclusion . The self-adhesive resin cement Maxcem Elite provided the highest bond strength between zirconia and primary tooth dentin. The glass ionomer cement Fuji I also demonstrated favorable bond strength when used to lute zirconia to primary tooth dentin. The glass ionomer cement CEMION-F showed lower bond strength.
- 5 May 2026
- Published by Periodontal Association - RPA in Pediatric dentistry and dental prophylaxis
- Vol. 26 (1) , 11-18
Open AccessEvaluation of the bond strength of zirconia crowns to primary tooth dentin depending on the luting cement
Relevance . According to the World Health Organization, dental caries in primary teeth is the most common chronic disease in childhood, affecting 514 million children worldwide in 2022. In children aged 0–5 years, the first signs of carious lesions are typically detected in the anterior teeth, with the maxillary incisors and canines being most frequently affected. Various approaches are available for restoring primary teeth; however, in cases of extensive crown destruction, prefabricated full-coverage crowns, including zirconia crowns, are preferred. Successful treatment requires reliable bonding of crowns to primary tooth dentin using luting cements. Luting cements must meet several requirements, including adequate adhesion to hard dental tissues and indirect restorations, biocompatibility, and favorable esthetic properties. This study evaluated the bond strength of zirconia crowns to primary tooth dentin using different luting cements. Objective . To evaluate the bond strength of zirconia crowns to primary tooth dentin using different luting cements. Materials and methods . The bond strength of zirconia specimens to primary tooth dentin was evaluated using different luting cements. Sixty sections of primary teeth extracted for clinical indications and mechanically prepared were used as test specimens. Bond strength was assessed using shear and tensile bond strength tests. Results. The self-adhesive resin cement Maxcem Elite demonstrated high bond strength to both zirconia and primary tooth dentin in the shear and tensile tests: 5.95 [4.33; 8.78] MPa and 13.94 [11.95; 17.88] MPa, respectively. Specimens bonded with the glass ionomer luting cement GC Fuji I also showed good results in the shear test: 5.15 [3.38; 7.70] MPa; however, tensile bond strength was low: 0.90 [0.80; 1.40] MPa. Bonding of primary tooth dentin to zirconia using the glass ionomer cement CEMION-F showed lower values in both shear and tensile tests: 1.60 [1.00; 2.45] MPa and 0.49 [0.30; 1.26] MPa, respectively. Conclusion . The self-adhesive resin cement Maxcem Elite provided the highest bond strength between zirconia and primary tooth dentin. The glass ionomer cement Fuji I also demonstrated favorable bond strength when used to lute zirconia to primary tooth dentin. The glass ionomer cement CEMION-F showed lower bond strength.
- 27 April 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (2) , 5-8
Comparative analysis of the manufacturing strength of surgical templates made from Dental Yellow Clear PRO photopolymer material (HARZ Labs)
Objective.The aim of the study was to study the physico-mechanical properties of the photopolymer material Dental Yellow Clear PRO (HARZ Labs) and to evaluate its clinical applicability for the manufacture of surgical templates by stereolithographic 3D printing. According to the manufacturer, Dental Yellow Clear PRO (HARZ Labs) is a mixture based on urethandimethacrylate (50—70%), polyethylene glycol dimethacrylate (30—50%) with additives of 2-hydroxypropylmethacrylate and contains photo initiators. The material is available as a liquid of varying transparency and color, odorless, with a viscosity of 800—1000 and a flash point above 100 °C. The main purpose is the production of surgical templates by stereolithographic printing. The data obtained as a result of the tests indicate that when the simultaneously cured layer is halved during 3D printing, the values of strength indicators increase and at the same time the possibilities of deformation of the samples increase.Thus, samples made with a lower layer thickness and a printing step of 0.05 mm instead of 0.1 mm showed higher values of bending strength and modulus of elasticity, on average 24% higher, and the deformation of samples during fracture also increased by 27%. At a printing step of 0.05 mm: the bending strength reaches 124 MPa, and the modulus of elasticity is 2780 MPa. The test results allow us to conclude that Dental Yellow Clear PRO (HARZ Labs) is a promising material for manufacturing surgical templates. It combines sufficiently high mechanical strength and predictable behavior under the influence of functional loads.
- 27 April 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (2) , 5-8
Comparative analysis of the manufacturing strength of surgical templates made from Dental Yellow Clear PRO photopolymer material (HARZ Labs)
Objective.The aim of the study was to study the physico-mechanical properties of the photopolymer material Dental Yellow Clear PRO (HARZ Labs) and to evaluate its clinical applicability for the manufacture of surgical templates by stereolithographic 3D printing. According to the manufacturer, Dental Yellow Clear PRO (HARZ Labs) is a mixture based on urethandimethacrylate (50—70%), polyethylene glycol dimethacrylate (30—50%) with additives of 2-hydroxypropylmethacrylate and contains photo initiators. The material is available as a liquid of varying transparency and color, odorless, with a viscosity of 800—1000 and a flash point above 100 °C. The main purpose is the production of surgical templates by stereolithographic printing. The data obtained as a result of the tests indicate that when the simultaneously cured layer is halved during 3D printing, the values of strength indicators increase and at the same time the possibilities of deformation of the samples increase.Thus, samples made with a lower layer thickness and a printing step of 0.05 mm instead of 0.1 mm showed higher values of bending strength and modulus of elasticity, on average 24% higher, and the deformation of samples during fracture also increased by 27%. At a printing step of 0.05 mm: the bending strength reaches 124 MPa, and the modulus of elasticity is 2780 MPa. The test results allow us to conclude that Dental Yellow Clear PRO (HARZ Labs) is a promising material for manufacturing surgical templates. It combines sufficiently high mechanical strength and predictable behavior under the influence of functional loads.
- 27 April 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (2) , 17-24
FDM printing in the correction of temporary orthopedic structures: a study of adhesive strength and tightness of the joint
Objective. The aim of this study was to improve the quality of prosthetic treatment through the development of methods for correction and modification of temporary prosthetic constructions using FDM printing. Materials and Methods. Substrates made of acrylic resins Belacryl M GO and Tempron were used. Elements made of various polymers (PLA, ABS, PC, PMMA) produced by FDM printing were applied to their surfaces. Adhesive strength was evaluated using a Zwick Roell Z010 testing machine under shear and tensile tests, while the microleakage of the bonding zone was assessed with dye penetration. Results: Preliminary surface treatment with methyl methacrylate monomer provided a statistically significant increase in bond strength (p<0.05). The highest values were demonstrated by PLA (up to 137.5±27.1 MPa) and ABS (up to 179.8±41.5 MPa). Microleakage testing revealed the absence of dye penetration in the bonding zone after monomer treatment. Conclusion: The proposed method of correction using FDM printing combined with preliminary substrate treatment improves the mechanical strength and sealing properties of the bonds, confirming its clinical potential for the repair and reinforcement of temporary prostheses.
- 27 April 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (2) , 17-24
FDM printing in the correction of temporary orthopedic structures: a study of adhesive strength and tightness of the joint
Objective. The aim of this study was to improve the quality of prosthetic treatment through the development of methods for correction and modification of temporary prosthetic constructions using FDM printing. Materials and Methods. Substrates made of acrylic resins Belacryl M GO and Tempron were used. Elements made of various polymers (PLA, ABS, PC, PMMA) produced by FDM printing were applied to their surfaces. Adhesive strength was evaluated using a Zwick Roell Z010 testing machine under shear and tensile tests, while the microleakage of the bonding zone was assessed with dye penetration. Results: Preliminary surface treatment with methyl methacrylate monomer provided a statistically significant increase in bond strength (p<0.05). The highest values were demonstrated by PLA (up to 137.5±27.1 MPa) and ABS (up to 179.8±41.5 MPa). Microleakage testing revealed the absence of dye penetration in the bonding zone after monomer treatment. Conclusion: The proposed method of correction using FDM printing combined with preliminary substrate treatment improves the mechanical strength and sealing properties of the bonds, confirming its clinical potential for the repair and reinforcement of temporary prostheses.
- 25 March 2026
- Published by Stomatology for All - International Dental Review in Stomatology for all / International Dental Review
- No. 1(114)
In vitro study of adhesive fixation of metal brackets
The study investigated the micropermeability of the tooth-adhesive-bracket complex when using metal self-ligating and ligature brackets with «CompoFix Ortho» (Russia) and «Transbond XT» (USA) adhesives. Forty premolars removed for orthodontic reasons and free of caries were used. After the braces were photopolymerized, the teeth were stored in distilled water at room temperature for 1 month, and then subjected to thermal cycling in deionized water at a temperature of 5 ± 2°C to 55 ± 2°C for 500 cycles with a dwell time of 30 seconds and a transfer time of 10 seconds. After thorough washing with distilled water, the samples were air-dried and embedded in acrylic plastic. It was revealed that the average strength of the adhesive joint when metal braces are detached from tooth enamel, using the composite “CompoFix Ortho” (RF) and the foreign equivalent “Transbond XT” (USA) – 7,6±0,3 MPa, does not statistically differ (p≥0,05), but statistically differs between self-ligated (7,8±0,2 MРa) and ligature braces (7,1±0,15 MРa) (p<0,05). It was contirmed that the metal braces of different types of ligations cause an increase in the micropermeability of the enamel in the area of the adhesive connection of the fixing material of the bracket with the occlusal and gingival sides of the samples, which can lead to a decrease in the strength of the adhesive connection and the appearance of demineralization: the formation of white spots on the enamel. The study showed no statistical difference between the levels of microleakage of the two compared adhesive systems.
- 25 March 2026
- Published by Stomatology for All - International Dental Review in Stomatology for all / International Dental Review
- No. 1(114)
In vitro study of adhesive fixation of metal brackets
The study investigated the micropermeability of the tooth-adhesive-bracket complex when using metal self-ligating and ligature brackets with «CompoFix Ortho» (Russia) and «Transbond XT» (USA) adhesives. Forty premolars removed for orthodontic reasons and free of caries were used. After the braces were photopolymerized, the teeth were stored in distilled water at room temperature for 1 month, and then subjected to thermal cycling in deionized water at a temperature of 5 ± 2°C to 55 ± 2°C for 500 cycles with a dwell time of 30 seconds and a transfer time of 10 seconds. After thorough washing with distilled water, the samples were air-dried and embedded in acrylic plastic. It was revealed that the average strength of the adhesive joint when metal braces are detached from tooth enamel, using the composite “CompoFix Ortho” (RF) and the foreign equivalent “Transbond XT” (USA) – 7,6±0,3 MPa, does not statistically differ (p≥0,05), but statistically differs between self-ligated (7,8±0,2 MРa) and ligature braces (7,1±0,15 MРa) (p<0,05). It was contirmed that the metal braces of different types of ligations cause an increase in the micropermeability of the enamel in the area of the adhesive connection of the fixing material of the bracket with the occlusal and gingival sides of the samples, which can lead to a decrease in the strength of the adhesive connection and the appearance of demineralization: the formation of white spots on the enamel. The study showed no statistical difference between the levels of microleakage of the two compared adhesive systems.
- 26 February 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (1) , 5-9
Application of the instrumented indentation method in vitro for determining the basic physico-mechanical properties of natural tooth hard tissues
Objective. The aim of the study was to determine the physical and mechanical properties of dental hard tissues, enamel, and dentin, in vitro. Materials and methods. The study material consisted of premolars extracted for medical reasons, pre-sawn in half in the sagittal (longitudinal) direction, followed by fixation in a plastic block and polishing to a mirror shine to obtain sections containing enamel, dentin, and the dentinoenamel junction area. The study method consisted of testing the prepared tooth sections by nanoindentation using a NaNo Hardness Tester with a triangular pyramidal Berkovich indenter. Results. The microhardness and elastic modulus of enamel and dentin, as well as the dentin-enamel junction area, were determined. The displacement indices of the surface layers of dentin and enamel under maximum load and after unloading, determined during indentation, made it possible to determine the elastic properties of the tested dental tissues based on the coefficient of elastic recovery. Conclusion. The microhardness, elastic modulus, and elastic recovery coefficient of dentin and enamel obtained as a result of an in vitro study using the nanoindentation method showed good reproducibility of the test results and consistency of the obtained nanoscale indicators with the results of tests on macro-samples using standard methods.
- 26 February 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (1) , 5-9
Application of the instrumented indentation method in vitro for determining the basic physico-mechanical properties of natural tooth hard tissues
Objective. The aim of the study was to determine the physical and mechanical properties of dental hard tissues, enamel, and dentin, in vitro. Materials and methods. The study material consisted of premolars extracted for medical reasons, pre-sawn in half in the sagittal (longitudinal) direction, followed by fixation in a plastic block and polishing to a mirror shine to obtain sections containing enamel, dentin, and the dentinoenamel junction area. The study method consisted of testing the prepared tooth sections by nanoindentation using a NaNo Hardness Tester with a triangular pyramidal Berkovich indenter. Results. The microhardness and elastic modulus of enamel and dentin, as well as the dentin-enamel junction area, were determined. The displacement indices of the surface layers of dentin and enamel under maximum load and after unloading, determined during indentation, made it possible to determine the elastic properties of the tested dental tissues based on the coefficient of elastic recovery. Conclusion. The microhardness, elastic modulus, and elastic recovery coefficient of dentin and enamel obtained as a result of an in vitro study using the nanoindentation method showed good reproducibility of the test results and consistency of the obtained nanoscale indicators with the results of tests on macro-samples using standard methods.
- 19 November 2025
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 29 (6) , 445-452
Physicomechanical properties of modern Russian materials used for 3D printing of surgical guides: an uncontrolled laboratory study
BACKGROUND: The relevance of this study is supported by the integration of modern technologies into dental practice, including the use of surgical guides. Unfortunately, in recent years, foreign materials have often been either unavailable for purchase or prohibitively expensive. The use of materials produced in Russia ensures consistent availability, faster delivery, and competitive pricing. This study evaluates the physicomechanical properties of Russian-made materials used for fabricating surgical guides and determines how these properties change after sterilization by autoclaving. AIM: This work aimed to assess the physicomechanical properties of Russian 3D printing materials intended for surgical guide fabrication before and after autoclave sterilization. METHODS: Three types of domestically produced photopolymer resins were tested. Hardness, flexural modulus, and fracture toughness were evaluated before and after sterilization. RESULTS: Flexural testing demonstrated that all three groups of Russian materials are suitable for use as finished surgical guides in accordance with the requirements of GOST R 71413-2024 Dentistry. Base Polymers. Part 2: Polymeric Orthodontic Base Materials. General Technical Requirements and Test Methods, which specifies a minimum flexural strength of 50 MPa and a minimum elastic modulus of 1500 MPa for the fabrication of bases intended for prolonged intraoral use. All tested material groups met these requirements, except the group 1 (“wet”) samples. However, because a surgical guide does not stay in the oral cavity for long and does not have sufficient time to absorb moisture, and because the mechanical load on a navigation guide is substantially lower, group 1 materials may also be recommended for guide fabrication. Autoclaved samples from groups 1 and 2 demonstrated high fracture toughness values. In turn, group 3 samples remained stable, which may indicate a homogeneous internal structure of the material. CONCLUSION: Material strength increased after autoclave sterilization. All tested material groups are suitable for fabrication of surgical guides, with group 3 demonstrating the most stable physicomechanical properties.
- 19 November 2025
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 29 (6) , 445-452
Physicomechanical properties of modern Russian materials used for 3D printing of surgical guides: an uncontrolled laboratory study
BACKGROUND: The relevance of this study is supported by the integration of modern technologies into dental practice, including the use of surgical guides. Unfortunately, in recent years, foreign materials have often been either unavailable for purchase or prohibitively expensive. The use of materials produced in Russia ensures consistent availability, faster delivery, and competitive pricing. This study evaluates the physicomechanical properties of Russian-made materials used for fabricating surgical guides and determines how these properties change after sterilization by autoclaving. AIM: This work aimed to assess the physicomechanical properties of Russian 3D printing materials intended for surgical guide fabrication before and after autoclave sterilization. METHODS: Three types of domestically produced photopolymer resins were tested. Hardness, flexural modulus, and fracture toughness were evaluated before and after sterilization. RESULTS: Flexural testing demonstrated that all three groups of Russian materials are suitable for use as finished surgical guides in accordance with the requirements of GOST R 71413-2024 Dentistry. Base Polymers. Part 2: Polymeric Orthodontic Base Materials. General Technical Requirements and Test Methods, which specifies a minimum flexural strength of 50 MPa and a minimum elastic modulus of 1500 MPa for the fabrication of bases intended for prolonged intraoral use. All tested material groups met these requirements, except the group 1 (“wet”) samples. However, because a surgical guide does not stay in the oral cavity for long and does not have sufficient time to absorb moisture, and because the mechanical load on a navigation guide is substantially lower, group 1 materials may also be recommended for guide fabrication. Autoclaved samples from groups 1 and 2 demonstrated high fracture toughness values. In turn, group 3 samples remained stable, which may indicate a homogeneous internal structure of the material. CONCLUSION: Material strength increased after autoclave sterilization. All tested material groups are suitable for fabrication of surgical guides, with group 3 demonstrating the most stable physicomechanical properties.
- Open Access
- 1 March 2025
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 29 (1) , 13-20
Adhesive strength of cervical composite restorations
BACKGROUND: The effectiveness of universal adhesives for restorations remains a subject of debate. The long-term reliability of adhesive bonds in cervical cavities, depending on the functional role of the tooth (chewing vs. biting), has not been sufficiently studied. Numerous studies on ensuring reliable adhesion indicate that this topic remains relevant for further investigation. AIM: To assess the adhesive bond strength of composite restorations to hard dental tissues in laboratory samples of anterior and posterior teeth before and after thermocycling. MATERIALS AND METHODS: The study included extracted teeth (n = 60) obtained from elderly (60–75 years) and senile (75–90 years) patients due to periodontal indications. The teeth were divided into two groups (n = 30 each) based on the adhesive system used: Group 1, Universal Bond II; Group 2, OptiBond Solo Plus. Both groups used the flowable photopolymer EsFlow and the universal composite Point 4. Each group was further divided into two subgroups based on function: anterior (A) and posterior (P) teeth (n = 15 in each), and subsequently, into two additional subgroups based on thermocycling: (a) before thermocycling and (b) after thermocycling. Cervical cavities (5 × 5 × 3 mm) were prepared in all samples using a high-speed dental handpiece under water cooling. The specimens underwent 1000 thermocycles alternating for 30 s each (with a 30-second intermediate interval) at a temperature regime of (5 ± 2) °C and (60 ± 2) °C. The adhesive strength of the teeth was then evaluated under compressive load. RESULTS: The adhesive strength under compression in subgroups 1Aa and 2Aa was 1663.6 [1574.6; 2175.1] N and 2151.5 [967.9; 3970.3] N, respectively. The difference between them was statistically insignificant (p = 0.538), confirming group homogeneity. The adhesive strength values in subgroups 1Ab and 2Ab were 1353.3 [1219.2; 2096.8] N and 1620.7 [847.2; 2434.7] N, respectively (p = 0.868). Statistically significant differences were observed between subgroups 1Aa and 1Ab (p = 0.017) and between 2Aa and 2Ab (p = 0.017). In the posterior tooth groups, the adhesive strength in subgroups 1Pa and 2Pa was 4100.0 [2818.1; 48401.4] N and 3800.0 [2000.0; 4500.0] N, respectively (p = 0.476), indicating the effectiveness of both adhesive systems. In subgroups 1Pb and 2Pb, the adhesive strength was 3479.5 [2708.8; 3995.6] N and 1999.0 [1646.3; 3120.8] N, respectively (p = 0.153), confirming the effectiveness of adhesion and the integrity of the restoration–tooth complex. CONCLUSION: Posterior teeth withstand higher loads compared to anterior teeth. A decrease in bond strength was observed in all groups after thermocycling, which is influenced not only by the type of adhesive system but also by the anatomical characteristics of posterior teeth, including their shape, surface area, and relief.
- 1 March 2025
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 29 (1) , 13-20
Open AccessAdhesive strength of cervical composite restorations
BACKGROUND: The effectiveness of universal adhesives for restorations remains a subject of debate. The long-term reliability of adhesive bonds in cervical cavities, depending on the functional role of the tooth (chewing vs. biting), has not been sufficiently studied. Numerous studies on ensuring reliable adhesion indicate that this topic remains relevant for further investigation. AIM: To assess the adhesive bond strength of composite restorations to hard dental tissues in laboratory samples of anterior and posterior teeth before and after thermocycling. MATERIALS AND METHODS: The study included extracted teeth (n = 60) obtained from elderly (60–75 years) and senile (75–90 years) patients due to periodontal indications. The teeth were divided into two groups (n = 30 each) based on the adhesive system used: Group 1, Universal Bond II; Group 2, OptiBond Solo Plus. Both groups used the flowable photopolymer EsFlow and the universal composite Point 4. Each group was further divided into two subgroups based on function: anterior (A) and posterior (P) teeth (n = 15 in each), and subsequently, into two additional subgroups based on thermocycling: (a) before thermocycling and (b) after thermocycling. Cervical cavities (5 × 5 × 3 mm) were prepared in all samples using a high-speed dental handpiece under water cooling. The specimens underwent 1000 thermocycles alternating for 30 s each (with a 30-second intermediate interval) at a temperature regime of (5 ± 2) °C and (60 ± 2) °C. The adhesive strength of the teeth was then evaluated under compressive load. RESULTS: The adhesive strength under compression in subgroups 1Aa and 2Aa was 1663.6 [1574.6; 2175.1] N and 2151.5 [967.9; 3970.3] N, respectively. The difference between them was statistically insignificant (p = 0.538), confirming group homogeneity. The adhesive strength values in subgroups 1Ab and 2Ab were 1353.3 [1219.2; 2096.8] N and 1620.7 [847.2; 2434.7] N, respectively (p = 0.868). Statistically significant differences were observed between subgroups 1Aa and 1Ab (p = 0.017) and between 2Aa and 2Ab (p = 0.017). In the posterior tooth groups, the adhesive strength in subgroups 1Pa and 2Pa was 4100.0 [2818.1; 48401.4] N and 3800.0 [2000.0; 4500.0] N, respectively (p = 0.476), indicating the effectiveness of both adhesive systems. In subgroups 1Pb and 2Pb, the adhesive strength was 3479.5 [2708.8; 3995.6] N and 1999.0 [1646.3; 3120.8] N, respectively (p = 0.153), confirming the effectiveness of adhesion and the integrity of the restoration–tooth complex. CONCLUSION: Posterior teeth withstand higher loads compared to anterior teeth. A decrease in bond strength was observed in all groups after thermocycling, which is influenced not only by the type of adhesive system but also by the anatomical characteristics of posterior teeth, including their shape, surface area, and relief.