Irina Ya. Poyurovskaya
Research Subjects
Irina Ya. Poyurovskaya has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Fedor S. Rusanov
Central Research Institute of Dentistry and Maxillofacial Surgery
6 shared publications - Fedor F. Losev
Central research Institute of dentistry and maxillofacial surgery Ministry of health of Russia
5 shared publications - Tat'Yana Vladislavovna Brailovskaya
National Medical Research Centre for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia; Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation
4 shared publications - A.F. Sharganov
National Medical Research Center for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia
2 shared publications - A. V. Korshunova
Central Research Institute of Dentistry and Maxillofacial Surgery
1 shared publication - A.A. Muzaeva
Central Research Institute of Dentistry and Maxillofacial Surgery
1 shared publication
Latest Publications
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 13-18
Comparative analysis of microhardness of polymeric materials for temporary restorations manufactured using different technologies
Objective. Comparative study of the surface hardness of polymer materials for temporary crowns, differing in composition and manufacturing technology, in a dry state and after exposure to an aqueous medium. Material and methods. 4 materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot curing), Tempocor (cold curing). The disc-shaped samples were polished and kept in dry conditions or distilled water (37 °C, 7 days). The Vickers hardness was measured on a Duramin-20 microhardness tester (load 25 g, exposure 15 s). Statistical processing is the Student’s t-test. Results. In the dry state, all materials showed similar hardness (19—22 HV). The smallest decrease in hardness after water was observed in Huge PMMA (<7%) and Sinma-M (~3%). Dental Sand Pro showed a decrease of 12.4%. The maximum drop was in Tempocor (by 17%: from 19.72 to 16.37 HV). Microstructurally, Dental Sand Pro and Tempocor have pores and inhomogeneities. Conclusion. It is most stable in the aquatic environment of Huge PMMA (CAD/CAM). Sinma-M (hot polymerization) also demonstrates high stability. Dental Sand Pro 3D printing material requires optimization of post-polymerization modes. Tempocor (cold curing) is the least water-resistant, and its use for long-term temporary restoration is limited. Surface hardness is an informative criterion for preclinical assessment of the reliability of temporary restorations.
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 13-18
Comparative analysis of microhardness of polymeric materials for temporary restorations manufactured using different technologies
Objective. Comparative study of the surface hardness of polymer materials for temporary crowns, differing in composition and manufacturing technology, in a dry state and after exposure to an aqueous medium. Material and methods. 4 materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot curing), Tempocor (cold curing). The disc-shaped samples were polished and kept in dry conditions or distilled water (37 °C, 7 days). The Vickers hardness was measured on a Duramin-20 microhardness tester (load 25 g, exposure 15 s). Statistical processing is the Student’s t-test. Results. In the dry state, all materials showed similar hardness (19—22 HV). The smallest decrease in hardness after water was observed in Huge PMMA (<7%) and Sinma-M (~3%). Dental Sand Pro showed a decrease of 12.4%. The maximum drop was in Tempocor (by 17%: from 19.72 to 16.37 HV). Microstructurally, Dental Sand Pro and Tempocor have pores and inhomogeneities. Conclusion. It is most stable in the aquatic environment of Huge PMMA (CAD/CAM). Sinma-M (hot polymerization) also demonstrates high stability. Dental Sand Pro 3D printing material requires optimization of post-polymerization modes. Tempocor (cold curing) is the least water-resistant, and its use for long-term temporary restoration is limited. Surface hardness is an informative criterion for preclinical assessment of the reliability of temporary restorations.
- 12 August 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (4)
The influence of composition and application technology of polymeric materials for temporary restorations in prosthetic dentistry on water sorption and solubility indicators
Objective. Comparative assessment of water absorption and solubility of polymer materials for temporary restorations, differing in composition and technology of application (CAD/CAM, 3D printing, traditional analog method). Materials and methods. Four materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot polymerization) and Tempokor Automix (chemical curing). Samples in the form of discs (n= 4-8 per group) were made according to the requirements of GOST R 71412-2024. Water absorption (p_w) and solubility (p_s) tests were carried out in distilled water at a temperature of 37 ± 1 °C for 7 days. The statistical analysis was performed using the Student’s t-test. Results. Statistically significant intergroup differences were found (p<0.05). The highest water absorption was observed in the Dental Sand Pro 3D printing material (40.04±1.59 micrograms/mm3), which corresponds to the upper limit of the standard value. The values of p_w for Huge PMMA (26.76±1.70 micrograms/mm3) and Sigma-M (24.05±2.65 micrograms/mm3) are below the established limit. The solubility of Sinma-M (11.21±3.17 micrograms/mm3) exceeded the standard value (7.5 micrograms/mm3) and was significantly higher than that of Huge PMMA (0.78±0.16 micrograms/mm3) and Dental Sand Pro (4.32±1.44 micrograms/mm3). The Tempocor material showed satisfactory results in both parameters. Conclusion. The water absorption and solubility of polymer materials for temporary restorations significantly depend on both the chemical composition and the manufacturing technology. Milled PMMA (CAD/CAM) demonstrated the greatest stability, while traditional materials showed high variability in properties. The results obtained should be taken into account in the clinical selection of the material to ensure the long-term success of orthopedic treatment.
- 12 August 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (4)
The influence of composition and application technology of polymeric materials for temporary restorations in prosthetic dentistry on water sorption and solubility indicators
Objective. Comparative assessment of water absorption and solubility of polymer materials for temporary restorations, differing in composition and technology of application (CAD/CAM, 3D printing, traditional analog method). Materials and methods. Four materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot polymerization) and Tempokor Automix (chemical curing). Samples in the form of discs (n= 4-8 per group) were made according to the requirements of GOST R 71412-2024. Water absorption (p_w) and solubility (p_s) tests were carried out in distilled water at a temperature of 37 ± 1 °C for 7 days. The statistical analysis was performed using the Student’s t-test. Results. Statistically significant intergroup differences were found (p<0.05). The highest water absorption was observed in the Dental Sand Pro 3D printing material (40.04±1.59 micrograms/mm3), which corresponds to the upper limit of the standard value. The values of p_w for Huge PMMA (26.76±1.70 micrograms/mm3) and Sigma-M (24.05±2.65 micrograms/mm3) are below the established limit. The solubility of Sinma-M (11.21±3.17 micrograms/mm3) exceeded the standard value (7.5 micrograms/mm3) and was significantly higher than that of Huge PMMA (0.78±0.16 micrograms/mm3) and Dental Sand Pro (4.32±1.44 micrograms/mm3). The Tempocor material showed satisfactory results in both parameters. Conclusion. The water absorption and solubility of polymer materials for temporary restorations significantly depend on both the chemical composition and the manufacturing technology. Milled PMMA (CAD/CAM) demonstrated the greatest stability, while traditional materials showed high variability in properties. The results obtained should be taken into account in the clinical selection of the material to ensure the long-term success of orthopedic treatment.
- 18 June 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (3) , 5-9
The effect of autoclaving sterilization on the physical-mechanical properties of samples made of photopolymer materials
Objective. A comprehensive assessment of the effect of the standard autoclaving sterilization procedure on the physico-mechanical properties of samples made from domestic photopolymer material using stereolithographic 3D printing. Materials and methods. To form a representative sample, a batch of samples printed on a 3D stereolithographic system with a 0.05 mm pitch was used. The samples were divided into two groups: group No. 1 (n=10), which was not sterilized, and group No. 2 (n=10), which underwent a full cycle of autoclaving in the standard mode, the mechanical test procedure consisted of The values of the following parameters are: flexural strength (σ, MPa), flexural modulus of elasticity (Emod, MPa) and deformation (mm) to the moment of fracture. Results. A tendency to decrease bending strength by an average of 1.05% was revealed, from 140±11 MPa for non—autoclaved samples to 138±7 MPa for samples after autoclaving. The modulus of elasticity, which is the main indicator of the strength of the material, decreased by an average of 1.66% from 3242±228 to 3188±152 Mpa. Conclusion. The data obtained allow us to recommend the use of the studied domestic photopolymer material in combination with printing with a minimum step of 0.05 mm and subsequent sterilization by autoclaving in the standard mode as a technologically sound and clinically safe protocol for surgical dentistry.
- 18 June 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (3) , 5-9
The effect of autoclaving sterilization on the physical-mechanical properties of samples made of photopolymer materials
Objective. A comprehensive assessment of the effect of the standard autoclaving sterilization procedure on the physico-mechanical properties of samples made from domestic photopolymer material using stereolithographic 3D printing. Materials and methods. To form a representative sample, a batch of samples printed on a 3D stereolithographic system with a 0.05 mm pitch was used. The samples were divided into two groups: group No. 1 (n=10), which was not sterilized, and group No. 2 (n=10), which underwent a full cycle of autoclaving in the standard mode, the mechanical test procedure consisted of The values of the following parameters are: flexural strength (σ, MPa), flexural modulus of elasticity (Emod, MPa) and deformation (mm) to the moment of fracture. Results. A tendency to decrease bending strength by an average of 1.05% was revealed, from 140±11 MPa for non—autoclaved samples to 138±7 MPa for samples after autoclaving. The modulus of elasticity, which is the main indicator of the strength of the material, decreased by an average of 1.66% from 3242±228 to 3188±152 Mpa. Conclusion. The data obtained allow us to recommend the use of the studied domestic photopolymer material in combination with printing with a minimum step of 0.05 mm and subsequent sterilization by autoclaving in the standard mode as a technologically sound and clinically safe protocol for surgical dentistry.
- 27 April 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (2) , 5-8
Comparative analysis of the manufacturing strength of surgical templates made from Dental Yellow Clear PRO photopolymer material (HARZ Labs)
Objective.The aim of the study was to study the physico-mechanical properties of the photopolymer material Dental Yellow Clear PRO (HARZ Labs) and to evaluate its clinical applicability for the manufacture of surgical templates by stereolithographic 3D printing. According to the manufacturer, Dental Yellow Clear PRO (HARZ Labs) is a mixture based on urethandimethacrylate (50—70%), polyethylene glycol dimethacrylate (30—50%) with additives of 2-hydroxypropylmethacrylate and contains photo initiators. The material is available as a liquid of varying transparency and color, odorless, with a viscosity of 800—1000 and a flash point above 100 °C. The main purpose is the production of surgical templates by stereolithographic printing. The data obtained as a result of the tests indicate that when the simultaneously cured layer is halved during 3D printing, the values of strength indicators increase and at the same time the possibilities of deformation of the samples increase.Thus, samples made with a lower layer thickness and a printing step of 0.05 mm instead of 0.1 mm showed higher values of bending strength and modulus of elasticity, on average 24% higher, and the deformation of samples during fracture also increased by 27%. At a printing step of 0.05 mm: the bending strength reaches 124 MPa, and the modulus of elasticity is 2780 MPa. The test results allow us to conclude that Dental Yellow Clear PRO (HARZ Labs) is a promising material for manufacturing surgical templates. It combines sufficiently high mechanical strength and predictable behavior under the influence of functional loads.
- 27 April 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (2) , 5-8
Comparative analysis of the manufacturing strength of surgical templates made from Dental Yellow Clear PRO photopolymer material (HARZ Labs)
Objective.The aim of the study was to study the physico-mechanical properties of the photopolymer material Dental Yellow Clear PRO (HARZ Labs) and to evaluate its clinical applicability for the manufacture of surgical templates by stereolithographic 3D printing. According to the manufacturer, Dental Yellow Clear PRO (HARZ Labs) is a mixture based on urethandimethacrylate (50—70%), polyethylene glycol dimethacrylate (30—50%) with additives of 2-hydroxypropylmethacrylate and contains photo initiators. The material is available as a liquid of varying transparency and color, odorless, with a viscosity of 800—1000 and a flash point above 100 °C. The main purpose is the production of surgical templates by stereolithographic printing. The data obtained as a result of the tests indicate that when the simultaneously cured layer is halved during 3D printing, the values of strength indicators increase and at the same time the possibilities of deformation of the samples increase.Thus, samples made with a lower layer thickness and a printing step of 0.05 mm instead of 0.1 mm showed higher values of bending strength and modulus of elasticity, on average 24% higher, and the deformation of samples during fracture also increased by 27%. At a printing step of 0.05 mm: the bending strength reaches 124 MPa, and the modulus of elasticity is 2780 MPa. The test results allow us to conclude that Dental Yellow Clear PRO (HARZ Labs) is a promising material for manufacturing surgical templates. It combines sufficiently high mechanical strength and predictable behavior under the influence of functional loads.
- 26 February 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (1) , 5-9
Application of the instrumented indentation method in vitro for determining the basic physico-mechanical properties of natural tooth hard tissues
Objective. The aim of the study was to determine the physical and mechanical properties of dental hard tissues, enamel, and dentin, in vitro. Materials and methods. The study material consisted of premolars extracted for medical reasons, pre-sawn in half in the sagittal (longitudinal) direction, followed by fixation in a plastic block and polishing to a mirror shine to obtain sections containing enamel, dentin, and the dentinoenamel junction area. The study method consisted of testing the prepared tooth sections by nanoindentation using a NaNo Hardness Tester with a triangular pyramidal Berkovich indenter. Results. The microhardness and elastic modulus of enamel and dentin, as well as the dentin-enamel junction area, were determined. The displacement indices of the surface layers of dentin and enamel under maximum load and after unloading, determined during indentation, made it possible to determine the elastic properties of the tested dental tissues based on the coefficient of elastic recovery. Conclusion. The microhardness, elastic modulus, and elastic recovery coefficient of dentin and enamel obtained as a result of an in vitro study using the nanoindentation method showed good reproducibility of the test results and consistency of the obtained nanoscale indicators with the results of tests on macro-samples using standard methods.
- 26 February 2026
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 105 (1) , 5-9
Application of the instrumented indentation method in vitro for determining the basic physico-mechanical properties of natural tooth hard tissues
Objective. The aim of the study was to determine the physical and mechanical properties of dental hard tissues, enamel, and dentin, in vitro. Materials and methods. The study material consisted of premolars extracted for medical reasons, pre-sawn in half in the sagittal (longitudinal) direction, followed by fixation in a plastic block and polishing to a mirror shine to obtain sections containing enamel, dentin, and the dentinoenamel junction area. The study method consisted of testing the prepared tooth sections by nanoindentation using a NaNo Hardness Tester with a triangular pyramidal Berkovich indenter. Results. The microhardness and elastic modulus of enamel and dentin, as well as the dentin-enamel junction area, were determined. The displacement indices of the surface layers of dentin and enamel under maximum load and after unloading, determined during indentation, made it possible to determine the elastic properties of the tested dental tissues based on the coefficient of elastic recovery. Conclusion. The microhardness, elastic modulus, and elastic recovery coefficient of dentin and enamel obtained as a result of an in vitro study using the nanoindentation method showed good reproducibility of the test results and consistency of the obtained nanoscale indicators with the results of tests on macro-samples using standard methods.
- 19 February 2024
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 103 (1) , 16-22
Laboratory evaluation of the effectiveness and safety of the Chairside Light Whitening System fläsh
The aim of the study. Optimization of methods for treating dental discoloration using whitening systems based on hydrogen peroxide by laboratory studying their chemical properties. Material and methods. The effectiveness of the bleaching system was assessed by quantitatively assessing the color change of model samples of hydroxyapatite (HAP) in the CIE L*a*b* system on a Spectron-M color analyzer after exposure to coloring food media. Safety assessment was carried out on samples made from teeth removed according to indications. Results. The results of laboratory tests allow us to conclude that the Chairside Light Whitening System professional teeth whitening system fläsh. (WHITEsmile GmbH, Germany) has high whitening efficiency with a whitening degree of ~84%, which significantly exceeds the norm of GOST R 702.3.004-2021. the microhardness of the enamel of samples exposed to the whitening gel for 15 minutes changes extremely little. After exposure of the studied samples to the Chairside Light Whitening System fläsh whitening system for 45 minutes, an increase in digital microhardness indicators is observed, which indicates the dynamics of processes demineralizing the hard tooth structure. Conclusions. Chairside Light Whitening System fläsh professional teeth whitening system has high whitening efficiency with minimal impact on the teeth structure and high safety.
- 19 February 2024
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 103 (1) , 16-22
Laboratory evaluation of the effectiveness and safety of the Chairside Light Whitening System fläsh
The aim of the study. Optimization of methods for treating dental discoloration using whitening systems based on hydrogen peroxide by laboratory studying their chemical properties. Material and methods. The effectiveness of the bleaching system was assessed by quantitatively assessing the color change of model samples of hydroxyapatite (HAP) in the CIE L*a*b* system on a Spectron-M color analyzer after exposure to coloring food media. Safety assessment was carried out on samples made from teeth removed according to indications. Results. The results of laboratory tests allow us to conclude that the Chairside Light Whitening System professional teeth whitening system fläsh. (WHITEsmile GmbH, Germany) has high whitening efficiency with a whitening degree of ~84%, which significantly exceeds the norm of GOST R 702.3.004-2021. the microhardness of the enamel of samples exposed to the whitening gel for 15 minutes changes extremely little. After exposure of the studied samples to the Chairside Light Whitening System fläsh whitening system for 45 minutes, an increase in digital microhardness indicators is observed, which indicates the dynamics of processes demineralizing the hard tooth structure. Conclusions. Chairside Light Whitening System fläsh professional teeth whitening system has high whitening efficiency with minimal impact on the teeth structure and high safety.
- Open Access
- 4 September 2022
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 26 (2) , 95-102
Effect of high-speed sintering modes of Russian zirconia samples made of Ziceram T on strength indicators and color
BACKGROUND: In recent years, zirconia prostheses have gradually become a mass type of orthopedic treatment. The production of zirconium dioxide blanks for dentistry has also been launched in our country. In recent years, the possibility of speed sintering of dental prostheses made of zirconia has been widely calculated, which makes it possible to reduce the process of manufacturing structures by four to five times. AIM: To investigate the effect of high-speed sintering on important properties, such as strength characteristics during three-point bending and color parameters at 10 different modes of speed sintering of ceramic materials. MATERIALS AND METHODS: The work uses samples obtained by computer-aided design and computer-aided manufacturing milling from domestic Ziceram T blanks, color A2. Depending on the firing modes, the samples were divided into 11 groups. The strength of the sintered samples was studied with three-point bending on a bursting machine. The color parameters of the samples were determined on the Spectron-M color analyzer in the CIE L*a*b system on a white and black background using acceptable norms of color difference and characteristics of color shades. RESULTS: According to the results of tests for resistance to bending, susceptibility has an approximate value of more than 300 MPa. According to ISO 6872, this flexural strength is sufficient for the fabrication чof single crowns in both anterior and posterior teeth. An increase in the lightness of ceramic samples based on zirconium dioxide from domestic factories Ziceram T of Zircon Ceramics was established. The reduced firing time led to an increase in body weight, which is associated with a decrease in their intensity. CONCLUSION: Express firing modes of ceramics based on zirconium dioxide Ziceram T guarantee the achievement of the required strength. However, none of the studied firing modes allowed achieving the color parameters of the control samples.
- 4 September 2022
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 26 (2) , 95-102
Open AccessEffect of high-speed sintering modes of Russian zirconia samples made of Ziceram T on strength indicators and color
BACKGROUND: In recent years, zirconia prostheses have gradually become a mass type of orthopedic treatment. The production of zirconium dioxide blanks for dentistry has also been launched in our country. In recent years, the possibility of speed sintering of dental prostheses made of zirconia has been widely calculated, which makes it possible to reduce the process of manufacturing structures by four to five times. AIM: To investigate the effect of high-speed sintering on important properties, such as strength characteristics during three-point bending and color parameters at 10 different modes of speed sintering of ceramic materials. MATERIALS AND METHODS: The work uses samples obtained by computer-aided design and computer-aided manufacturing milling from domestic Ziceram T blanks, color A2. Depending on the firing modes, the samples were divided into 11 groups. The strength of the sintered samples was studied with three-point bending on a bursting machine. The color parameters of the samples were determined on the Spectron-M color analyzer in the CIE L*a*b system on a white and black background using acceptable norms of color difference and characteristics of color shades. RESULTS: According to the results of tests for resistance to bending, susceptibility has an approximate value of more than 300 MPa. According to ISO 6872, this flexural strength is sufficient for the fabrication чof single crowns in both anterior and posterior teeth. An increase in the lightness of ceramic samples based on zirconium dioxide from domestic factories Ziceram T of Zircon Ceramics was established. The reduced firing time led to an increase in body weight, which is associated with a decrease in their intensity. CONCLUSION: Express firing modes of ceramics based on zirconium dioxide Ziceram T guarantee the achievement of the required strength. However, none of the studied firing modes allowed achieving the color parameters of the control samples.