Naruto Miyakawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Naruto Miyakawa has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shota Ushiba
Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan
4 shared publications - Takao Ono
Osaka Univ, SANKEN, Ibaraki, Osaka 5670047, Japan
4 shared publications - Yasushi Kanai
International Center for Synchrotron Radiation Innovation Smart, Tohoku University, 468-1 Aramaki Aza-Aoba, Aoba-ku, Sendai 980-8572, Japan
3 shared publications Ayumi Shinagawa
2 shared publicationsKazuhiko Matsumoto
2 shared publications- Kazuhiko Matsumoto
Osaka University
2 shared publications
Latest Publications
- 3 November 2023
- Published by Elsevier in Microchemical Journal
- Vol. 196
Semi-quantitative graphene chemiresistor enzyme immunoassay for simple and sensitive antigen detection
- 3 November 2023
- Published by Elsevier in Microchemical Journal
- Vol. 196
Semi-quantitative graphene chemiresistor enzyme immunoassay for simple and sensitive antigen detection
- Open Access
- 7 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Biosensing with Surface Charge Modulated Graphene Field-Effect Transistors Beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- 7 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessBiosensing with Surface Charge Modulated Graphene Field-Effect Transistors Beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- 14 October 2022
- Published by IOP Publishing in Applied Physics Express
- Vol. 15 (11) , 115002
Robust graphene field-effect transistor biosensors via hydrophobization of SiO2 substrates
The interfacial adhesion energy between graphene and underlying substrates is considerably important for robust graphene biosensors because water molecules can intercalate underneath graphene when submerged, possibly detaching graphene from substrates. This study investigated the robustness of graphene field-effect transistor arrays fabricated on hydrophobic and hydrophilic SiO2 substrates. Although the graphene sheets delaminated from hydrophilic substrates within minutes of submersion in a buffer solution, they remained stable on hydrophobic substrates for several days. This result agreed with the estimated thermodynamic work of adhesion in water, which improved significantly from −17.3 to 17.7 mJ m−2 through the hydrophobization process of the substrates.
- 14 October 2022
- Published by IOP Publishing in Applied Physics Express
- Vol. 15 (11) , 115002
Robust graphene field-effect transistor biosensors via hydrophobization of SiO2 substrates
The interfacial adhesion energy between graphene and underlying substrates is considerably important for robust graphene biosensors because water molecules can intercalate underneath graphene when submerged, possibly detaching graphene from substrates. This study investigated the robustness of graphene field-effect transistor arrays fabricated on hydrophobic and hydrophilic SiO2 substrates. Although the graphene sheets delaminated from hydrophilic substrates within minutes of submersion in a buffer solution, they remained stable on hydrophobic substrates for several days. This result agreed with the estimated thermodynamic work of adhesion in water, which improved significantly from −17.3 to 17.7 mJ m−2 through the hydrophobization process of the substrates.
- Open Access
Drift Suppression of Solution-Gated Graphene Field-Effect Transistors by Cation Doping for Sensing Platforms
Solution-gated graphene field-effect transistors (SG-GFETs) provide an ideal platform for sensing biomolecules owing to their high electron/hole mobilities and 2D nature. However, the transfer curve often drifts in an electrolyte solution during measurements, making it difficult to accurately estimate the analyte concentration. One possible reason for this drift is that p-doping of GFETs is gradually countered by cations in the solution, because the cations can permeate into the polymer residue and/or between graphene and SiO2 substrates. Therefore, we propose doping sufficient cations to counter p-doping of GFETs prior to the measurements. For the pre-treatment, GFETs were immersed in a 15 mM sodium chloride aqueous solution for 25 h. The pretreated GFETs showed that the charge neutrality point (CNP) drifted by less than 3 mV during 1 h of measurement in a phosphate buffer, while the non-treated GFETs showed that the CNP was severely drifted by approximately 50 mV, demonstrating a 96% reduction of the drift by the pre-treatment. X-ray photoelectron spectroscopy analysis revealed the accumulation of sodium ions in the GFETs through pre-treatment. Our method is useful for suppressing drift, thus allowing accurate estimation of the target analyte concentration.
Open AccessDrift Suppression of Solution-Gated Graphene Field-Effect Transistors by Cation Doping for Sensing Platforms
Solution-gated graphene field-effect transistors (SG-GFETs) provide an ideal platform for sensing biomolecules owing to their high electron/hole mobilities and 2D nature. However, the transfer curve often drifts in an electrolyte solution during measurements, making it difficult to accurately estimate the analyte concentration. One possible reason for this drift is that p-doping of GFETs is gradually countered by cations in the solution, because the cations can permeate into the polymer residue and/or between graphene and SiO2 substrates. Therefore, we propose doping sufficient cations to counter p-doping of GFETs prior to the measurements. For the pre-treatment, GFETs were immersed in a 15 mM sodium chloride aqueous solution for 25 h. The pretreated GFETs showed that the charge neutrality point (CNP) drifted by less than 3 mV during 1 h of measurement in a phosphate buffer, while the non-treated GFETs showed that the CNP was severely drifted by approximately 50 mV, demonstrating a 96% reduction of the drift by the pre-treatment. X-ray photoelectron spectroscopy analysis revealed the accumulation of sodium ions in the GFETs through pre-treatment. Our method is useful for suppressing drift, thus allowing accurate estimation of the target analyte concentration.