Hunter Stephens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hunter Stephens has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Q Jackie Wu
Duke University Medical Center
2 shared publications- Qiuwen Wu
Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
2 shared publications - Wentao Wang
Duke University Medical Center
2 shared publications - Xinyi Li
Radiation Oncology, Duke University, Department of Radiation Oncology Box 3085 Duke Cancer Center, Medicine Circle, Durham, Durham, North Carolina, 27710, UNITED STATES
2 shared publications Chunhao Wang
Duke University Medical Center
1 shared publication- Chunhao Wang
Department of Radiation Oncology Duke University Durham North Carolina USA
1 shared publication
Latest Publications
- 21 October 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (21) , 215009
Input feature design and its impact on the performance of deep learning models for predicting fluence maps in intensity-modulated radiation therapy
Objective . Deep learning (DL) models for fluence map prediction (FMP) have great potential to reduce treatment planning time in intensity-modulated radiation therapy (IMRT) by avoiding the lengthy inverse optimization process. This study aims to improve the rigor of input feature design in a DL-FMP model by examining how different designs of input features influence model prediction performance. Approach . This study included 231 head-and-neck intensity-modulated radiation therapy patients. Three input feature designs were investigated. The first design (D1) assumed that information of all critical structures from all beam angles should be combined to predict fluence maps. The second design (D2) assumed that local anatomical information was sufficient for predicting radiation intensity of a beamlet at a respective beam angle. The third design (D3) assumed the need for both local anatomical information and inter-beam modulation to predict radiation intensity values of the beamlets that intersect at a voxel. For each input design, we tailored the DL model accordingly. All models were trained using the same set of ground truth plans (GT plans). The plans generated by DL models (DL plans) were analyzed using key dose-volume metrics. One-way ANOVA with multiple comparisons correction (Bonferroni method) was performed (significance level = 0.05). Main results . For PTV-related metrics, all DL plans had significantly higher maximum dose ( p < 0.001), conformity index ( p < 0.001), and heterogeneity index ( p < 0.001) compared to GT plans, with D2 being the worst performer. Meanwhile, except for cord+5 mm ( p < 0.001), DL plans of all designs resulted in OAR dose metrics that are comparable to those of GT plans. Significance . Local anatomical information contains most of the information that DL models need to predict fluence maps for clinically acceptable OAR sparing. Input features from beam angles are needed to achieve the best PTV coverage. These results provide valuable insights for further improvement of DL-FMP models and DL models in general.
- 21 October 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (21) , 215009
Input feature design and its impact on the performance of deep learning models for predicting fluence maps in intensity-modulated radiation therapy
Objective . Deep learning (DL) models for fluence map prediction (FMP) have great potential to reduce treatment planning time in intensity-modulated radiation therapy (IMRT) by avoiding the lengthy inverse optimization process. This study aims to improve the rigor of input feature design in a DL-FMP model by examining how different designs of input features influence model prediction performance. Approach . This study included 231 head-and-neck intensity-modulated radiation therapy patients. Three input feature designs were investigated. The first design (D1) assumed that information of all critical structures from all beam angles should be combined to predict fluence maps. The second design (D2) assumed that local anatomical information was sufficient for predicting radiation intensity of a beamlet at a respective beam angle. The third design (D3) assumed the need for both local anatomical information and inter-beam modulation to predict radiation intensity values of the beamlets that intersect at a voxel. For each input design, we tailored the DL model accordingly. All models were trained using the same set of ground truth plans (GT plans). The plans generated by DL models (DL plans) were analyzed using key dose-volume metrics. One-way ANOVA with multiple comparisons correction (Bonferroni method) was performed (significance level = 0.05). Main results . For PTV-related metrics, all DL plans had significantly higher maximum dose ( p < 0.001), conformity index ( p < 0.001), and heterogeneity index ( p < 0.001) compared to GT plans, with D2 being the worst performer. Meanwhile, except for cord+5 mm ( p < 0.001), DL plans of all designs resulted in OAR dose metrics that are comparable to those of GT plans. Significance . Local anatomical information contains most of the information that DL models need to predict fluence maps for clinically acceptable OAR sparing. Input features from beam angles are needed to achieve the best PTV coverage. These results provide valuable insights for further improvement of DL-FMP models and DL models in general.
- 26 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (23) , 23NT01
Insights of an AI agent via analysis of prediction errors: a case study of fluence map prediction for radiation therapy planning
Purpose. We have previously reported an artificial intelligence (AI) agent that automatically generates intensity-modulated radiation therapy (IMRT) plans via fluence map prediction, by-passing inverse planning. This AI agent achieved clinically comparable quality for prostate cases, but its performance on head-and-neck patients leaves room for improvement. This study aims to collect insights of the deep-learning-based (DL-based) fluence map prediction model by systematically analyzing its prediction errors. Methods. From the modeling perspective, the DL model’s output is the fluence maps of IMRT plans. However, from the clinical planning perspective, the plan quality evaluation should be based on the clinical dosimetric criteria such as dose-volume histograms. To account for the complex and non-intuitive relationships between fluence map prediction errors and the corresponding dose distribution changes, we propose a novel error analysis approach that systematically examines plan dosimetric changes that are induced by varying amounts of fluence prediction errors. We investigated four decomposition modes of model prediction errors. The two spatial domain decompositions are based on fluence intensity and fluence gradient. The two frequency domain decompositions are based on Fourier-space banded frequency rings and Fourier-space truncated low-frequency disks. The decomposed error was analyzed for its impact on the resulting plans’ dosimetric metrics. The analysis was conducted on 15 test cases spared from the 200 training and 16 validation cases used to train the model. Results. Most planning target volume metrics were significantly correlated with most error decompositions. The Fourier space disk radii had the largest Spearman’s coefficients. The low-frequency region within a disk of ∼20% Fourier space contained most of errors that impact overall plan quality. Conclusions. This study demonstrates the feasibility of using fluence map prediction error analysis to understand the AI agent’s performance. Such insights will help fine-tune the DL models in architecture design and loss function selection.
- 26 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (23) , 23NT01
Insights of an AI agent via analysis of prediction errors: a case study of fluence map prediction for radiation therapy planning
Purpose. We have previously reported an artificial intelligence (AI) agent that automatically generates intensity-modulated radiation therapy (IMRT) plans via fluence map prediction, by-passing inverse planning. This AI agent achieved clinically comparable quality for prostate cases, but its performance on head-and-neck patients leaves room for improvement. This study aims to collect insights of the deep-learning-based (DL-based) fluence map prediction model by systematically analyzing its prediction errors. Methods. From the modeling perspective, the DL model’s output is the fluence maps of IMRT plans. However, from the clinical planning perspective, the plan quality evaluation should be based on the clinical dosimetric criteria such as dose-volume histograms. To account for the complex and non-intuitive relationships between fluence map prediction errors and the corresponding dose distribution changes, we propose a novel error analysis approach that systematically examines plan dosimetric changes that are induced by varying amounts of fluence prediction errors. We investigated four decomposition modes of model prediction errors. The two spatial domain decompositions are based on fluence intensity and fluence gradient. The two frequency domain decompositions are based on Fourier-space banded frequency rings and Fourier-space truncated low-frequency disks. The decomposed error was analyzed for its impact on the resulting plans’ dosimetric metrics. The analysis was conducted on 15 test cases spared from the 200 training and 16 validation cases used to train the model. Results. Most planning target volume metrics were significantly correlated with most error decompositions. The Fourier space disk radii had the largest Spearman’s coefficients. The low-frequency region within a disk of ∼20% Fourier space contained most of errors that impact overall plan quality. Conclusions. This study demonstrates the feasibility of using fluence map prediction error analysis to understand the AI agent’s performance. Such insights will help fine-tune the DL models in architecture design and loss function selection.
- 12 November 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 017001
Introducing matrix sparsity with kernel truncation into dose calculations for fluence optimization
Deep learning algorithms for radiation therapy treatment planning automation require large patient datasets and complex architectures that often take hundreds of hours to train. Some of these algorithms require constant dose updating (such as with reinforcement learning) and may take days. When these algorithms rely on commerical treatment planning systems to perform dose calculations, the data pipeline becomes the bottleneck of the entire algorithm’s efficiency. Further, uniformly accurate distributions are not always needed for the training and approximations can be introduced to speed up the process without affecting the outcome. These approximations not only speed up the calculation process, but allow for custom algorithms to be written specifically for the purposes of use in AI/ML applications where the dose and fluence must be calculated a multitude of times for a multitude of different situations. Here we present and investigate the effect of introducing matrix sparsity through kernel truncation on the dose calculation for the purposes of fluence optimzation within these AI/ML algorithms. The basis for this algorithm relies on voxel discrimination in which numerous voxels are pruned from the computationally expensive part of the calculation. This results in a significant reduction in computation time and storage. Comparing our dose calculation against calculations in both a water phantom and patient anatomy in Eclipse without heterogenity corrections produced gamma index passing rates around 99% for individual and composite beams with uniform fluence and around 98% for beams with a modulated fluence. The resulting sparsity introduces a reduction in computational time and space proportional to the square of the sparsity tolerance with a potential decrease in cost greater than 10 times that of a dense calculation allowing not only for faster caluclations but for calculations that a dense algorithm could not perform on the same system.
- 12 November 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 017001
Introducing matrix sparsity with kernel truncation into dose calculations for fluence optimization
Deep learning algorithms for radiation therapy treatment planning automation require large patient datasets and complex architectures that often take hundreds of hours to train. Some of these algorithms require constant dose updating (such as with reinforcement learning) and may take days. When these algorithms rely on commerical treatment planning systems to perform dose calculations, the data pipeline becomes the bottleneck of the entire algorithm’s efficiency. Further, uniformly accurate distributions are not always needed for the training and approximations can be introduced to speed up the process without affecting the outcome. These approximations not only speed up the calculation process, but allow for custom algorithms to be written specifically for the purposes of use in AI/ML applications where the dose and fluence must be calculated a multitude of times for a multitude of different situations. Here we present and investigate the effect of introducing matrix sparsity through kernel truncation on the dose calculation for the purposes of fluence optimzation within these AI/ML algorithms. The basis for this algorithm relies on voxel discrimination in which numerous voxels are pruned from the computationally expensive part of the calculation. This results in a significant reduction in computation time and storage. Comparing our dose calculation against calculations in both a water phantom and patient anatomy in Eclipse without heterogenity corrections produced gamma index passing rates around 99% for individual and composite beams with uniform fluence and around 98% for beams with a modulated fluence. The resulting sparsity introduces a reduction in computational time and space proportional to the square of the sparsity tolerance with a potential decrease in cost greater than 10 times that of a dense calculation allowing not only for faster caluclations but for calculations that a dense algorithm could not perform on the same system.