Hiroshi Oguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroshi Oguchi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Kuniyasu Okudaira
Nagoya University Hospital, Nagoya, Japan
2 shared publicationsEiji Kidoya
Radiological Center University of Fukui Hospital Fukui Japan
1 shared publication- Fujio Araki
Department of Health Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan
1 shared publication Fumitaka Kawabata
Department of Radiological Technology, Nagoya University Hospital, Nagoya, Aichi 466-8560, Japan
1 shared publication- Hirohiko Kimura
Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan
1 shared publication Hiroki Shioura
Department of Radiology University of Fukui Hospital Fukui Japan
1 shared publication
Latest Publications
- 6 August 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (4) , 291-297
Experimental determination of the effective point of measurement for cylindrical ionization chambers in megavoltage photon beams
Current dosimetry protocols specify an effective point of measurement (EPOM) shift of 0.6r for a cylindrical ionization chamber in photon beams. However, prior studies have reported that this shift was excessively large. The objective of this study was to experimentally evaluate the EPOM shifts in photon beams for cylindrical ionization chambers, which are widely used in clinical practice, and thus determine the appropriate EPOM shift. A microdiamond detector, which is a semiconductor detector with a small sensitive volume, was used as a reference detector, and the EPOM shifts of 11 types of cylindrical ionization chambers were evaluated at 6 MV and 10 MV. The depth shift from the percent depth dose (PDD) of the reference detector to that of the evaluated chamber was calculated using the least-squares method and was defined as the EPOM shift. The EPOM shift of the 10 MV condition was slightly larger than that of the 6 MV condition. However, because this trend was not observed for all chambers, the results of the two energies were averaged, and the EPOM shifts were determined to be 0.33r–0.43r (± 0.05) for 10 types of ionization chambers, and 0.03r (± 0.03) for the A1SL chamber. The shifts for all ionization chambers were smaller than 0.6r, indicating that the recommended EPOM shifts were overestimated and the absorbed dose was underestimated at the calibration depth. Hence, the appropriate EPOM shift of the 10 types of ionization chambers was 0.4r (the geometric center of the A1SL chamber), with a dose uncertainty of 0.05%.
- 6 August 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (4) , 291-297
Experimental determination of the effective point of measurement for cylindrical ionization chambers in megavoltage photon beams
Current dosimetry protocols specify an effective point of measurement (EPOM) shift of 0.6r for a cylindrical ionization chamber in photon beams. However, prior studies have reported that this shift was excessively large. The objective of this study was to experimentally evaluate the EPOM shifts in photon beams for cylindrical ionization chambers, which are widely used in clinical practice, and thus determine the appropriate EPOM shift. A microdiamond detector, which is a semiconductor detector with a small sensitive volume, was used as a reference detector, and the EPOM shifts of 11 types of cylindrical ionization chambers were evaluated at 6 MV and 10 MV. The depth shift from the percent depth dose (PDD) of the reference detector to that of the evaluated chamber was calculated using the least-squares method and was defined as the EPOM shift. The EPOM shift of the 10 MV condition was slightly larger than that of the 6 MV condition. However, because this trend was not observed for all chambers, the results of the two energies were averaged, and the EPOM shifts were determined to be 0.33r–0.43r (± 0.05) for 10 types of ionization chambers, and 0.03r (± 0.03) for the A1SL chamber. The shifts for all ionization chambers were smaller than 0.6r, indicating that the recommended EPOM shifts were overestimated and the absorbed dose was underestimated at the calibration depth. Hence, the appropriate EPOM shift of the 10 types of ionization chambers was 0.4r (the geometric center of the A1SL chamber), with a dose uncertainty of 0.05%.
- 1 November 2021
- Published by Elsevier in Physica Medica
- Vol. 91, 121-130
Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance
- 1 November 2021
- Published by Elsevier in Physica Medica
- Vol. 91, 121-130
Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance
- Open Access
- 3 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 306-312
Examining electrometer performance checks with direct‐current generator in a clinic: Assessment of generated charges and implementation of electrometer checks
Purpose: Medical physicists use a suitable detector connected to an electrometer to measure radiotherapy beams. Each detector and electrometer has a lifetime (due to physical deterioration of detector components and electrical characteristic deterioration in electronic electrometer components), long‐term stability [according to IEC 60731:2011, ≤0.5% (reference‐class dosimeter)], and calibration frequency [according to Muir et al. (J Appl Clin Med Phys. 2017; 18:182‐190), generally 2 years]; thus, physicists should check the electrometer and detector separately. However, to the best of our knowledge, only one study (Blad et al., Phys Med Biol. 1998; 43:2385–2391) has reported checking the electrometer independently from the detector. The present study conducts performance checks on electrometers separately from the detector in clinical settings, using an electrometer equipped with a direct current (DC) generator (EMF 521R) capable of injecting DC (effective range: ±20 pA to ±20 nA) into itself or another electrometer.Methods: First, to check the nonlinearity of the generated currents from ±20 pA to ±20 nA, charges generated from the DC generator were measured with the EMF 521R electrometer. Next, six reference‐class electrometers classified according to IEC 60731:2011 were checked for repeatability at a current of ±20 pA or a minimum effective indicated value meeting IEC 60731:2011, as well as for nonlinearity within the current range from ±20 pA to ±20 nA.Results: The nonlinearities for the measured currents were less than ±0.05%. The repeatability for the six electrometers was < 0.1%. While the nonlinearity of one electrometer reached up to 0.22% at a current of –20 pA, all six electrometers displayed nonlinearities of less than ±0.1% at currents of ±100 pA or higher.Conclusions: This work suggests that it is possible to check the nonlinearity and repeatability of clinical electrometers with DCs above the ±30 pA level using a DC generator in a clinic.
- 3 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 306-312
Open AccessExamining electrometer performance checks with direct‐current generator in a clinic: Assessment of generated charges and implementation of electrometer checks
Purpose: Medical physicists use a suitable detector connected to an electrometer to measure radiotherapy beams. Each detector and electrometer has a lifetime (due to physical deterioration of detector components and electrical characteristic deterioration in electronic electrometer components), long‐term stability [according to IEC 60731:2011, ≤0.5% (reference‐class dosimeter)], and calibration frequency [according to Muir et al. (J Appl Clin Med Phys. 2017; 18:182‐190), generally 2 years]; thus, physicists should check the electrometer and detector separately. However, to the best of our knowledge, only one study (Blad et al., Phys Med Biol. 1998; 43:2385–2391) has reported checking the electrometer independently from the detector. The present study conducts performance checks on electrometers separately from the detector in clinical settings, using an electrometer equipped with a direct current (DC) generator (EMF 521R) capable of injecting DC (effective range: ±20 pA to ±20 nA) into itself or another electrometer.Methods: First, to check the nonlinearity of the generated currents from ±20 pA to ±20 nA, charges generated from the DC generator were measured with the EMF 521R electrometer. Next, six reference‐class electrometers classified according to IEC 60731:2011 were checked for repeatability at a current of ±20 pA or a minimum effective indicated value meeting IEC 60731:2011, as well as for nonlinearity within the current range from ±20 pA to ±20 nA.Results: The nonlinearities for the measured currents were less than ±0.05%. The repeatability for the six electrometers was < 0.1%. While the nonlinearity of one electrometer reached up to 0.22% at a current of –20 pA, all six electrometers displayed nonlinearities of less than ±0.1% at currents of ±100 pA or higher.Conclusions: This work suggests that it is possible to check the nonlinearity and repeatability of clinical electrometers with DCs above the ±30 pA level using a DC generator in a clinic.
- 9 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 2992-3001
Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic‐therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water‐to‐plastic ionization conversion factor for PW and PWDT was computed for several commonly used Farmer‐type ionization chambers with different wall materials in the range of 4–18 MV photon beams. For electron beams, a depth‐scaling factor and a chamber‐dependent fluence correction factor for both phantoms were also calculated in combination with NACP‐02 and Roos plane‐parallel ionization chambers in the range of 4–18 MeV. The values for the plane‐parallel chambers were evaluated from the electron fluence correction factor and wall correction factors and for a combination of water or plastic materials. The calculated and values were verified by comparison with the measured values. A set of values computed for the Farmer‐type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The values also agreed within their combined uncertainty with the measured data. For electron beams, the values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4–18 MeV. The values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4–18 MeV. The difference in between water and plastic materials for the plane‐parallel chambers was 0.8% at a maximum. Finally, values evaluated for plastic materials were equal to unity within 0.6% for NACP‐02 and Roos chambers. The values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.
- 9 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 2992-3001
Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic‐therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water‐to‐plastic ionization conversion factor for PW and PWDT was computed for several commonly used Farmer‐type ionization chambers with different wall materials in the range of 4–18 MV photon beams. For electron beams, a depth‐scaling factor and a chamber‐dependent fluence correction factor for both phantoms were also calculated in combination with NACP‐02 and Roos plane‐parallel ionization chambers in the range of 4–18 MeV. The values for the plane‐parallel chambers were evaluated from the electron fluence correction factor and wall correction factors and for a combination of water or plastic materials. The calculated and values were verified by comparison with the measured values. A set of values computed for the Farmer‐type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The values also agreed within their combined uncertainty with the measured data. For electron beams, the values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4–18 MeV. The values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4–18 MeV. The difference in between water and plastic materials for the plane‐parallel chambers was 0.8% at a maximum. Finally, values evaluated for plastic materials were equal to unity within 0.6% for NACP‐02 and Roos chambers. The values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.