Caelen Matthew Clark
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Caelen Matthew Clark has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Mark T. Ehrensberger
Department of Biomedical Engineering, University at Buffalo, Buffalo, USA
2 shared publications Brandon M. Ruszala
Department of Biomedical Engineering, University at Buffalo, Buffalo, USA
1 shared publication- Brandon M. Ruszala
University of Rochester
1 shared publication Eric P. McDermott
Department of Biomedical Engineering, University at Buffalo, Buffalo, USA
1 shared publicationMark T. Ehrensberger
Department of Biomedical Engineering, University at Buffalo, Buffalo, USA
1 shared publication- Mary K. Canty
Garwood Medical Devices, LLC, Buffalo, New York, USA
1 shared publication
Latest Publications
- 30 January 2023
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 53 (6) , 1147-1156
Electrochemical generation of hydrogen peroxide during cathodic polarization of metallic orthopedic biomaterials
- 30 January 2023
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 53 (6) , 1147-1156
Electrochemical generation of hydrogen peroxide during cathodic polarization of metallic orthopedic biomaterials
- 19 October 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-02 (10) , 596
Characterizing the Impact of the Oxygen Reduction Reaction Mechanism and Current Distribution on Mineral Deposit Structure and Composition
- 19 October 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-02 (10) , 596
Characterizing the Impact of the Oxygen Reduction Reaction Mechanism and Current Distribution on Mineral Deposit Structure and Composition
- Open Access
- 13 March 2020
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 3 (5)
Development of durable microelectrodes for the detection of hydrogen peroxide and pH
Cathodic electrical stimulation has been investigated as a way to treat implant‐associated infection of orthopaedic devices. One of the proposed mechanisms of these effects is the changes in chemical gradients adjacent to the implant generated by the cathodic reaction products. Of these reaction products, both alkaline pH and hydrogen peroxide have been implicated as antimicrobial agents. However, direct measurement of these chemical effects has yet to be fully characterized for orthopaedic biomaterials. Microelectrodes are powerful tools that can be used to measure localized chemical conditions. Most commercially available sensors are fabricated from pulled glass pipettes, which make them quite fragile. In order to more easily make measurements of the effects of electrical stimulation, more durable sensors are desired. Solid‐state electrodes were fabricated from platinum and iridium micro‐wires to make H2O2 and pH‐sensitive electrodes, respectively. Additionally, a similar method was used to fabricate electrodes that were housed within a stainless steel needle, which could be used to penetrate and measure in solid samples without damaging the sensor. The H2O2 microelectrode was found to have a sensitivity of 34.1 pA/µM and a R2 value of .996. The pH microelectrode was found to have a linear calibration from 2 to 12 with a sensitivity of 76.7 mV/pH and a R2 of .996. The needle‐based electrodes were found to be able to detect changes in both H2O2 and pH when tested in an agar gel model.
- 13 March 2020
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 3 (5)
Open AccessDevelopment of durable microelectrodes for the detection of hydrogen peroxide and pH
Cathodic electrical stimulation has been investigated as a way to treat implant‐associated infection of orthopaedic devices. One of the proposed mechanisms of these effects is the changes in chemical gradients adjacent to the implant generated by the cathodic reaction products. Of these reaction products, both alkaline pH and hydrogen peroxide have been implicated as antimicrobial agents. However, direct measurement of these chemical effects has yet to be fully characterized for orthopaedic biomaterials. Microelectrodes are powerful tools that can be used to measure localized chemical conditions. Most commercially available sensors are fabricated from pulled glass pipettes, which make them quite fragile. In order to more easily make measurements of the effects of electrical stimulation, more durable sensors are desired. Solid‐state electrodes were fabricated from platinum and iridium micro‐wires to make H2O2 and pH‐sensitive electrodes, respectively. Additionally, a similar method was used to fabricate electrodes that were housed within a stainless steel needle, which could be used to penetrate and measure in solid samples without damaging the sensor. The H2O2 microelectrode was found to have a sensitivity of 34.1 pA/µM and a R2 value of .996. The pH microelectrode was found to have a linear calibration from 2 to 12 with a sensitivity of 76.7 mV/pH and a R2 of .996. The needle‐based electrodes were found to be able to detect changes in both H2O2 and pH when tested in an agar gel model.
- Open Access
- 19 November 2019
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 10 (1) , 17-41
Electrochemical methods to enhance osseointegrated prostheses
Osseointegrated (OI) prosthetic limbs have been shown to provide an advantageous treatment option for amputees. In order for the OI prosthesis to be successful, the titanium implant must rapidly achieve and maintain proper integration with the bone tissue and remain free of infection. Electrochemical methods can be utilized to control and/or monitor the interfacial microenvironment where the titanium implant interacts with the biological system (host bone tissue or bacteria). This review will summarize the current understanding of how electrochemical modalities can influence bone tissue and bacteria with specific emphasis on applications where the metallic prosthesis itself can be utilized directly as a stimulating electrode for enhanced osseointegration and infection control. In addition, a summary of electrochemical impedance sensing techniques that could be used to potentially assess osseointegration and infection status of the metallic prosthesis is presented.
- 19 November 2019
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 10 (1) , 17-41
Open AccessElectrochemical methods to enhance osseointegrated prostheses
Osseointegrated (OI) prosthetic limbs have been shown to provide an advantageous treatment option for amputees. In order for the OI prosthesis to be successful, the titanium implant must rapidly achieve and maintain proper integration with the bone tissue and remain free of infection. Electrochemical methods can be utilized to control and/or monitor the interfacial microenvironment where the titanium implant interacts with the biological system (host bone tissue or bacteria). This review will summarize the current understanding of how electrochemical modalities can influence bone tissue and bacteria with specific emphasis on applications where the metallic prosthesis itself can be utilized directly as a stimulating electrode for enhanced osseointegration and infection control. In addition, a summary of electrochemical impedance sensing techniques that could be used to potentially assess osseointegration and infection status of the metallic prosthesis is presented.