Brandon M. Ruszala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brandon M. Ruszala has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Marc H. Schieber
University of Rochester
3 shared publications - Kevin A. Mazurek
Department of Neuroscience, University of Rochester, Rochester, New York
2 shared publications - Caelen Matthew Clark
Department of Biomedical Engineering, University at Buffalo, Buffalo, USA
1 shared publication - Mark T. Ehrensberger
Department of Biomedical Engineering, University at Buffalo, Buffalo, USA
1 shared publication
Latest Publications
- Open Access
- 12 November 2026
- Published by IOP Publishing in Journal of Neural Engineering
Low-amplitude intracortical microstimulation produces short-latency modulation throughout the cortical reach-to-grasp network
Objective. Intracortical microstimulation (ICMS) can be used to deliver information to the cortex from a bidirectional brain-machine interface (BMI), thereby improving control of neuroprosthetic devices. Primary somatosensory cortex (S1) is a common choice for delivering information, but S1-ICMS can transsynaptically affect neurons in distant cortical regions such as primary motor cortex (M1), potentially disrupting BMI decoders trained on those neurons as inputs. Other nodes of the cortical reach-to-grasp network recently have been identified as effective territory for delivering information with ICMS. However, the extent of distant modulation produced by ICMS delivered in cortical regions other than S1 remains largely unknown. Approach. In each of two monkeys, we implanted several regions of the cortical reach-to-grasp network, including ventral premotor cortex, dorsal premotor cortex, M1, S1, the anterior intraparietal area, and dorsal posterior parietal cortex, and then delivered ICMS in each region (except M1) separately. We investigated whether the ICMS pulses in each region produced time-locked modulation of spike activity in neurons located in each of the other implanted regions. Results. ICMS pulses delivered in each region produced time-locked, short latency modulation of neurons recorded from most other implanted regions, including those not known to have direct anatomical interconnections with the stimulated region, with some effects having surprisingly high amplitudes and short latencies. Distant modulation effects were more common in frontal than in parietal regions, with neurons in M1 receiving particularly powerful modulation. Nevertheless, decoders trained on activity recorded from those M1 neurons during ICMS still could achieve strong performance. Significance. As the repertoire of cortical regions in which ICMS can be used to deliver information for bidirectional BMIs expands, knowledge about distant cortical modulation produced by ICMS will be useful to maintain robust decoding, as well as to better understand how information conveyed by ICMS is integrated into the cortical network.
- 12 November 2026
- Published by IOP Publishing in Journal of Neural Engineering
Open AccessLow-amplitude intracortical microstimulation produces short-latency modulation throughout the cortical reach-to-grasp network
Objective. Intracortical microstimulation (ICMS) can be used to deliver information to the cortex from a bidirectional brain-machine interface (BMI), thereby improving control of neuroprosthetic devices. Primary somatosensory cortex (S1) is a common choice for delivering information, but S1-ICMS can transsynaptically affect neurons in distant cortical regions such as primary motor cortex (M1), potentially disrupting BMI decoders trained on those neurons as inputs. Other nodes of the cortical reach-to-grasp network recently have been identified as effective territory for delivering information with ICMS. However, the extent of distant modulation produced by ICMS delivered in cortical regions other than S1 remains largely unknown. Approach. In each of two monkeys, we implanted several regions of the cortical reach-to-grasp network, including ventral premotor cortex, dorsal premotor cortex, M1, S1, the anterior intraparietal area, and dorsal posterior parietal cortex, and then delivered ICMS in each region (except M1) separately. We investigated whether the ICMS pulses in each region produced time-locked modulation of spike activity in neurons located in each of the other implanted regions. Results. ICMS pulses delivered in each region produced time-locked, short latency modulation of neurons recorded from most other implanted regions, including those not known to have direct anatomical interconnections with the stimulated region, with some effects having surprisingly high amplitudes and short latencies. Distant modulation effects were more common in frontal than in parietal regions, with neurons in M1 receiving particularly powerful modulation. Nevertheless, decoders trained on activity recorded from those M1 neurons during ICMS still could achieve strong performance. Significance. As the repertoire of cortical regions in which ICMS can be used to deliver information for bidirectional BMIs expands, knowledge about distant cortical modulation produced by ICMS will be useful to maintain robust decoding, as well as to better understand how information conveyed by ICMS is integrated into the cortical network.
- Open Access
- 1 October 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (5) , 056025
Disentangling indirect versus direct effects of somatosensory cortex microstimulation on neurons in primary motor and ventral premotor cortex
Objective. Intracortical microstimulation in the primary somatosensory cortex (S1-ICMS) is being developed to provide on-line feedback for bidirectional brain–machine interfaces. Because S1-ICMS can alter the discharge of the motor cortex neurons used to decode motor intent, successful application of S1-ICMS feedback requires understanding the modulation it produces in motor cortex neuron activity. Approach. We investigated the effects of S1-ICMS on neurons in both the primary motor cortex (M1) and the ventral premotor cortex (PMv) during a task in which some trials were instructed with visual cues and other trials with S1-ICMS. Main results. We observed both indirect modulation during and/or after ICMS trains, as well as direct modulation time-locked to the individual S1-ICMS pulses within trains, with all possible combinations of the two types of modulation found among the majority of M1 and PMv neurons. Indirect effects were more prevalent and larger than direct effects. When S1-ICMS produced both indirect and direct modulation in the same neuron, the effects could both be excitatory, both inhibitory, or one excitatory and the other inhibitory. By simulating direct effects, we isolated the concurrent indirect effects, revealing that isolated direct effects failed to account for isolated indirect effects. Furthermore, indirect effects could be present 1 s or more after ICMS trains had terminated, when no direct effects could have occurred. Although the performance of movement decoders trained on visually-instructed trials was poor when applied to ICMS-instructed trials, decoders trained on ICMS-instructed trials performed well on ICMS-instructed trials, indicating that S1-ICMS altered the discharge of M1 and PMv neurons but did not degrade the decodable information available. Significance. When decoding movement intent from neural activity in M1 and/or PMv, accounting for indirect and direct modulation may improve the ability of bidirectional brain–machine interfaces to incorporate artificial somatosensory feedback delivered with S1-ICMS and restore functional movement.
- 1 October 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (5) , 056025
Open AccessDisentangling indirect versus direct effects of somatosensory cortex microstimulation on neurons in primary motor and ventral premotor cortex
Objective. Intracortical microstimulation in the primary somatosensory cortex (S1-ICMS) is being developed to provide on-line feedback for bidirectional brain–machine interfaces. Because S1-ICMS can alter the discharge of the motor cortex neurons used to decode motor intent, successful application of S1-ICMS feedback requires understanding the modulation it produces in motor cortex neuron activity. Approach. We investigated the effects of S1-ICMS on neurons in both the primary motor cortex (M1) and the ventral premotor cortex (PMv) during a task in which some trials were instructed with visual cues and other trials with S1-ICMS. Main results. We observed both indirect modulation during and/or after ICMS trains, as well as direct modulation time-locked to the individual S1-ICMS pulses within trains, with all possible combinations of the two types of modulation found among the majority of M1 and PMv neurons. Indirect effects were more prevalent and larger than direct effects. When S1-ICMS produced both indirect and direct modulation in the same neuron, the effects could both be excitatory, both inhibitory, or one excitatory and the other inhibitory. By simulating direct effects, we isolated the concurrent indirect effects, revealing that isolated direct effects failed to account for isolated indirect effects. Furthermore, indirect effects could be present 1 s or more after ICMS trains had terminated, when no direct effects could have occurred. Although the performance of movement decoders trained on visually-instructed trials was poor when applied to ICMS-instructed trials, decoders trained on ICMS-instructed trials performed well on ICMS-instructed trials, indicating that S1-ICMS altered the discharge of M1 and PMv neurons but did not degrade the decodable information available. Significance. When decoding movement intent from neural activity in M1 and/or PMv, accounting for indirect and direct modulation may improve the ability of bidirectional brain–machine interfaces to incorporate artificial somatosensory feedback delivered with S1-ICMS and restore functional movement.
- Open Access
Somatosensory cortex microstimulation modulates primary motor and ventral premotor cortex neurons with extensive spatial convergence and divergence
Although intracortical microstimulation (ICMS) can affect distant neurons transynaptically, the extent to which ICMS pulses delivered in one cortical area actually modulate neurons in other cortical areas during voluntary behavior remains largely unknown. Here, we assessed how the individual pulses of multi-channel ICMS trains delivered in the primary somatosensory cortex (S1) modulate neuron firing in the primary motor (M1) and premotor (PM) cortex. S1-ICMS pulses modulated the majority of units recorded in both M1 and PM, producing more inhibition than excitation. Effects converged on individual neurons in both M1 and PM from extensive S1 territories. Conversely, effects of ICMS in a small region of S1 diverged to wide territories in both M1 and PM. Our findings may have ramifications for development of bidirectional brain-computer interfaces, where ICMS used to deliver artificial feedback in S1 could modulate the activity of neurons in M1 and PM, thereby hindering decoding of motor intent. Highlights Somatosensory cortex microstimulation modulated motor and premotor cortex neurons. Inhibitory effects were more common than excitatory effects. Effects from stimulation on each ∼2x2 mm multielectrode array diverged widely. Effects in individual neurons converged from multiple somatosensory arrays. eTOC blurb Ruszala and colleagues show that multi-channel intracortical microstimulation in a small patch of somatosensory cortex modulates neurons distributed widely in both the primary motor and premotor cortex, with more effects being inhibitory than excitatory. Such modulation may complicate decoding motor intent when artificial sensation is delivered in bidirectional brain-computer interfaces.
Open AccessSomatosensory cortex microstimulation modulates primary motor and ventral premotor cortex neurons with extensive spatial convergence and divergence
Although intracortical microstimulation (ICMS) can affect distant neurons transynaptically, the extent to which ICMS pulses delivered in one cortical area actually modulate neurons in other cortical areas during voluntary behavior remains largely unknown. Here, we assessed how the individual pulses of multi-channel ICMS trains delivered in the primary somatosensory cortex (S1) modulate neuron firing in the primary motor (M1) and premotor (PM) cortex. S1-ICMS pulses modulated the majority of units recorded in both M1 and PM, producing more inhibition than excitation. Effects converged on individual neurons in both M1 and PM from extensive S1 territories. Conversely, effects of ICMS in a small region of S1 diverged to wide territories in both M1 and PM. Our findings may have ramifications for development of bidirectional brain-computer interfaces, where ICMS used to deliver artificial feedback in S1 could modulate the activity of neurons in M1 and PM, thereby hindering decoding of motor intent. Highlights Somatosensory cortex microstimulation modulated motor and premotor cortex neurons. Inhibitory effects were more common than excitatory effects. Effects from stimulation on each ∼2x2 mm multielectrode array diverged widely. Effects in individual neurons converged from multiple somatosensory arrays. eTOC blurb Ruszala and colleagues show that multi-channel intracortical microstimulation in a small patch of somatosensory cortex modulates neurons distributed widely in both the primary motor and premotor cortex, with more effects being inhibitory than excitatory. Such modulation may complicate decoding motor intent when artificial sensation is delivered in bidirectional brain-computer interfaces.
- Open Access
- 13 March 2020
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 3 (5)
Development of durable microelectrodes for the detection of hydrogen peroxide and pH
Cathodic electrical stimulation has been investigated as a way to treat implant‐associated infection of orthopaedic devices. One of the proposed mechanisms of these effects is the changes in chemical gradients adjacent to the implant generated by the cathodic reaction products. Of these reaction products, both alkaline pH and hydrogen peroxide have been implicated as antimicrobial agents. However, direct measurement of these chemical effects has yet to be fully characterized for orthopaedic biomaterials. Microelectrodes are powerful tools that can be used to measure localized chemical conditions. Most commercially available sensors are fabricated from pulled glass pipettes, which make them quite fragile. In order to more easily make measurements of the effects of electrical stimulation, more durable sensors are desired. Solid‐state electrodes were fabricated from platinum and iridium micro‐wires to make H2O2 and pH‐sensitive electrodes, respectively. Additionally, a similar method was used to fabricate electrodes that were housed within a stainless steel needle, which could be used to penetrate and measure in solid samples without damaging the sensor. The H2O2 microelectrode was found to have a sensitivity of 34.1 pA/µM and a R2 value of .996. The pH microelectrode was found to have a linear calibration from 2 to 12 with a sensitivity of 76.7 mV/pH and a R2 of .996. The needle‐based electrodes were found to be able to detect changes in both H2O2 and pH when tested in an agar gel model.
- 13 March 2020
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 3 (5)
Open AccessDevelopment of durable microelectrodes for the detection of hydrogen peroxide and pH
Cathodic electrical stimulation has been investigated as a way to treat implant‐associated infection of orthopaedic devices. One of the proposed mechanisms of these effects is the changes in chemical gradients adjacent to the implant generated by the cathodic reaction products. Of these reaction products, both alkaline pH and hydrogen peroxide have been implicated as antimicrobial agents. However, direct measurement of these chemical effects has yet to be fully characterized for orthopaedic biomaterials. Microelectrodes are powerful tools that can be used to measure localized chemical conditions. Most commercially available sensors are fabricated from pulled glass pipettes, which make them quite fragile. In order to more easily make measurements of the effects of electrical stimulation, more durable sensors are desired. Solid‐state electrodes were fabricated from platinum and iridium micro‐wires to make H2O2 and pH‐sensitive electrodes, respectively. Additionally, a similar method was used to fabricate electrodes that were housed within a stainless steel needle, which could be used to penetrate and measure in solid samples without damaging the sensor. The H2O2 microelectrode was found to have a sensitivity of 34.1 pA/µM and a R2 value of .996. The pH microelectrode was found to have a linear calibration from 2 to 12 with a sensitivity of 76.7 mV/pH and a R2 of .996. The needle‐based electrodes were found to be able to detect changes in both H2O2 and pH when tested in an agar gel model.