Tessa E. Maurer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tessa E. Maurer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Sara A. Pozzi
University of Michigan
2 shared publications - Shaun D. Clarke
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
2 shared publications - Abbas Johar Jinia
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
1 shared publication - Christopher A. Meert
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
1 shared publication - David D. Wentzloff
University of Michigan
1 shared publication - E. A. Schneider
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
1 shared publication
Latest Publications
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3830-3834
Assessing Age Effects on Pulse Shape Discrimination Capabilities of Organic Glass Scintillators
Organic glass scintillators (OGS) are useful tools in nuclear engineering for their ability to detect both fast neutrons and gamma-rays. However, over time, this material can undergo recrystallization which can impact detection efficiency and pulse shape discrimination (PSD) capabilities. An understanding of such changes is necessary for long-term applications of these materials. The University of Michigan Scintillator Laboratory is equipped [1]with capabilities to melt-cast Sandia National Laboratories’ small-molecule organic glass scintillators. Fifteen 6.35 x 6.35 x 6.35 mm3 OGS cube scintillators were melt-cast from OGS powder. Half of these were exposed to 50 °C for 448 hours to induce surface crystallization through accelerated aging. PVA coatings were used to help slow this process in several of these scintillators. Using the same readout and electronic system of a DT5730S CAEN digitizer and a 7.62 cm diameter photomultiplier tube, we measured a Cf-252 source with each cube individually to evaluate their pulse shape discrimination (PSD) capabilities. These measurements showed less than a 6% decrease in light output across all samples following aging. PSD capabilities are not greatly impacted with an average percent change of figure of merit in the 0.25 to 0.75 MeVee energy range.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3830-3834
Assessing Age Effects on Pulse Shape Discrimination Capabilities of Organic Glass Scintillators
Organic glass scintillators (OGS) are useful tools in nuclear engineering for their ability to detect both fast neutrons and gamma-rays. However, over time, this material can undergo recrystallization which can impact detection efficiency and pulse shape discrimination (PSD) capabilities. An understanding of such changes is necessary for long-term applications of these materials. The University of Michigan Scintillator Laboratory is equipped [1]with capabilities to melt-cast Sandia National Laboratories’ small-molecule organic glass scintillators. Fifteen 6.35 x 6.35 x 6.35 mm3 OGS cube scintillators were melt-cast from OGS powder. Half of these were exposed to 50 °C for 448 hours to induce surface crystallization through accelerated aging. PVA coatings were used to help slow this process in several of these scintillators. Using the same readout and electronic system of a DT5730S CAEN digitizer and a 7.62 cm diameter photomultiplier tube, we measured a Cf-252 source with each cube individually to evaluate their pulse shape discrimination (PSD) capabilities. These measurements showed less than a 6% decrease in light output across all samples following aging. PSD capabilities are not greatly impacted with an average percent change of figure of merit in the 0.25 to 0.75 MeVee energy range.
- Open Access
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 119871-119880
An Artificial Neural Network System for Photon-Based Active Interrogation Applications
Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and trans-stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile-up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252 Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 27% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 62.32% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252 Cf fission source.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 119871-119880
Open AccessAn Artificial Neural Network System for Photon-Based Active Interrogation Applications
Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and trans-stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile-up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252 Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 27% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 62.32% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252 Cf fission source.