NQNang Vo Sy Quyen

Nang Vo Sy Quyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nang Vo Sy Quyen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Revision total hip arthroplasty for osteolysis and metallosis 17 years post-THA: a case report and literature review

    by Pham Trung Hieu, Luu Huu Phuc, Ta Tuan Anh, Le Duc Huy, Vo Sy Quyen Nang, Tran Trung Dung

    Introduction and importance: Pseudotumor formation and adverse reactions to metal debris are typically associated with metal-on-metal (MoM) total hip arthroplasty (THA) but are uncommon in metal-on-polyethylene (MoP) constructs. Catastrophic polyethylene liner wear leading to metallosis is rare and may present late. This case highlights severe wear-related failure occurring 17 years after primary THA. Case presentation: A 70-year-old man presented with progressive left hip pain and impaired mobility. Physical examination showed markedly restricted motion, and the Harris Hip Score was 35; he required crutches for ambulation. Radiographs revealed extensive osteolysis around the acetabular component and proximal femur, extending to the pubic ramus and femoral calcar. Cross-sectional imaging demonstrated a large pseudotumor with metal infiltration. Biopsy confirmed metallosis. Intraoperatively, complete polyethylene liner wear-through was identified, with direct MoM articulation between the femoral head and acetabular shell. The patient underwent revision THA using ceramic-on-ceramic bearing surfaces and cement augmentation. Clinical discussion: Although pseudotumor and metallosis are strongly linked to MoM bearings, advanced polyethylene wear can produce similar adverse local tissue reactions. Because symptoms may arise only after substantial structural compromise, late presentations remain a clinical risk. Long-term follow-up – particularly beyond 10–15 years – is crucial for detecting progressive wear, osteolysis, and soft-tissue changes before severe destruction occurs. This case illustrates the potential for catastrophic liner failure even in non-MoM constructs. Conclusion: Severe polyethylene wear in MoP THA can lead to metallosis and pseudotumor formation many years after implantation. Vigilant long-term surveillance is essential to ensure early recognition and timely revision to prevent extensive osteolysis and tissue damage.

  • Open Access

    3D-printed navicular replacement for giant cell tumor: a case report on a feasible indication and surgical outcome

    by Tran Quang Sang Nguyen, Nhat Anh Luong, Duc Huy Le, Sy Quyen Nang Vo, Trung Hieu Pham, Trung Dung Tran

    Introduction and importance: Giant cell tumor of the navicular is extremely rare and difficult to manage due to the complex biomechanics of the midfoot. Conventional curettage carries a high recurrence risk. This report presents a feasible approach using total navicular replacement for a giant cell tumor, offering a solution for achieving both oncologic control and functional reconstruction. Case presentation: A 32-year-old man presented with progressive midfoot pain and a Campanacci grade II giant cell tumor confined to the navicular. Imaging showed near-complete osteolysis with an intact cortex. A patient-specific titanium implant was designed using virtual surgical planning, incorporating porous surfaces and fixed screw trajectories for talocuneiform fusion. En bloc excision of the navicular and implantation of the custom device were performed through a medial approach. Postoperative recovery was uneventful. By 2 years, the patient was pain-free, exhibited a normal gait, and achieved excellent functional scores, with imaging confirming osseointegration and no recurrence. Clinical discussion: While three-dimension (3D print implants are increasingly used in complex foot and ankle reconstructions, their application for primary bone tumors in the midfoot has not been previously reported. This case demonstrates that custom implants can provide stable midfoot restoration when conventional grafting or curettage is insufficient. Advantages include precise anatomical matching and reliable fixation; however, cost and long-term durability remain considerations. Conclusion: Total navicular replacement using a custom 3D-printed implant achieved excellent 2-year oncologic and functional outcomes in this rare giant cell tumor case. This technique represents a viable and innovative reconstructive option for select midfoot tumors.

  • Open Access

    Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study

    by Tran Duc Thanh, Le Duc Huy, Nguyen Duc Trung, Luong Nhat Anh, Vu Duc Thang, Luu Huu Phuc, Le The Hung, Vo Sy Quyen Nang, Pham Trung Hieu, Nguyen Tran Quang Sang, et al.

    Background: Reconstruction of the proximal humerus after wide tumor resection is technically demanding, and traditional methods such as allograft–prosthetic composites, reverse shoulder arthroplasty, and metal implants are limited by graft unavailability, pediatric size mismatch, their high cost, and metal-related stress shielding. Polyether ether ketone (PEEK), with its modulus closer to cortical bone and radiolucency, offers a promising alternative. Building upon the success in craniomaxillofacial surgery and its favorable physical characteristics, we applied personalized 3D-printed PEEK implants for proximal humerus reconstruction. This study reports the first evidence of applying patient-specific 3D-printed PEEK implants in the proximal humerus. Methods: A retrospective cohort study was conducted on seven patients who underwent wide resection of primary malignant bone tumors of the proximal humerus, followed by reconstruction using patient-specific 3D-printed PEEK implants. Implant design was based on preoperative computed tomography (CT) imaging, incorporating contralateral humeral mirroring and computer-aided design. The implants were fabricated using fused deposition modeling (FDM) with medical-grade PEEK under stringent thermal control (nozzle temperature > 400 °C and heated build chamber), followed by a controlled annealing process to minimize internal stress, optimize polymer crystallinity, and enhance mechanical durability. Outcomes assessed included implant survival, oncologic control, shoulder range of motion, and functional outcomes measured using the Musculoskeletal Tumor Society (MSTS) score. The mean follow-up duration was 56.3 months. Results: All patient-specific PEEK implants were successfully manufactured and implanted with satisfactory geometric accuracy. Mechanical implant survival was 85.7% at final follow-up, with one implant fracture occurring at 28 months. No cases of deep infection, dislocation, loosening, or permanent neurovascular injury were observed. Local soft-tissue recurrence occurred in two patients (28.6%), without distant metastasis or tumor-related mortality. The limb-salvage rate was 100%. At final follow-up, the mean MSTS score was 23.0 ± 1.6. Shoulder motion was limited but comparable to outcomes reported for conventional anatomic megaprosthetic reconstructions. Conclusions: Patient-specific 3D-printed PEEK implants provide a feasible and oncologically safe option for proximal humerus reconstruction after tumor resection, with acceptable midterm implant survival and functional outcomes. The favorable elastic modulus and radiolucency of PEEK offer distinct biomechanical and imaging advantages over metallic implants. Further design optimization and larger prospective studies are warranted to enhance mechanical durability and functional restoration.


  • Open Access

    Suboptimal knee prosthesis design for Vietnamese women: a computed tomography-based arthrometric study

    by Tu Hoang Thanh Pham, Hieu Trung Pham, Nam Tu Vu, Hoang Viet Nguyen, Dung Trung Tran, Nang Vo Sy Quyen

    Background: Mismatches between knee dimensions and implant sizes can result in poor outcomes and dissatisfaction following total knee replacement. We aimed to evaluate knee morphology in Vietnamese women and assess the compatibility of available prostheses. Materials and methods: Using the full-leg CT scan datasets, we reconstructed 3D models of knee joints with software. After simulating femoral and tibial bone cuts with the mechanical alignment, the anteroposterior (AP) and mediolateral (ML) widths of the resection surfaces were measured. Six available prostheses were analyzed for their compatibility and coverage percent of the resected bone. Results: The study included 40 female patients with osteoarthritis (aged 51–79). AP and ML dimensions of distal femur were 63.07 ± 3.05 mm and 57.46 ± 3.06 mm; those of proximal tibia were 48.95 ± 3.01 mm and 67.14 ± 3.49 mm. Smaller knees exhibited higher femoral aspect ratio (ML/AP) compared to larger knees. Increasing the tibial AP resulted in a smaller ML length of the proximal tibia relative to the tibial component. With the AP and ML mismatch set at ± 1.5 and ± 3 mm, prosthesis system provided the best femoral component fit at only 67.5%. Tibial component coverage rates varied among implant systems, with the best fit prosthesis system covering 92.5% at a tolerance of ± 3 mm for both AP and ML dimensions. Conclusions: The current prosthetic options show significant mismatches with the knee morphology of Vietnamese women, highlighting the need for better suited implant designs. Further research is necessary to develop suitable prosthetic solutions. Keywords: knee dimensions total knee replacement Vietnamese anthropometry prosthesis coverage

  • Open Access

    Tenosynovial giant cell tumor of cruciate ligament

    by Nam Vu Tu, Nang Vo Sy Quyen, Minh Ho Ngoc, Hieu Pham Trung, Ba Son Nguyen, Dung Tran Trung

    Introduction: Tenosynovial giant cell tumor (TSGCT) is a slow-growing soft tissue tumor that develops from the synovial tissue of tendon sheaths, joints, or bursae. In the knee, this type of tumor is uncommon. Giant cell tumors of the cruciate ligaments' tendon sheath are far more infrequent. Only 16 localized TSGCTs of the cruciate ligaments have been recorded in the literature to our knowledge, with 9 involving the anterior cruciate ligament (ACL) and 7 involving the posterior cruciate ligament (PCL). Case presentation: We present a rare case of localized TSGCT arising from the PCL's femoral insertion in a 44-year-old male, as well as a literature review on localized TSGCT of cruciate ligaments in the knee. The diagnosis of tumor's presence was made using MRI while the definitive diagnosis was obtained through intraoperative evaluation and postoperative pathology. Conclusion: Arthroscopic tumor resection was an effective and safe treatment option based on the available data. Highlights:


  • Open Access

    Novel technique for scapulothoracic arthroscopy

    by Sy Quyen Nang Vo, Tu Nam Vu, Trung Hieu Pham, Huu Manh Nguyen, Trung Dung Tran

    Introduction: Snapping shoulder syndrome could be effectively treated with scapulothoracic arthroscopy. The excision of the scapular superomedial corner is assumed to help lower the recurrence rate. However, the amount of resection is still controversial. Furthermore, we lack a technique to measure if the resected amount was adequate based only on arthroscopy evaluation. Case study presentation: We describe a 47-year-old man who suffered from severe snapping shoulder syndrome as a consequence of a deformity of the left superomedial scapular corner. The patient had endoscopic bursectomy and superomedial corner resection. Intraoperative three-dimensional CT scans (3D-CT) were used to evaluate the amount of resection. The patient recovered without incident and resumed his usual activities within 30 days following surgery. At the six-month follow-up, there were no recurrent symptoms. Conclusion: Intraoperative 3D imaging significantly enhances the safety and efficacy of scapulothoracic arthroscopy. This is a novel technique that, to our knowledge, has not been reported previously in the literature. Highlights: