Sarah Badawi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarah Badawi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mehdi Narimani
Department of Electrical and Computer Engineering, McMaster University, Hamilton, Canada
7 shared publications - Navid Reza Zargari
Rockwell Automation Inc., Cambridge, ON, Canada
7 shared publications - Ahmed Abuelnaga
Rockwell Automation, Inc., Cambridge, ON, Canada
6 shared publications - Zhituo Ni
Rockwell Automation, Inc., Cambridge, ON, Canada
6 shared publications - Shaoyi Yuan
Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON, Canada
4 shared publications - Zhongyuan Cheng
Rockwell Automation Inc., Cambridge, ON, Canada
3 shared publications
Latest Publications
- Open Access
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 71361-71370
A New Approach to Reduce DC-Bus Capacitance in Regenerative CHB Motor Drives
The cascaded H-bridge (CHB) converters with diode-front-end (DFE) structure have been widely adopted in non-regenerative high-power medium-voltage motor drives. In order to allow regenerative capability, the diode-front end (DFE) in each power cell can be replaced by an IGBT-based active-front-end (AFE) operating as a PWM rectifier. Due to the inherent instantaneous power unbalance in the AFE-based CHB power cells, the DC-bus capacitance needs to be increased to reduce DC-bus voltage ripples. To reduce the DC-bus capacitance, control degrees of freedom provided by the PWM rectifiers can be exploited to mitigate the DC-bus voltage ripples. This paper proposes a new controller for regenerative CHB converters to perform DC-bus voltage control and ripple mitigation while maintaining high dynamic performance and canceling low order harmonics at the grid side to meet the grid standards. The effectiveness of the proposed control scheme is validated experimentally on a seven-level regenerative CHB drive.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 71361-71370
Open AccessA New Approach to Reduce DC-Bus Capacitance in Regenerative CHB Motor Drives
The cascaded H-bridge (CHB) converters with diode-front-end (DFE) structure have been widely adopted in non-regenerative high-power medium-voltage motor drives. In order to allow regenerative capability, the diode-front end (DFE) in each power cell can be replaced by an IGBT-based active-front-end (AFE) operating as a PWM rectifier. Due to the inherent instantaneous power unbalance in the AFE-based CHB power cells, the DC-bus capacitance needs to be increased to reduce DC-bus voltage ripples. To reduce the DC-bus capacitance, control degrees of freedom provided by the PWM rectifiers can be exploited to mitigate the DC-bus voltage ripples. This paper proposes a new controller for regenerative CHB converters to perform DC-bus voltage control and ripple mitigation while maintaining high dynamic performance and canceling low order harmonics at the grid side to meet the grid standards. The effectiveness of the proposed control scheme is validated experimentally on a seven-level regenerative CHB drive.
- 28 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 8559-8570
A New Active Front-End Control for Regenerative Cascaded H-Bridge Motor Drives With Filter- Less Interfacing Capability
This article proposes a new active-front-end (AFE) control method for regenerative cascaded H-bridge (CHB) motor drives. Conventional CHB converters have dominated the market for the medium-voltage industrial motor drives. However, conventional CHB converters cannot provide regenerative capability. To enable regeneration; diode-front-ends in power cells are replaced with insulated-gate bipolar transistor (IGBT)-based pulsewidth modulation (PWM) AFEs. Despite the appealing dynamic performance of PWM AFEs, their integration to the CHB converters is not optimal. First, they introduce more semiconductor losses due to the high-frequency switching. Second, they introduce switching harmonics that are not cancelled by phase-shifting transformers. Therefore, they require additional harmonic filtering solutions to comply with grid harmonic standards. To resolve these challenges, this article proposes a new AFE control for regenerative CHB converters based on fundamental frequency switching (FFE) to reduce switching frequency and thus power losses. The operation of FFEs at nominal and sag voltage conditions is presented, in addition to the capability of filter-less interfacing to the transformer. Finally, the performance of the proposed control is validated experimentally on a seven-level regenerative CHB drive.
- 28 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 8559-8570
A New Active Front-End Control for Regenerative Cascaded H-Bridge Motor Drives With Filter- Less Interfacing Capability
This article proposes a new active-front-end (AFE) control method for regenerative cascaded H-bridge (CHB) motor drives. Conventional CHB converters have dominated the market for the medium-voltage industrial motor drives. However, conventional CHB converters cannot provide regenerative capability. To enable regeneration; diode-front-ends in power cells are replaced with insulated-gate bipolar transistor (IGBT)-based pulsewidth modulation (PWM) AFEs. Despite the appealing dynamic performance of PWM AFEs, their integration to the CHB converters is not optimal. First, they introduce more semiconductor losses due to the high-frequency switching. Second, they introduce switching harmonics that are not cancelled by phase-shifting transformers. Therefore, they require additional harmonic filtering solutions to comply with grid harmonic standards. To resolve these challenges, this article proposes a new AFE control for regenerative CHB converters based on fundamental frequency switching (FFE) to reduce switching frequency and thus power losses. The operation of FFEs at nominal and sag voltage conditions is presented, in addition to the capability of filter-less interfacing to the transformer. Finally, the performance of the proposed control is validated experimentally on a seven-level regenerative CHB drive.
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (3) , 3352-3362
Control of Regenerative CHB Motor Drives at Fundamental Switching Frequency
To handle the high-power regeneration power in coal and mine industry applications, the regenerative version of the cascaded H-bridge (CHB) drives is made possible by replacing the diode-front-end rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, the IGBT switching devices introduce extra switching losses to the system that must be properly handled due to the thermal constraints in high power medium voltage drive applications. In this article, a novel fundamental switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive. With the proposed control strategy, the main harmonic contents generated by the AFEs are well-reshaped at a low-order harmonics range which can be further eliminated by the existing front-end phase-shifting transformer. This allows accomplishing the meeting of the IEEE std 519-2014 at the fundamental switching frequency f sw = 60. Moreover, with the proposed switching pattern, IGBTs can be turned off at zero current and therefore it can reduce switching losses simultaneously. The feasibility of the proposed control strategy is verified by experimental results on a seven-level regenerative CHB drive, which can be extended to regenerative CHB drives with any voltage levels.
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (3) , 3352-3362
Control of Regenerative CHB Motor Drives at Fundamental Switching Frequency
To handle the high-power regeneration power in coal and mine industry applications, the regenerative version of the cascaded H-bridge (CHB) drives is made possible by replacing the diode-front-end rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, the IGBT switching devices introduce extra switching losses to the system that must be properly handled due to the thermal constraints in high power medium voltage drive applications. In this article, a novel fundamental switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive. With the proposed control strategy, the main harmonic contents generated by the AFEs are well-reshaped at a low-order harmonics range which can be further eliminated by the existing front-end phase-shifting transformer. This allows accomplishing the meeting of the IEEE std 519-2014 at the fundamental switching frequency f sw = 60. Moreover, with the proposed switching pattern, IGBTs can be turned off at zero current and therefore it can reduce switching losses simultaneously. The feasibility of the proposed control strategy is verified by experimental results on a seven-level regenerative CHB drive, which can be extended to regenerative CHB drives with any voltage levels.
- 20 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (2) , 1973-1983
A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability
In conventional medium-voltage high-power cascaded H bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc bus voltage for the output H bridge. This limits the application of the conventional CHB drive where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low voltage sags in the power grid without triggering unnecessary downtime in transients. In this paper, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE std 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady-state. Moreover, low voltage ride-through capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.
- 20 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (2) , 1973-1983
A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability
In conventional medium-voltage high-power cascaded H bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc bus voltage for the output H bridge. This limits the application of the conventional CHB drive where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low voltage sags in the power grid without triggering unnecessary downtime in transients. In this paper, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE std 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady-state. Moreover, low voltage ride-through capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.
- Open Access
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 82944-82963
Review of Reduced Switch-Count Power Cells for Regenerative Cascaded H-Bridge Motor Drives
Cascaded H-Bridge (CHB) topology is one of the attractive topologies in high-power medium-voltage motor drive applications due to its modularity and scalability. Research in high power regenerative motor drives has gained significant attention with the increasing demand for efficient energy use. In a cascaded H-Bridge (CHB) converter, the regenerative capability can be introduced by replacing diode front end (DFE) with active front end (AFE) topologies. However, this results in a huge increase in the number of power semiconductors, gate drivers, and heat sink size and thus increases the overall size and cost of the regenerative CHB motor drives. To overcome the aforementioned challenges, different power cell designs have been introduced to reduce the switch count, allowing the design of more suitable-sized and more economical drives. This paper comprehensively reviews the reduced switch-count power cell designs, including single-phase and three-phase grid connections. Each reduced switch-count cell design is analyzed, and its advantages and disadvantages are studied in detail. The challenges that arise with each design and the method to address the challenges are discussed.
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 82944-82963
Open AccessReview of Reduced Switch-Count Power Cells for Regenerative Cascaded H-Bridge Motor Drives
Cascaded H-Bridge (CHB) topology is one of the attractive topologies in high-power medium-voltage motor drive applications due to its modularity and scalability. Research in high power regenerative motor drives has gained significant attention with the increasing demand for efficient energy use. In a cascaded H-Bridge (CHB) converter, the regenerative capability can be introduced by replacing diode front end (DFE) with active front end (AFE) topologies. However, this results in a huge increase in the number of power semiconductors, gate drivers, and heat sink size and thus increases the overall size and cost of the regenerative CHB motor drives. To overcome the aforementioned challenges, different power cell designs have been introduced to reduce the switch count, allowing the design of more suitable-sized and more economical drives. This paper comprehensively reviews the reduced switch-count power cell designs, including single-phase and three-phase grid connections. Each reduced switch-count cell design is analyzed, and its advantages and disadvantages are studied in detail. The challenges that arise with each design and the method to address the challenges are discussed.
- 17 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 6938-6949
Utilization of a Reduced Switch-Count Topology in Regenerative Cascaded H-Bridge (CHB) Medium-Voltage Drives
This paper employs a reduced switch-count topology in regenerative cascaded H-bridge (CHB) motor drives. Conventional regenerative CHB drive employs six-switch voltage source converters in the front end of each power cell to capture and utilize the regenerated energy. This solution is accompanied by high number of switches, gate drives, and control circuits, especially when the number of levels increases. This causes high switching power losses, and increase in the cost, size, and weight of the overall system. The paper utilizes a four-switch three-phase inverter active front end to reduce the switch-count of the CHB power cell. The utilization of the four-switch inverter creates several challenges in terms of voltage imbalance on the capacitors and harmonics on the grid side. First, these challenges in medium-voltage operation are analyzed and addressed. Then, a new phase alternation connection method and two carrier phase-shifting techniques are proposed in this paper to address the input current harmonics and comply with the grid connection standards. The performance of the proposed configuration and control techniques are analyzed theoretically and with simulation studies. The feasibility of the proposed configuration is validated experimentally on a scaled-down 7-level regenerative CHB drive.
- 17 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 6938-6949
Utilization of a Reduced Switch-Count Topology in Regenerative Cascaded H-Bridge (CHB) Medium-Voltage Drives
This paper employs a reduced switch-count topology in regenerative cascaded H-bridge (CHB) motor drives. Conventional regenerative CHB drive employs six-switch voltage source converters in the front end of each power cell to capture and utilize the regenerated energy. This solution is accompanied by high number of switches, gate drives, and control circuits, especially when the number of levels increases. This causes high switching power losses, and increase in the cost, size, and weight of the overall system. The paper utilizes a four-switch three-phase inverter active front end to reduce the switch-count of the CHB power cell. The utilization of the four-switch inverter creates several challenges in terms of voltage imbalance on the capacitors and harmonics on the grid side. First, these challenges in medium-voltage operation are analyzed and addressed. Then, a new phase alternation connection method and two carrier phase-shifting techniques are proposed in this paper to address the input current harmonics and comply with the grid connection standards. The performance of the proposed configuration and control techniques are analyzed theoretically and with simulation studies. The feasibility of the proposed configuration is validated experimentally on a scaled-down 7-level regenerative CHB drive.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (4) , 3266-3277
A New Approach to Input Filter Design for Regenerative Cascaded H-Bridge Drives
The diode-front-end (DFE) cascaded H-bridge (CHB) inverter has prevailed in the nonregenerative industry drive domain for high power medium voltage applications due to its modularity, scalability, and fault-tolerant capability. The regenerative version of the CHB drives is made possible by adding the extra active-front-end (AFE) rectifier in each power cell, such as a three-phase Pulse width modulation (PWM) rectifier. However, AFE introduces the switching harmonics which requires to be attenuated by designing a grid interfaced filter to comply with the harmonic standard IEEE 519-2014. High-order filters like LCL filters are not preferred due to complex inherent resonances in a multiparallel AFE system. A large number of capacitive components in the system rouse multiple resonances, which decreases system reliability and modularity. This article proposes an active filtering strategy based on the optimal asymmetric carrier-shifting method for regenerative CHB drives with only L filters. The required filter size is reduced significantly while complying with IEEE 519-2014 standard and thus improves the overall size, cost, and efficiency. The proposed filtering strategy is validated experimentally using a seven-level regenerative CHB drive.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (4) , 3266-3277
A New Approach to Input Filter Design for Regenerative Cascaded H-Bridge Drives
The diode-front-end (DFE) cascaded H-bridge (CHB) inverter has prevailed in the nonregenerative industry drive domain for high power medium voltage applications due to its modularity, scalability, and fault-tolerant capability. The regenerative version of the CHB drives is made possible by adding the extra active-front-end (AFE) rectifier in each power cell, such as a three-phase Pulse width modulation (PWM) rectifier. However, AFE introduces the switching harmonics which requires to be attenuated by designing a grid interfaced filter to comply with the harmonic standard IEEE 519-2014. High-order filters like LCL filters are not preferred due to complex inherent resonances in a multiparallel AFE system. A large number of capacitive components in the system rouse multiple resonances, which decreases system reliability and modularity. This article proposes an active filtering strategy based on the optimal asymmetric carrier-shifting method for regenerative CHB drives with only L filters. The required filter size is reduced significantly while complying with IEEE 519-2014 standard and thus improves the overall size, cost, and efficiency. The proposed filtering strategy is validated experimentally using a seven-level regenerative CHB drive.