Zhongyuan Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhongyuan Cheng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Abuelnaga
Rockwell Automation, Inc., Cambridge, ON, Canada
3 shared publications - Mehdi Narimani
Department of Electrical and Computer Engineering, McMaster University, Hamilton, Canada
3 shared publications - Navid Reza Zargari
Rockwell Automation Inc., Cambridge, ON, Canada
3 shared publications - Sarah Badawi
Electrical and Computer Engineering Department, McMaster University, Hamilton, Canada
3 shared publications - Shaoyi Yuan
Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON, Canada
3 shared publications - Zhituo Ni
Rockwell Automation, Inc., Cambridge, ON, Canada
3 shared publications
Latest Publications
- 20 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (2) , 1973-1983
A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability
In conventional medium-voltage high-power cascaded H bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc bus voltage for the output H bridge. This limits the application of the conventional CHB drive where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low voltage sags in the power grid without triggering unnecessary downtime in transients. In this paper, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE std 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady-state. Moreover, low voltage ride-through capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.
- 20 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (2) , 1973-1983
A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability
In conventional medium-voltage high-power cascaded H bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc bus voltage for the output H bridge. This limits the application of the conventional CHB drive where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low voltage sags in the power grid without triggering unnecessary downtime in transients. In this paper, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE std 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady-state. Moreover, low voltage ride-through capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.
- 17 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 6938-6949
Utilization of a Reduced Switch-Count Topology in Regenerative Cascaded H-Bridge (CHB) Medium-Voltage Drives
This paper employs a reduced switch-count topology in regenerative cascaded H-bridge (CHB) motor drives. Conventional regenerative CHB drive employs six-switch voltage source converters in the front end of each power cell to capture and utilize the regenerated energy. This solution is accompanied by high number of switches, gate drives, and control circuits, especially when the number of levels increases. This causes high switching power losses, and increase in the cost, size, and weight of the overall system. The paper utilizes a four-switch three-phase inverter active front end to reduce the switch-count of the CHB power cell. The utilization of the four-switch inverter creates several challenges in terms of voltage imbalance on the capacitors and harmonics on the grid side. First, these challenges in medium-voltage operation are analyzed and addressed. Then, a new phase alternation connection method and two carrier phase-shifting techniques are proposed in this paper to address the input current harmonics and comply with the grid connection standards. The performance of the proposed configuration and control techniques are analyzed theoretically and with simulation studies. The feasibility of the proposed configuration is validated experimentally on a scaled-down 7-level regenerative CHB drive.
- 17 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 6938-6949
Utilization of a Reduced Switch-Count Topology in Regenerative Cascaded H-Bridge (CHB) Medium-Voltage Drives
This paper employs a reduced switch-count topology in regenerative cascaded H-bridge (CHB) motor drives. Conventional regenerative CHB drive employs six-switch voltage source converters in the front end of each power cell to capture and utilize the regenerated energy. This solution is accompanied by high number of switches, gate drives, and control circuits, especially when the number of levels increases. This causes high switching power losses, and increase in the cost, size, and weight of the overall system. The paper utilizes a four-switch three-phase inverter active front end to reduce the switch-count of the CHB power cell. The utilization of the four-switch inverter creates several challenges in terms of voltage imbalance on the capacitors and harmonics on the grid side. First, these challenges in medium-voltage operation are analyzed and addressed. Then, a new phase alternation connection method and two carrier phase-shifting techniques are proposed in this paper to address the input current harmonics and comply with the grid connection standards. The performance of the proposed configuration and control techniques are analyzed theoretically and with simulation studies. The feasibility of the proposed configuration is validated experimentally on a scaled-down 7-level regenerative CHB drive.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (4) , 3266-3277
A New Approach to Input Filter Design for Regenerative Cascaded H-Bridge Drives
The diode-front-end (DFE) cascaded H-bridge (CHB) inverter has prevailed in the nonregenerative industry drive domain for high power medium voltage applications due to its modularity, scalability, and fault-tolerant capability. The regenerative version of the CHB drives is made possible by adding the extra active-front-end (AFE) rectifier in each power cell, such as a three-phase Pulse width modulation (PWM) rectifier. However, AFE introduces the switching harmonics which requires to be attenuated by designing a grid interfaced filter to comply with the harmonic standard IEEE 519-2014. High-order filters like LCL filters are not preferred due to complex inherent resonances in a multiparallel AFE system. A large number of capacitive components in the system rouse multiple resonances, which decreases system reliability and modularity. This article proposes an active filtering strategy based on the optimal asymmetric carrier-shifting method for regenerative CHB drives with only L filters. The required filter size is reduced significantly while complying with IEEE 519-2014 standard and thus improves the overall size, cost, and efficiency. The proposed filtering strategy is validated experimentally using a seven-level regenerative CHB drive.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (4) , 3266-3277
A New Approach to Input Filter Design for Regenerative Cascaded H-Bridge Drives
The diode-front-end (DFE) cascaded H-bridge (CHB) inverter has prevailed in the nonregenerative industry drive domain for high power medium voltage applications due to its modularity, scalability, and fault-tolerant capability. The regenerative version of the CHB drives is made possible by adding the extra active-front-end (AFE) rectifier in each power cell, such as a three-phase Pulse width modulation (PWM) rectifier. However, AFE introduces the switching harmonics which requires to be attenuated by designing a grid interfaced filter to comply with the harmonic standard IEEE 519-2014. High-order filters like LCL filters are not preferred due to complex inherent resonances in a multiparallel AFE system. A large number of capacitive components in the system rouse multiple resonances, which decreases system reliability and modularity. This article proposes an active filtering strategy based on the optimal asymmetric carrier-shifting method for regenerative CHB drives with only L filters. The required filter size is reduced significantly while complying with IEEE 519-2014 standard and thus improves the overall size, cost, and efficiency. The proposed filtering strategy is validated experimentally using a seven-level regenerative CHB drive.