Stefania Gravina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefania Gravina has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Castrillo
Università degli Studi della Campania “Luigi Vanvitelli
11 shared publications - Livio Gianfrani
Università degli Studi della Campania “Luigi Vanvitelli
11 shared publications - Eugenio Fasci
Sezione INFN di Napoli
7 shared publications - Vittorio D'AGostino
Università degli Studi della Campania Luigi Vanvitelli
4 shared publications - Naveed Ahmed Chishti
Università degli Studi della Campania “Luigi Vanvitelli
3 shared publications - Cecilia Clivati
Istituto Nazionale di Ricerca Metrologica (INRiM)
2 shared publications
Latest Publications
- Open Access
Primary Humidity Standards for Trace Water Measurements in Ultra-High-Purity Process Gases
Trace water is one of the most critical matrix contaminants in ultra-high-purity (UHP) process gases, like argon (Ar), nitrogen (N2), and many others. Even trace amounts can severely degrade the quality of many products that are reliant on these gases. Despite its importance to advanced technology sectors, notably semiconductor manufacturing, it has proven quite difficult to realize preparative or analytical trace water metrology over the full amount fraction range needed or in the broad spectrum of industrially relevant matrix gases. Within the EU-funded PROMETH2O project consortium, this challenge has been addressed through the development or significant improvement of traceable measurement methods and standards spanning 5 nmol⋅mol−1 to 5 µmol⋅mol−1, tailored for use in UHP process gas production, such as Ar, N2 and clean dry air (CDA). The measurement ranges were extended and the uncertainties were improved while being consistent with the current best practice at primary humidity standard laboratories. The developed standards provide combined standard uncertainties ranging from approximately 0.4 % to 1.5 % in water vapor amount fraction and from 0.03 °C to 0.07 °C in frost-point temperature, while the comb-assisted CRDS system achieves detection limits in the sub-ppb to ppt range. These capabilities were validated in applications that are relevant to process instrumentation and the gas industry. A distributed metrological infrastructure at various European national metrology institutes and partner sites now provides SI-traceable trace water measurements in UHP gases, strongly supporting and extending the calibration capabilities for the gas and semiconductor industries and the associated stakeholders.
Open AccessPrimary Humidity Standards for Trace Water Measurements in Ultra-High-Purity Process Gases
Trace water is one of the most critical matrix contaminants in ultra-high-purity (UHP) process gases, like argon (Ar), nitrogen (N2), and many others. Even trace amounts can severely degrade the quality of many products that are reliant on these gases. Despite its importance to advanced technology sectors, notably semiconductor manufacturing, it has proven quite difficult to realize preparative or analytical trace water metrology over the full amount fraction range needed or in the broad spectrum of industrially relevant matrix gases. Within the EU-funded PROMETH2O project consortium, this challenge has been addressed through the development or significant improvement of traceable measurement methods and standards spanning 5 nmol⋅mol−1 to 5 µmol⋅mol−1, tailored for use in UHP process gas production, such as Ar, N2 and clean dry air (CDA). The measurement ranges were extended and the uncertainties were improved while being consistent with the current best practice at primary humidity standard laboratories. The developed standards provide combined standard uncertainties ranging from approximately 0.4 % to 1.5 % in water vapor amount fraction and from 0.03 °C to 0.07 °C in frost-point temperature, while the comb-assisted CRDS system achieves detection limits in the sub-ppb to ppt range. These capabilities were validated in applications that are relevant to process instrumentation and the gas industry. A distributed metrological infrastructure at various European national metrology institutes and partner sites now provides SI-traceable trace water measurements in UHP gases, strongly supporting and extending the calibration capabilities for the gas and semiconductor industries and the associated stakeholders.
- Open Access
- 30 April 2026
- Published by MDPI AG in Preprints.org
Primary Trace Humidity Standards and SI-Traceable Trace Water Measurements in Ultra-High Purity Process Gases
Trace water is one of the most critical matrix contaminants in ultra-high purity (UHP) process gases, like argon (Ar) and nitrogen (N₂), and many others. Even trace amounts can severely degrade the quality of many products reliant on these gases. Despite its importance to advanced technology sectors, notably semiconductor manufacturing, it has proven quite difficult to realize preparative or analytical trace water metrology over the full amount fraction range needed or in the broad spectrum of industrially relevant matrix gases. Within the EU-funded PROMETH2O project consortium, this challenge has been addressed through the development or significant improvement of traceable measurement methods and standards spanning 5 nmol mol⁻¹ to 5 µmol mol⁻¹, tailored for use in UHP process gas production, such as Ar, N2 and hydrogen (H2). The measurement ranges were extended and the uncertainties were improved, while being consistent with current best practice at primary humidity standards laboratories. These capabilities were validated in applications relevant to process instrumentation and the gas industry. A distributed metrological infrastructure at various European National Metrology Institutes and partner sites now provides SI-traceable trace water measurements in various UHP, strongly supporting and extending the calibration capabilities for the gas and semiconductor industries and the associated stakeholders.
- 30 April 2026
- Published by MDPI AG in Preprints.org
Open AccessPrimary Trace Humidity Standards and SI-Traceable Trace Water Measurements in Ultra-High Purity Process Gases
Trace water is one of the most critical matrix contaminants in ultra-high purity (UHP) process gases, like argon (Ar) and nitrogen (N₂), and many others. Even trace amounts can severely degrade the quality of many products reliant on these gases. Despite its importance to advanced technology sectors, notably semiconductor manufacturing, it has proven quite difficult to realize preparative or analytical trace water metrology over the full amount fraction range needed or in the broad spectrum of industrially relevant matrix gases. Within the EU-funded PROMETH2O project consortium, this challenge has been addressed through the development or significant improvement of traceable measurement methods and standards spanning 5 nmol mol⁻¹ to 5 µmol mol⁻¹, tailored for use in UHP process gas production, such as Ar, N2 and hydrogen (H2). The measurement ranges were extended and the uncertainties were improved, while being consistent with current best practice at primary humidity standards laboratories. These capabilities were validated in applications relevant to process instrumentation and the gas industry. A distributed metrological infrastructure at various European National Metrology Institutes and partner sites now provides SI-traceable trace water measurements in various UHP, strongly supporting and extending the calibration capabilities for the gas and semiconductor industries and the associated stakeholders.
- 24 February 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (5) , 7525-7537
Linear optical-feedback cavity ring-down spectroscopy using an interband cascade laser at 3- µ m wavelength
We report on a linear optical-feedback cavity ring-down spectrometer (LOF-CRDS) operating under ultra-high vacuum (UHV) conditions, designed for high-sensitivity detection of light hydrocarbons. The system employs an interband cascade laser (ICL) operating at 3 µ m, in coincidence with the strong absorption features of the asymmetric C-H stretching vibrational mode. Taking advantage of the passive optical feedback from the high-finesse linear cavity, the ICL emission linewidth is drastically narrowed, thus facilitating light coupling into the cavity. An empty-cavity ring-down time of about 18 µ s was measured, which translates into a cavity finesse of ∼37000 and a cavity-mode width of ∼9 kHz. As a result of an Allan-Werle analysis, performed at a fixed ICL frequency, we determined a minimum detectable absorption coefficient of ∼2.5×10 −10 cm −1 for an integration time of approximately 100 s. The spectrometer was tested on the R(25) component of the acetylene ν 3 vibrational band at 3352.2874 cm −1 . In this regard, we report on spectroscopic measurements of the C 2 H 2 partial pressure in the UHV chamber. For the selected line, the sensitivity leads to a limit of detection of 2.1×10 −8 mbar.
- 24 February 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (5) , 7525-7537
Linear optical-feedback cavity ring-down spectroscopy using an interband cascade laser at 3- µ m wavelength
We report on a linear optical-feedback cavity ring-down spectrometer (LOF-CRDS) operating under ultra-high vacuum (UHV) conditions, designed for high-sensitivity detection of light hydrocarbons. The system employs an interband cascade laser (ICL) operating at 3 µ m, in coincidence with the strong absorption features of the asymmetric C-H stretching vibrational mode. Taking advantage of the passive optical feedback from the high-finesse linear cavity, the ICL emission linewidth is drastically narrowed, thus facilitating light coupling into the cavity. An empty-cavity ring-down time of about 18 µ s was measured, which translates into a cavity finesse of ∼37000 and a cavity-mode width of ∼9 kHz. As a result of an Allan-Werle analysis, performed at a fixed ICL frequency, we determined a minimum detectable absorption coefficient of ∼2.5×10 −10 cm −1 for an integration time of approximately 100 s. The spectrometer was tested on the R(25) component of the acetylene ν 3 vibrational band at 3352.2874 cm −1 . In this regard, we report on spectroscopic measurements of the C 2 H 2 partial pressure in the UHV chamber. For the selected line, the sensitivity leads to a limit of detection of 2.1×10 −8 mbar.
- 9 February 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (6) , 063001
Isotope Shift Spectroscopy in Mercury Vapors: A Promising Alternative to Ytterbium for New Physics Search
Isotope shift metrology in the deep-UV region has been performed for all bosonic isotopes of mercury with a zero nuclear spin, using the technique of frequency-comb referenced, wavelength-modulated, saturated absorption spectroscopy. The absolute center frequencies of the 6s^{2} ^{1}S_{0}→6s6p ^{3}P_{1} transition have been measured with precision in the range of 2.5-5.9 10^{-12} in temperature-stabilized Hg vapor samples with natural abundances. Frequency shifts in four isotope pairs have been determined with unprecedented accuracy, the global uncertainty being improved by a factor greater than 20 with respect to the best experimental data of the past literature. Our dataset, when combined with previous measurements on the 6s6p ^{3}P_{2}→6s7s ^{3}S_{1} transition at 546 nm, allows us to build a King plot that reveals a nonlinearity with a statistical significance of 4.6σ.
- 9 February 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (6) , 063001
Isotope Shift Spectroscopy in Mercury Vapors: A Promising Alternative to Ytterbium for New Physics Search
Isotope shift metrology in the deep-UV region has been performed for all bosonic isotopes of mercury with a zero nuclear spin, using the technique of frequency-comb referenced, wavelength-modulated, saturated absorption spectroscopy. The absolute center frequencies of the 6s^{2} ^{1}S_{0}→6s6p ^{3}P_{1} transition have been measured with precision in the range of 2.5-5.9 10^{-12} in temperature-stabilized Hg vapor samples with natural abundances. Frequency shifts in four isotope pairs have been determined with unprecedented accuracy, the global uncertainty being improved by a factor greater than 20 with respect to the best experimental data of the past literature. Our dataset, when combined with previous measurements on the 6s6p ^{3}P_{2}→6s7s ^{3}S_{1} transition at 546 nm, allows us to build a King plot that reveals a nonlinearity with a statistical significance of 4.6σ.
- 12 June 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (12) , 4078-4081
Cavity ring-down spectroscopy at 2-μm wavelength assisted by a comb-locked optical parametric oscillator
We report on a comb-locked cavity ring-down spectrometer developed for high-precision molecular spectroscopy at 2 μm. It is based on the use of an external-cavity diode laser that is offset-frequency locked to the signal output of a singly-resonant optical parametric oscillator. This latter acts as a reference laser, being locked to a self-referenced optical frequency comb, which in turn is stabilized against a GPS-disciplined Rb-clock. The performance of the spectrometer is investigated by probing a pair of N2O transitions belonging to hot vibrational bands. One of these has never, to the best of our knowledge, been observed before, and is included in the N2O line list of the ExoMol database. Absolute center frequencies are retrieved with a 1-σ global uncertainty of 108 kHz.
- 12 June 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (12) , 4078-4081
Cavity ring-down spectroscopy at 2-μm wavelength assisted by a comb-locked optical parametric oscillator
We report on a comb-locked cavity ring-down spectrometer developed for high-precision molecular spectroscopy at 2 μm. It is based on the use of an external-cavity diode laser that is offset-frequency locked to the signal output of a singly-resonant optical parametric oscillator. This latter acts as a reference laser, being locked to a self-referenced optical frequency comb, which in turn is stabilized against a GPS-disciplined Rb-clock. The performance of the spectrometer is investigated by probing a pair of N2O transitions belonging to hot vibrational bands. One of these has never, to the best of our knowledge, been observed before, and is included in the N2O line list of the ExoMol database. Absolute center frequencies are retrieved with a 1-σ global uncertainty of 108 kHz.
- 9 September 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (9) , 1277-1284
Demonstration of record sensitivity for water vapor detection by means of comb-locked cavity ring-down spectroscopy
We report on the development, characterization, and test of a comb-locked cavity ring-down spectrometer (CL-CRDS) operating in the spectral region around 1.39 µm. The system is based on the use of a hemispherical optical resonator with a finesse as high as ∼507000, which gives an empty-cavity ring-down time of about 285 µs. An Allan-Werle analysis on repeated acquisitions of the ring-down time at a fixed laser frequency suggests a minimum detectable absorption coefficient of 2×10−12cm−1 for the optimum integration time of 45 s. This limit can be exceeded by adopting the strategy of long-term spectral averaging. Taking advantage of the frequency stability guaranteed by the optical frequency comb, the CL-CRDS spectra were averaged over more than two days, thus removing efficiently the effect of mechanical, acoustic, and thermal noises. As a result, we could achieve a minimum detectable absorption coefficient as low as 3.7×10−13cm−1, which corresponds to a limit of detection for H2O in N2 of nine parts per trillion and a H2O partial pressure of 2×10−8 Pa (or 2×10−10 mbar). The potentialities of our approach are demonstrated by recording the absorption features of HD16O and HD18O in flows of ultra-high-purity N2 and ambient air, respectively.
- 9 September 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (9) , 1277-1284
Demonstration of record sensitivity for water vapor detection by means of comb-locked cavity ring-down spectroscopy
We report on the development, characterization, and test of a comb-locked cavity ring-down spectrometer (CL-CRDS) operating in the spectral region around 1.39 µm. The system is based on the use of a hemispherical optical resonator with a finesse as high as ∼507000, which gives an empty-cavity ring-down time of about 285 µs. An Allan-Werle analysis on repeated acquisitions of the ring-down time at a fixed laser frequency suggests a minimum detectable absorption coefficient of 2×10−12cm−1 for the optimum integration time of 45 s. This limit can be exceeded by adopting the strategy of long-term spectral averaging. Taking advantage of the frequency stability guaranteed by the optical frequency comb, the CL-CRDS spectra were averaged over more than two days, thus removing efficiently the effect of mechanical, acoustic, and thermal noises. As a result, we could achieve a minimum detectable absorption coefficient as low as 3.7×10−13cm−1, which corresponds to a limit of detection for H2O in N2 of nine parts per trillion and a H2O partial pressure of 2×10−8 Pa (or 2×10−10 mbar). The potentialities of our approach are demonstrated by recording the absorption features of HD16O and HD18O in flows of ultra-high-purity N2 and ambient air, respectively.
- 24 May 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (21) , 213001
Comb-Referenced Doppler-Free Spectrometry of the and Intercombination Line at 254 nmWe report on precision spectroscopy of the intercombination line of mercury in the deep ultraviolet, by means of a frequency-comb referenced, wavelength-modulated, saturated absorption technique. This method allowed us to perform sub-Doppler investigations with an absolute frequency axis at 254 nm, while ensuring a relatively high signal-to-noise ratio. The absolute line center frequencies of the and bosonic isotopes were measured with a global uncertainty of 8 and 15 kHz (namely, and , in relative terms), respectively, the statistical and systematic components being significantly reduced as compared to past determinations. This remarkable result was achieved also thanks to an in-depth study of the ac Stark effect. Furthermore, we found the most accurate isotope shift ever obtained before, namely, .- 24 May 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (21) , 213001
Comb-Referenced Doppler-Free Spectrometry of the and Intercombination Line at 254 nmWe report on precision spectroscopy of the intercombination line of mercury in the deep ultraviolet, by means of a frequency-comb referenced, wavelength-modulated, saturated absorption technique. This method allowed us to perform sub-Doppler investigations with an absolute frequency axis at 254 nm, while ensuring a relatively high signal-to-noise ratio. The absolute line center frequencies of the and bosonic isotopes were measured with a global uncertainty of 8 and 15 kHz (namely, and , in relative terms), respectively, the statistical and systematic components being significantly reduced as compared to past determinations. This remarkable result was achieved also thanks to an in-depth study of the ac Stark effect. Furthermore, we found the most accurate isotope shift ever obtained before, namely, .- 26 February 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (2) , 022816
Comb-locked deep-ultraviolet laser system for precision mercury spectroscopy
Doppler-broadening gas thermometry is extended to the deep-ultraviolet domain using a comb-locked laser frequency chain, expressly developed for precision spectroscopy of mercury vapors at the wavelength of 253.7 nm, in coincidence with the intercombination line. The system is based on a double-stage second-harmonic generation process of an external-cavity diode laser at 1014.8 nm, which is frequency locked to a self-referenced optical-frequency-comb synthesizer by means of an efficient nonlinear frequency-mixing scheme. An absolute frequency axis in the UV region is produced by scanning the comb repetition rate, with the entire frequency chain following the reference comb tooth. The complete characterization of the phase noise of the comb-locked near-infrared laser demonstrates line-emission narrowing down to the limit imposed by the coherence of the comb teeth. After a proper processing of the phase noise, the Gaussian and Lorentzian components of the width of the UV radiation are determined. This is useful to estimate the instrumental perturbation to the probed mercury line for the aims of thermodynamic temperature metrology. In this regard, the preliminary spectroscopic results are quite promising, despite the difficulties arising from the short wavelength of operation.- 26 February 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (2) , 022816
Comb-locked deep-ultraviolet laser system for precision mercury spectroscopy
Doppler-broadening gas thermometry is extended to the deep-ultraviolet domain using a comb-locked laser frequency chain, expressly developed for precision spectroscopy of mercury vapors at the wavelength of 253.7 nm, in coincidence with the intercombination line. The system is based on a double-stage second-harmonic generation process of an external-cavity diode laser at 1014.8 nm, which is frequency locked to a self-referenced optical-frequency-comb synthesizer by means of an efficient nonlinear frequency-mixing scheme. An absolute frequency axis in the UV region is produced by scanning the comb repetition rate, with the entire frequency chain following the reference comb tooth. The complete characterization of the phase noise of the comb-locked near-infrared laser demonstrates line-emission narrowing down to the limit imposed by the coherence of the comb teeth. After a proper processing of the phase noise, the Gaussian and Lorentzian components of the width of the UV radiation are determined. This is useful to estimate the instrumental perturbation to the probed mercury line for the aims of thermodynamic temperature metrology. In this regard, the preliminary spectroscopic results are quite promising, despite the difficulties arising from the short wavelength of operation.- Open Access
- 25 August 2023
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 25 (35) , 23614-23625
On the 12C2H2 near-infrared spectrum: absolute transition frequencies and an improved spectroscopic network at the kHz accuracy level
The absolute frequency of several C2H2 rovibrational transitions, carefully selected by the theory of spectroscopic network, has been measured with an accuracy of 15 kHz. Based on the MARVEL procedure, para- and ortho-energy levels were determined.
- 25 August 2023
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 25 (35) , 23614-23625
Open AccessOn the 12C2H2 near-infrared spectrum: absolute transition frequencies and an improved spectroscopic network at the kHz accuracy level
The absolute frequency of several C2H2 rovibrational transitions, carefully selected by the theory of spectroscopic network, has been measured with an accuracy of 15 kHz. Based on the MARVEL procedure, para- and ortho-energy levels were determined.
- 1 January 2023
- Published by Optica Publishing Group
- p. JTh2A.85
Absolute Frequency Referencing in the Deep-UV Region for Metrological Application
A comb-assisted frequency chain linking the UV domain to the near-infrared region has been developed with the aim of performing precision linear spectroscopy of mercury atoms at 253.7 nm for temperature metrology.
- 1 January 2023
- Published by Optica Publishing Group
- p. JTh2A.85
Absolute Frequency Referencing in the Deep-UV Region for Metrological Application
A comb-assisted frequency chain linking the UV domain to the near-infrared region has been developed with the aim of performing precision linear spectroscopy of mercury atoms at 253.7 nm for temperature metrology.