VDVittorio D'AGostino

Vittorio D'AGostino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vittorio D'AGostino has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Linear optical-feedback cavity ring-down spectroscopy using an interband cascade laser at 3- µ m wavelength

    by Vittorio D’AGostino, Emanuele Tofani, Stefania Gravina, Eugenio Fasci, Aniello Grado, Antonio Castrillo, Livio Gianfrani

    We report on a linear optical-feedback cavity ring-down spectrometer (LOF-CRDS) operating under ultra-high vacuum (UHV) conditions, designed for high-sensitivity detection of light hydrocarbons. The system employs an interband cascade laser (ICL) operating at 3 µ m, in coincidence with the strong absorption features of the asymmetric C-H stretching vibrational mode. Taking advantage of the passive optical feedback from the high-finesse linear cavity, the ICL emission linewidth is drastically narrowed, thus facilitating light coupling into the cavity. An empty-cavity ring-down time of about 18 µ s was measured, which translates into a cavity finesse of ∼37000 and a cavity-mode width of ∼9 kHz. As a result of an Allan-Werle analysis, performed at a fixed ICL frequency, we determined a minimum detectable absorption coefficient of ∼2.5×10 −10 cm −1 for an integration time of approximately 100 s. The spectrometer was tested on the R(25) component of the acetylene ν 3 vibrational band at 3352.2874 cm −1 . In this regard, we report on spectroscopic measurements of the C 2 H 2 partial pressure in the UHV chamber. For the selected line, the sensitivity leads to a limit of detection of 2.1×10 −8 mbar.


  • Open Access

    Leveraging Resonant Frequencies of an Optical Cavity for Spectroscopic Measurement of Gas Temperature and Concentration

    by Daniel Lisak, Vittorio D’aGostino, Szymon Wójtewicz, Agata Cygan, Marcin Gibas, Piotr Wcisło, Roman Ciuryło, Katarzyna Bielska

    We introduce a spectroscopic approach to primary gas thermometry, harnessing precise optical cavity resonance frequencies and molecular line intensity calculations. By utilizing CO (3-0) vibrational band lines and cavity mode dispersion spectroscopy, we achieve an uncertainty of 82 ppm (24 mK at 296 K) in line intensity ratio thermometry—over an order of magnitude lower than any previously reported spectroscopic thermometry at gas pressures above 1.2 kPa. This method extends high-precision spectroscopic thermometry across a pressure range an order of magnitude larger than prior techniques, enabling a fully optical, noncontact, and molecule-selective primary amount-of-substance measurement. We further demonstrate sub-permille uncertainty in gas concentration measurements across pressures from 50 Pa to 20 kPa, significantly enhancing the precision and versatility of spectroscopic gas metrology.


  • Cavity ring-down spectroscopy at 2-μm wavelength assisted by a comb-locked optical parametric oscillator

    by Vittorio D’aGostino, Eugenio Fasci, Muhammad Asad Khan, Stefania Gravina, Livio Gianfrani, Antonio Castrillo

    We report on a comb-locked cavity ring-down spectrometer developed for high-precision molecular spectroscopy at 2 μm. It is based on the use of an external-cavity diode laser that is offset-frequency locked to the signal output of a singly-resonant optical parametric oscillator. This latter acts as a reference laser, being locked to a self-referenced optical frequency comb, which in turn is stabilized against a GPS-disciplined Rb-clock. The performance of the spectrometer is investigated by probing a pair of N2O transitions belonging to hot vibrational bands. One of these has never, to the best of our knowledge, been observed before, and is included in the N2O line list of the ExoMol database. Absolute center frequencies are retrieved with a 1-σ global uncertainty of 108 kHz.


  • Demonstration of record sensitivity for water vapor detection by means of comb-locked cavity ring-down spectroscopy

    by Antonio Castrillo, Muhammad Asad Khan, Eugenio Fasci, Vittorio D’aGostino, Stefania Gravina, Livio Gianfrani

    We report on the development, characterization, and test of a comb-locked cavity ring-down spectrometer (CL-CRDS) operating in the spectral region around 1.39 µm. The system is based on the use of a hemispherical optical resonator with a finesse as high as ∼507000, which gives an empty-cavity ring-down time of about 285 µs. An Allan-Werle analysis on repeated acquisitions of the ring-down time at a fixed laser frequency suggests a minimum detectable absorption coefficient of 2×10−12cm−1 for the optimum integration time of 45 s. This limit can be exceeded by adopting the strategy of long-term spectral averaging. Taking advantage of the frequency stability guaranteed by the optical frequency comb, the CL-CRDS spectra were averaged over more than two days, thus removing efficiently the effect of mechanical, acoustic, and thermal noises. As a result, we could achieve a minimum detectable absorption coefficient as low as 3.7×10−13cm−1, which corresponds to a limit of detection for H2O in N2 of nine parts per trillion and a H2O partial pressure of 2×10−8 Pa (or 2×10−10 mbar). The potentialities of our approach are demonstrated by recording the absorption features of HD16O and HD18O in flows of ultra-high-purity N2 and ambient air, respectively.


  • Open Access

    On the 12C2H2 near-infrared spectrum: absolute transition frequencies and an improved spectroscopic network at the kHz accuracy level

    by Antonio Castrillo, Eugenio Fasci, Tibor Furtenbacher, Vittorio D'AGostino, Muhammad A. Khan, Stefania Gravina, Livio Gianfrani, Attila G. Császár

    The absolute frequency of several C2H2 rovibrational transitions, carefully selected by the theory of spectroscopic network, has been measured with an accuracy of 15 kHz. Based on the MARVEL procedure, para- and ortho-energy levels were determined.