Xiqi Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiqi Wu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Rui Li
Shanghai Jiao Tong University
8 shared publications - Xu Cai
Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, School of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
7 shared publications - Jiatao Yang
Shanghai Jiao Tong University
2 shared publications Cao Xi
Clean Energy Research Institute Company Ltd., China Huaneng Group Company Ltd., Beijing, China
1 shared publication- Chang Liu
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication Chao Huang
Hainan Jinpan Intelligent Technology Company Ltd., Longhua, Haikou, China
1 shared publication
Latest Publications
- 22 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (2) , 1159-1172
A Novel Battery Electrochemical Impedance Spectrum Measuring Method in Cascaded Energy Storage Systems
Electrochemical impedance spectroscopy (EIS) enables critical battery state estimation, yet conventional techniques require idle-time harmonic injection, distorting grid waveforms during operation and precluding real-time monitoring. To resolve this limitation, this paper proposes a novel current modulation method for online EIS measurement in cascaded energy storage systems (CHB-BESS). By exploiting the time-frequency duality principle (where time-domain multiplication corresponds to frequency-domain convolution), the proposed method generates target excitation frequencies through real-time current modulation in energy storage converter legs. This approach seamlessly integrates with the nearest level modulation (NLM) strategy of cascaded H-bridge systems, enabling online EIS measuring during normal operation – all while eliminating operational disruption and maintaining grid-side waveform integrity. Validation in MATLAB/Simulink and a down-scaled H-bridge prototype confirms the feasibility of the proposed method, demonstrating disturbance-free operation during normal system functioning while achieving multi-frequency EIS measurements with a mean average percentage error (MAPE) below 2.53%.
- 22 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (2) , 1159-1172
A Novel Battery Electrochemical Impedance Spectrum Measuring Method in Cascaded Energy Storage Systems
Electrochemical impedance spectroscopy (EIS) enables critical battery state estimation, yet conventional techniques require idle-time harmonic injection, distorting grid waveforms during operation and precluding real-time monitoring. To resolve this limitation, this paper proposes a novel current modulation method for online EIS measurement in cascaded energy storage systems (CHB-BESS). By exploiting the time-frequency duality principle (where time-domain multiplication corresponds to frequency-domain convolution), the proposed method generates target excitation frequencies through real-time current modulation in energy storage converter legs. This approach seamlessly integrates with the nearest level modulation (NLM) strategy of cascaded H-bridge systems, enabling online EIS measuring during normal operation – all while eliminating operational disruption and maintaining grid-side waveform integrity. Validation in MATLAB/Simulink and a down-scaled H-bridge prototype confirms the feasibility of the proposed method, demonstrating disturbance-free operation during normal system functioning while achieving multi-frequency EIS measurements with a mean average percentage error (MAPE) below 2.53%.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 15450-15465
Improved Grid Forming Control for Energy-Type STATCOM to Enhance Damping and Limit Multiple Currents
To improve the frequency and voltage stability of the modern power system, an energy-type STATCOM (ET-STATCOM) formed by embedding supercapacitors (SCs) in the dc bus of two film capacitor-type STATCOMs was designed, which can provide virtual inertia by boosting active power and voltage support through reactive power compensation. However, the issue of its grid forming control hangs in the balance. First, the favored virtual synchronous machine control may lead to over-charge/-discharge of SCs due to the active power-based control target. Second, although the classical matching control (MC) can regulate SC energy, none of its existing damping enhancement schemes is proper for the ET-STATCOM. Last but not least, the existing current limiting strategies can only limit the total current magnitude synthesized by the active and reactive currents, but not their respective magnitudes. To address these issues, an energy synchronization link founded on the MC and a novel damping enhancement scheme based on active power direct feedback are proposed, which helps the ET-STATCOM to integrate self-synchronization with power oscillation suppression capability, spontaneous inertia response, and autonomous management of SC energy. In addition, a multicurrent limiting control technique has been investigated to achieve overall and independent limiting of active and reactive currents. Simulations and a practical 35kV/30MVar/3MW/4s prototype validate the method's effectiveness.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 15450-15465
Improved Grid Forming Control for Energy-Type STATCOM to Enhance Damping and Limit Multiple Currents
To improve the frequency and voltage stability of the modern power system, an energy-type STATCOM (ET-STATCOM) formed by embedding supercapacitors (SCs) in the dc bus of two film capacitor-type STATCOMs was designed, which can provide virtual inertia by boosting active power and voltage support through reactive power compensation. However, the issue of its grid forming control hangs in the balance. First, the favored virtual synchronous machine control may lead to over-charge/-discharge of SCs due to the active power-based control target. Second, although the classical matching control (MC) can regulate SC energy, none of its existing damping enhancement schemes is proper for the ET-STATCOM. Last but not least, the existing current limiting strategies can only limit the total current magnitude synthesized by the active and reactive currents, but not their respective magnitudes. To address these issues, an energy synchronization link founded on the MC and a novel damping enhancement scheme based on active power direct feedback are proposed, which helps the ET-STATCOM to integrate self-synchronization with power oscillation suppression capability, spontaneous inertia response, and autonomous management of SC energy. In addition, a multicurrent limiting control technique has been investigated to achieve overall and independent limiting of active and reactive currents. Simulations and a practical 35kV/30MVar/3MW/4s prototype validate the method's effectiveness.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-6
Self-Adaptive and Optimal SOC Balancing Control for High Voltage Transformerless Battery Energy Storage System
State of charge (SOC) balancing is significant for high voltage transformerless (HVT) battery energy storage system (BESS) to utilize their full energy capacity. However, traditional methods face challenges in selecting proper balancing coefficient, resulting in either insufficient equalization speed due to conservative parameter, or battery overcurrent and SMs over-modulation with too large value. To overcome this challenge, the mechanism of overcurrent and overmodulation is revealed by theoretical analysis and four maximum coefficients corresponding four critical boundary conditions are deduced. Therefore, an optimal SOC balancing control with self-adaptive equalization coefficient is proposed in this article and is adaptive. 35kV/25MW/50MWh experimental results validate the effectiveness of the proposed control and its performance is compared with respect to conservative methods.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-6
Self-Adaptive and Optimal SOC Balancing Control for High Voltage Transformerless Battery Energy Storage System
State of charge (SOC) balancing is significant for high voltage transformerless (HVT) battery energy storage system (BESS) to utilize their full energy capacity. However, traditional methods face challenges in selecting proper balancing coefficient, resulting in either insufficient equalization speed due to conservative parameter, or battery overcurrent and SMs over-modulation with too large value. To overcome this challenge, the mechanism of overcurrent and overmodulation is revealed by theoretical analysis and four maximum coefficients corresponding four critical boundary conditions are deduced. Therefore, an optimal SOC balancing control with self-adaptive equalization coefficient is proposed in this article and is adaptive. 35kV/25MW/50MWh experimental results validate the effectiveness of the proposed control and its performance is compared with respect to conservative methods.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (4) , 4889-4901
Grid-Forming Control and Experimental Validation for High Voltage Transformerless Battery Energy Storage System
Advantages of single-device large capacity of combining with grid forming (GFM) control effectively help high voltage transformerless battery energy storage system (BESS) to support grid frequency and voltage stability. However, the transient stability characteristics of the converter under current-limiting mode during a fault and its capability to provide effective support to the grid are the major differences from conventional synchronous machines. Therefore, this article first investigates transient synchronization stability problems at occurrence of high-voltage and low-voltage fault-ride-through by theoretically deduced virtual power angle curves considering current limitation mode. Then, the strategies of enhancing transient synchronization stability in face of grid voltage sag and rise are proposed and verified by simulation results. Thereafter, an adaptive gain coefficient is proposed to be embedded into power feedback loop to improve the capability of fast low voltage supporting during fault occurrence. More importantly, a practical 35 kV/10 MW/5 MWh Lithium BESS engineering project validates the GFM control in steady charging/discharging operation and its voltage fault ride through support ability.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (4) , 4889-4901
Grid-Forming Control and Experimental Validation for High Voltage Transformerless Battery Energy Storage System
Advantages of single-device large capacity of combining with grid forming (GFM) control effectively help high voltage transformerless battery energy storage system (BESS) to support grid frequency and voltage stability. However, the transient stability characteristics of the converter under current-limiting mode during a fault and its capability to provide effective support to the grid are the major differences from conventional synchronous machines. Therefore, this article first investigates transient synchronization stability problems at occurrence of high-voltage and low-voltage fault-ride-through by theoretically deduced virtual power angle curves considering current limitation mode. Then, the strategies of enhancing transient synchronization stability in face of grid voltage sag and rise are proposed and verified by simulation results. Thereafter, an adaptive gain coefficient is proposed to be embedded into power feedback loop to improve the capability of fast low voltage supporting during fault occurrence. More importantly, a practical 35 kV/10 MW/5 MWh Lithium BESS engineering project validates the GFM control in steady charging/discharging operation and its voltage fault ride through support ability.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (3) , 1181-1191
Four Quadrant Operation Control for Cascade H-Bridge Converter-Based Battery Energy Storage System
Exposure to battery microcycles under low power factor for cascaded H-bridge (CHB) converter-based battery energy storage system (BESS) increases additional charge throughput and may accelerate lithium-ion battery cycle-aging. Aiming to eliminating battery microcycles current and further extend operating range, this paper proposes a complete four-quadrant operation control strategy for CHB-based BESS to avoid detrimental effects on cells. First, the battery current components with LC filter are decomposed quantitatively and feasible range of avoiding microcycles under four-quadrant operation are obtained theoretically. By vector decomposition of closed-loop generated modulation phase voltage, the grid-side power factor is not unaffected and all submodules power factor are compensated without exceeding the microcycles boundary. Besides, unified modulation strategy considering eliminating microcycles and inner-phase state of charge (SOC) equalization is analyzed and the system control diagram is given. At last, a 35kV/12MW/24MWh BESS simulation model and a downscaled prototype system with four cascaded 25.6V-rated Lithium-battery modules are built for principal validation. The experimental results at two different low power factor cases verify the feasibility of the proposed control strategy.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (3) , 1181-1191
Four Quadrant Operation Control for Cascade H-Bridge Converter-Based Battery Energy Storage System
Exposure to battery microcycles under low power factor for cascaded H-bridge (CHB) converter-based battery energy storage system (BESS) increases additional charge throughput and may accelerate lithium-ion battery cycle-aging. Aiming to eliminating battery microcycles current and further extend operating range, this paper proposes a complete four-quadrant operation control strategy for CHB-based BESS to avoid detrimental effects on cells. First, the battery current components with LC filter are decomposed quantitatively and feasible range of avoiding microcycles under four-quadrant operation are obtained theoretically. By vector decomposition of closed-loop generated modulation phase voltage, the grid-side power factor is not unaffected and all submodules power factor are compensated without exceeding the microcycles boundary. Besides, unified modulation strategy considering eliminating microcycles and inner-phase state of charge (SOC) equalization is analyzed and the system control diagram is given. At last, a 35kV/12MW/24MWh BESS simulation model and a downscaled prototype system with four cascaded 25.6V-rated Lithium-battery modules are built for principal validation. The experimental results at two different low power factor cases verify the feasibility of the proposed control strategy.
- 2 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (1) , 172-185
Extension of Zero-Voltage Switching Region of Wide Volage Ratio Range Dual-Active-Bridge Converter by LC Antiresonant Network
Zero-voltage switching (ZVS) for dual active bridge (DAB) with wide voltage conversion ratio has a contradiction with low conduction loss, especially under light power transmission. Root mean square (RMS) increase of inductor current is unavoidable just by optimizing modulation schemes. Inspired by the various frequency (VF) and various inductor (VI), this article proposes a DAB converter with the capability of regulating the impedance of the resonant tank to extend the ZVS region. With an LC antiresonant circuit in series with original inductor, the equivalent inductance of the resonant network of the proposed converter increases along with the switching frequency within the designed frequency range. Thereby, when the voltage mismatches and the transferred power decreases, a large impedance is obtained by slightly increasing frequency to help to achieve ZVS. Moreover, the proposed DAB is found that single phase shift (SPS) has nearly identical characteristics of ZVS and conduction loss compared with multiple phase shift modulation. The benefit of this is that the complexity of close-loop control is significantly reduced just considering the switching frequency and external shift phase. In addition, ZVS characteristics and optimal control method are analyzed in detail. Finally, a 2 kW 360-400V/40-60V prototype is built, and the main experimental results are provided to verify the feasibility of the proposed converter and soft switching range of all switches.
- 2 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (1) , 172-185
Extension of Zero-Voltage Switching Region of Wide Volage Ratio Range Dual-Active-Bridge Converter by LC Antiresonant Network
Zero-voltage switching (ZVS) for dual active bridge (DAB) with wide voltage conversion ratio has a contradiction with low conduction loss, especially under light power transmission. Root mean square (RMS) increase of inductor current is unavoidable just by optimizing modulation schemes. Inspired by the various frequency (VF) and various inductor (VI), this article proposes a DAB converter with the capability of regulating the impedance of the resonant tank to extend the ZVS region. With an LC antiresonant circuit in series with original inductor, the equivalent inductance of the resonant network of the proposed converter increases along with the switching frequency within the designed frequency range. Thereby, when the voltage mismatches and the transferred power decreases, a large impedance is obtained by slightly increasing frequency to help to achieve ZVS. Moreover, the proposed DAB is found that single phase shift (SPS) has nearly identical characteristics of ZVS and conduction loss compared with multiple phase shift modulation. The benefit of this is that the complexity of close-loop control is significantly reduced just considering the switching frequency and external shift phase. In addition, ZVS characteristics and optimal control method are analyzed in detail. Finally, a 2 kW 360-400V/40-60V prototype is built, and the main experimental results are provided to verify the feasibility of the proposed converter and soft switching range of all switches.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (5) , 4922-4930
A Novel Current Self-Balancing Method for High-Gain and High-Frequency Converter
Matrix transformer is deemed the most widely used structure for large current application due to its natural current sharing. However, multiple transformers suffer from large core volume and core loss, especially with high frequency operation. In this article, a novel current self-balancing method for high-gain and high-frequency converter is proposed. Only one magnetic core is employed and all secondary windings for large current are wrapped parallelly around the core. The H-bridges with two filtering inductors on the dc positive and negative bus are cascaded by these secondary windings to form a proposed cascaded H-bridge structure. Due to the large impedance in filter inductor loop in high frequency, the differential-mode current between different windings is largely suppressed and the current sharing of secondary windings and synchronous rectifier mosfets is achieved naturally. The filtering inductor can be easily implemented by using printed circuit board-routed inductance without iron core, which means that the power density and efficiency will not be impaired. A 750 V/48 V–2 kW unregulated LLC converter prototype is built and achieves the power density of 7 kW/L with maximum efficiency of 96.5%. With the proposed cascaded H-bridge structure, current self-balancing is achieved perfectly and the efficiency improvement reaches to 0.8% at full loading condition.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (5) , 4922-4930
A Novel Current Self-Balancing Method for High-Gain and High-Frequency Converter
Matrix transformer is deemed the most widely used structure for large current application due to its natural current sharing. However, multiple transformers suffer from large core volume and core loss, especially with high frequency operation. In this article, a novel current self-balancing method for high-gain and high-frequency converter is proposed. Only one magnetic core is employed and all secondary windings for large current are wrapped parallelly around the core. The H-bridges with two filtering inductors on the dc positive and negative bus are cascaded by these secondary windings to form a proposed cascaded H-bridge structure. Due to the large impedance in filter inductor loop in high frequency, the differential-mode current between different windings is largely suppressed and the current sharing of secondary windings and synchronous rectifier mosfets is achieved naturally. The filtering inductor can be easily implemented by using printed circuit board-routed inductance without iron core, which means that the power density and efficiency will not be impaired. A 750 V/48 V–2 kW unregulated LLC converter prototype is built and achieves the power density of 7 kW/L with maximum efficiency of 96.5%. With the proposed cascaded H-bridge structure, current self-balancing is achieved perfectly and the efficiency improvement reaches to 0.8% at full loading condition.
- 28 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (6) , 7387-7399
Modified LLC Resonant Converter With LC Antiresonant Circuit in Parallel Branch for Wide Voltage Range Application
In this article, a modified LLC resonant converter with LC antiresonant circuit in parallel branch is proposed. The proposed converter is derived by placing LC antiresonant circuit on parallel branch. In comparison with LLC resonant converter, the equivalent inductance of parallel branch of the proposed converter decreases along with switching frequency within regulating frequency range. This advantageous property contributes for that the turn- off current and circulating conduction loss in the primary side can be reduced at unity voltage conversion ratio due to large impedance of LC antiresonant circuit. Moreover, by optimizing resonant parameters design of parallel branch based on time-domain analysis, the magnetizing current is in close proximity to a sine wave and the conduction loss in the secondary side will be reduced, especially in the light load. A higher voltage conversion ratio can be achieved at low switching frequency due to decreased impedance in parallel branch. In addition, a design flowchart and a design practical case are given to help to implement an efficiency optimization algorithm to decide five resonant design parameters. Finally, a 2 kW 250 V—400 V-input and 48 V-output prototype is built, and the main experimental results are provided to verify the feasibility of the proposed converter and compare with LLC resonant converter. Comparative state-plane trajectories are depicted to compare their characteristics and to verify the model-domain analysis.
- 28 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (6) , 7387-7399
Modified LLC Resonant Converter With LC Antiresonant Circuit in Parallel Branch for Wide Voltage Range Application
In this article, a modified LLC resonant converter with LC antiresonant circuit in parallel branch is proposed. The proposed converter is derived by placing LC antiresonant circuit on parallel branch. In comparison with LLC resonant converter, the equivalent inductance of parallel branch of the proposed converter decreases along with switching frequency within regulating frequency range. This advantageous property contributes for that the turn- off current and circulating conduction loss in the primary side can be reduced at unity voltage conversion ratio due to large impedance of LC antiresonant circuit. Moreover, by optimizing resonant parameters design of parallel branch based on time-domain analysis, the magnetizing current is in close proximity to a sine wave and the conduction loss in the secondary side will be reduced, especially in the light load. A higher voltage conversion ratio can be achieved at low switching frequency due to decreased impedance in parallel branch. In addition, a design flowchart and a design practical case are given to help to implement an efficiency optimization algorithm to decide five resonant design parameters. Finally, a 2 kW 250 V—400 V-input and 48 V-output prototype is built, and the main experimental results are provided to verify the feasibility of the proposed converter and compare with LLC resonant converter. Comparative state-plane trajectories are depicted to compare their characteristics and to verify the model-domain analysis.
- 16 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (1) , 969-983
A Wide Output Voltage Range LLC Resonant Converter Based on Topology Reconfiguration Method
This paper proposes a wide output voltage range LLC resonant converter based on topology reconfiguration method (TRM). First, with different driving signals two operational modes of inverter circuit and rectifier circuit of the proposed topology are analyzed respectively. On this basis, the converter in whole voltage range has three variable operating modes considering voltage gain by different combination between two kinds of inverting modes and two kinds of rectifying modes. Thus compared with conventional LLC converter, the voltage gain range can be extended by four times within the same switching frequency range using TRM plus pulse-frequency modulation (PFM). Comprehensive analysis of circuit states and soft-switching condition in these three modes are presented. Moreover, design of voltage area division in three modes is discussed to arrive a better tradeoff between efficiency and power density. A design flowchart is given to help to implement an efficiency optimization algorithm. In addition, a smooth mode transition technique is proposed to avoid the rapid frequency change during reconfiguring modulation strategy. Finally, a 2kW 100V-900V output prototype is built, and main experimental results are provided to verify the effectiveness of the proposed topology and topology reconfiguration method.
- 16 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (1) , 969-983
A Wide Output Voltage Range LLC Resonant Converter Based on Topology Reconfiguration Method
This paper proposes a wide output voltage range LLC resonant converter based on topology reconfiguration method (TRM). First, with different driving signals two operational modes of inverter circuit and rectifier circuit of the proposed topology are analyzed respectively. On this basis, the converter in whole voltage range has three variable operating modes considering voltage gain by different combination between two kinds of inverting modes and two kinds of rectifying modes. Thus compared with conventional LLC converter, the voltage gain range can be extended by four times within the same switching frequency range using TRM plus pulse-frequency modulation (PFM). Comprehensive analysis of circuit states and soft-switching condition in these three modes are presented. Moreover, design of voltage area division in three modes is discussed to arrive a better tradeoff between efficiency and power density. A design flowchart is given to help to implement an efficiency optimization algorithm. In addition, a smooth mode transition technique is proposed to avoid the rapid frequency change during reconfiguring modulation strategy. Finally, a 2kW 100V-900V output prototype is built, and main experimental results are provided to verify the effectiveness of the proposed topology and topology reconfiguration method.