VNValentin A. Nechaev

Valentin A. Nechaev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Valentin A. Nechaev has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prognostic and predictive radiomic markers in head and neck cancer patients receiving chemoradiotherapy and systemic therapy

    by K. P. Boriskina, V. A. Nechaev, M. V. Nosova, O. A. Stativko, I. A. Pokataev, К. П. Борискина, В. А. Нечаев, М. В. Носова, О. А. Стативко, И. А. Покатаев

    Objective: To analyze the scientific literature on the potential of radiomics for predicting treatment response and outcomes in patients with head and neck cancers receiving systemic anticancer therapy and chemoradiotherapy. Materials and Methods. A literature search was conducted in the PubMed and eLIBRARY databases using keywords related to radiomics, systemic therapy and head and neck cancers. Original articles published over the past 10 years and meeting the inclusion criteria were selected. Of the 56 publications initially identified, 13 studies were included in the final review after exclusion of irrelevant articles. These studies were based on CT, MRI, and PET/CT data. The analysis focused on radiomic model development methods, types of extracted features, and their prognostic and predictive value. Results. The review demonstrated that radiomic models have substantial potential for predicting survival and treatment response to induction, palliative systemic therapy, as well as chemoradiotherapy. Combined clinical-radiomic models frequently were more effective compared with radiomic-only or clinical-only models. The use of machine learning and artificial intelligence algorithms was identified as a promising approach for optimizing prognostic models. Conclusion. Radiomics represents a promising tool for personalizing systemic therapy in head and neck cancers, enabling improved prognostic accuracy and optimization of treatment strategies. Standardization of methodologies, validation of models in large cohorts, and reduction of technical heterogeneity across studies are required for successful clinical implementation.

  • Open Access

    CT-perfusion parameters and reperfusion therapy in acute ischemic stroke: 24-hour NIHSS dynamics in a retrospective cohort.

    by Ilya L. Gubskiy, Mikhail M. Beregov, Nikolai E. Staroverov, Ivan A. Larionov, Kazachkov Yu. Kirill, Andrey P. Stepanchenko, Valentin A. Nechaev, Nataliya A. Marskaya, Nikolai A. Shamalov

    BACKGROUND: Neurological improvement after acute ischemic stroke depends on multiple clinical and imaging factors, including baseline stroke severity, infarct volume, and the success of reperfusion therapy. Despite technically successful recanalization, 30–50% of patients show no meaningful clinical improvement. AIM: To evaluate the impact of CT perfusion parameters, intravenous thrombolysis, and mechanical thrombectomy on 24‑hour neurological status dynamics measured by the NIHSS in patients with acute ischemic stroke due to large vessel occlusion. METHODS: This retrospective single‑center cohort included 52 patients with acute ischemic stroke caused by large vessel occlusion. CT perfusion data were analyzed using the ArchiMed PRO software. Ridge regression was applied to assess the effects of perfusion parameters, reperfusion therapies, and their characteristics on 24‑hour change in NIHSS. RESULTS: The model explained 44% of the variance in NIHSS change. Statistically significant predictors were baseline NIHSS score (p0.05), degree of recanalization on the TICI scale (p0.05; positive effect), and the performance of mechanical thrombectomy (p0.05; negative effect). Non‑significant trends were observed for infarct core volume (negative effect, p0.05), penumbra volume (positive effect, p0.05), and intravenous thrombolysis (positive effect, p0.05). CONCLUSION: Successful recanalization is the leading predictor of short‑term neurological improvement after acute ischemic stroke. CT perfusion parameters show trends consistent with previous literature; however, the limited statistical power of this cohort prevented these associations from reaching formal statistical significance.

  • Open Access

    Errors in the radiology of the pelvis: a review

    by I. V. Kondakov, V. A. Nechaev

    Aim. To systematize data on errors in the pelvic radiology. Methods. We searched for scientific publications in the information and analytical systems PubMed, e-library, Google Scholar over the past 15 years, using the keywords: “radiology errors in the pelvis imaging”, “diagnostic errors in pelvic radiology”, “bias in radiology”, “pitfalls in radiology”, “radiology mistakes”, “pearls in radiology”. Results. 36 articles dealing with errors in the pelvic radiology at various stages of examination were analyzed. The results of the analysis – the stages of the pelvic examination were highlighted and the main errors in each of them were listed. Conclusion . Errors and the prerequisites for their occurrence in the pelvic imaging can occur at different stages of the diagnostic process. Radiologists, clinicians, and technicians need to be aware of the specifics of errors at each stage of the study in order to minimize the risk of their occurrence and mitigate the consequences.

  • Open Access

    Validation of a Russian automated CT perfusion processing system for ischemic stroke

    by Ilya L. Gubskiy, Mikhail M. Beregov, Nikolai E. Staroverov, Ivan A. Larionov, Kirill Yu. Kazachkov, Andrey P. Stepanchenko, Valentin A. Nechaev, Nataliya A. Marskaya, Nikolay A. Shamalov, Губский Илья Леонидович

    BACKGROUND: Automated computed tomography (CT) perfusion analysis systems are critical for patient selection for reperfusion therapy in acute ischemic stroke. Systems such as RAPID (iSchemaView/RapidAI, USA) and Olea Sphere (Olea Medical, France) are widely used in clinical practice; however, a validated domestic system for automated CT perfusion processing is lacking in the Russian Federation. Among similar systems that have a registration certificate in the Russian Federation, Vitrea (Canon Medical Systems, USA, Japan) is available in clinical practice. AIM: To validate the Russian system ArchiMed PRO Chronos by comparing it with the Vitrea (Canon Medical Systems, USA, Japan) software for quantitative assessment of ischemic core and critical hypoperfusion area. METHODS: A retrospective study included 52 patients with acute ischemic stroke caused by large vessel occlusion and symptom onset within 24 hours. Correlation between systems was assessed for ischemic core volume and critical hypoperfusion area determination. RESULTS: Strong correlation was found between systems for ischemic core volume (r=0.95) and critical hypoperfusion area (r=0.85). After excluding studies with inadequate segmentation, correlation improved to r=0.98 and r=0.93, respectively. Adequate segmentation was achieved in 84.6% of cases for both systems. No statistically significant differences between systems were detected (p 0.05). CONCLUSION: The ArchiMed PRO Chronos system demonstrated excellent agreement with Vitrea and can be used for quantitative CT perfusion analysis and patient selection for reperfusion therapy.


  • Open Access

    Head and neck computed tomography dataset with lymph node assessment according to the Node-RADS classification

    by Yuriy A. Vasilev, Anna P. Gonchar, Oleg I. Mynko, Daria S. Kontorovich, Ivan A. Blokhin, Roman V. Reshetnikov, Valentin A. Nechaev

    BACKGROUND: Diagnosis of head and neck malignancies and prediction of lymph node metastases are essential for determining the appropriate treatment strategy. Artificial intelligence-based systems for automated lymph node analysis have been developed for this purpose. The predictive accuracy of such systems can be enhanced by training on both radiological and clinical data. AIM: To prepare a head and neck computed tomography dataset for the development of artificial intelligence systems designed to detect lymph node metastases. METHODS: An anonymized dataset comprising contrast-enhanced head and neck computed tomography scans and associated clinical information was prepared. Computed tomography examinations were performed in patients aged 18 years with histologically confirmed malignancies, free of dental metallic hardware artifacts at the level of the target lymph nodes classified as Node-RADS categories 1 and 5, and without motion artifacts. The data were obtained from a single clinical center and extracted from the Unified Radiological Information Service / Unified Medical Information and Analytical System of Moscow. Computed tomography examinations were conducted between 2020 and 2023 using Toshiba Aquilion scanners. The dataset includes images acquired during the venous phase of contrast enhancement. Scanning was performed 70 seconds after peak aortic lumen attenuation (130 HU) was reached. A total of 75 lymph nodes classified as Node-RADS category 5 were annotated by three radiologists, each with 3 years of clinical experience. RESULTS: The dataset contains 82 DICOM files with a total volume of 18.6 GB. To construct the dataset, head and neck computed tomography scans of outpatients from Oncology Center No. 1 of the Moscow City Hospital named after S.S. Yudin were selected between April 2024 and May 2025. The mean patient age was 62 ± 11.1 years (range, 33–84 years). CONCLUSION: A publicly available dataset of contrast-enhanced head and neck computed tomography scans, along with clinical data from patients with malignancies, has been prepared and released. The dataset includes cervical lymph node annotations according to the Node-RADS classification (categories 1 and 5). It is intended for the development and validation of artificial intelligence algorithms for the detection and assessment of lymph nodes in head and neck oncology.

  • Open Access

    Risk Factors for the Occurrence of Interpretative Errors in Radiology

    by V. A. Nechaev, A. Yu. Vasiliev, А. Ю. Васильев

    Background. The results of radiological examinations largely determine the subsequent treatment strategy. Errors occur in 20–40% of cases and can have serious negative consequences for patients. It is crucial to understand the causes of these errors, which may impact the possibility of reducing their incidence. Objective: to identify the main risk factors for interpretative errors in radiology when analyzing radiation studies. Material and methods. A retrospective analysis of 89 imaging studies with interpretative errors was conducted. The largest share had computed tomography (73%), followed by magnetic resonance imaging (15.7%), and radiography (11.3%). Errors were classified by prognostic factors from Category 1 (minimal changes) to Category 5 (critical). The time from initial examination to erroneous conclusions ranged from 0 to 2162 days, with an average of 80.6 days. Results. The most common errors were detected in studies of brain (33.7%), chest (24.7%), and abdomen (15.7%). Incorrect interpretations included neoplastic lesions (39.3%), inflammatory changes (28.1%), and vascular pathology (22.5%). The most frequently observed errors were those with prognostic Category 4, requiring changes in treatment tactics (69.7%). A number of risk factors for the occurrence of interpretative errors were identified: the leading one was “incomplete analysis of semiotic features” (42.7%), followed by “anamnesis” (19.1%) and “insufficient knowledge” (12.4%). However, in 18% of cases, no risk factors were identified. Conclusion. Identification of risk factors for the occurrence of diagnostic errors in the analysis of radiological studies is necessary for the subsequent development of preventive measures that should reduce the incidence of interpretative errors and improve the quality of radiological diagnostics in general.

  • Open Access

    Atrioesophageal fistula after radiofrequency catheter ablation for atrial fibrillation: clinical case

    by Vladislav V. Gaskin, Anna A. Gaskina, Amir G. Masri, Valentin A. Nеchaev, Arnold E. Markarov

    BACKGROUND: Atrioesophageal fistula is a rare complication following radiofrequency catheter ablation for atrial fibrillation and is associated with high mortality. Clinical manifestations of atrioesophageal fistula are nonspecific and may include fever, neurological symptoms, and sepsis, which complicates timely diagnosis. A literature search was conducted in international databases PubMed, Google Scholar and eLibrary for the last five years (2019–2024) using the keywords “atrioesophageal fistula” and “complications of radiofrequency catheter ablation.” Thirty articles were selected for review. CLINICAL CASE DESCRIPTION: The aim of this publication is to present a rare case of atrioesophageal fistula development after radiofrequency catheter ablation in a 53-year-old female patient. The features of the clinical course, diagnostic challenges, as well as possible approaches to early recognition, prevention, and treatment of this complication were analyzed. CONCLUSION: Even when diagnosed early, atrioesophageal fistula carries an exceedingly poor prognosis. This underscores the critical need for sustained clinical vigilance, improved prevention strategies, and the establishment of standardized management guidelines for suspected cases of this lethal complication.

  • Open Access

    Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT

    by Valentin A. Nechaev, Nataliya Y. Kashtanova, Evgenii V. Kopeykin, Umamat M. Magomedova, Maria S. Gribkova, Anton V. Hardin, Marina I. Sekacheva, Varvara D. Sanikovich, Valeria Y. Chernina, Victor A. Gombolevskiy

    Background/Objectives: Chest, abdominal, and pelvic computed tomography (CT) with intravenous contrast is widely used for tumor staging, treatment planning, and therapy monitoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. We aimed to evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Results: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated features, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant findings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high diagnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.

  • Open Access

    Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT

    by Valentin Nechaev, Nataliya Kashtanova, Evgenii Kopeykin, Umamat Magomedova, Maria Gribkova, Anton Hardin, Мaina Sekacheva, Varvara Sanikovich, Valeria Chernina, Victor Gombolevskiy

    Background: Chest, abdominal, and pelvic computed tomography (CT) with intrave-nous contrast is widely used for tumor staging, treatment planning, and therapy mon-itoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. Purpose: To evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Re-sults: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated fea-tures, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant find-ings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high di-agnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.

  • Open Access

    High-resolution ultrasound in the late period of dynamic follow-up after photodynamic therapy for basal cell carcinoma of the head and neck skin

    by S. S. Khoruzhaya, A. Yu. Vasil′Yev, V. E. Sеmin, V. A. Nechaev, А. Ю. Васильев

    Purpose of the study. The objective of this study was to ascertain the potential of high-resolution ultrasound in evaluating the outcomes of photodynamic therapy for basal cell carcinoma of the head and neck in the late period. Materials and Methods . A total of 101 patients were examined in the late period (3–6–12 months) after photodynamic therapy (32 men and 69 women) with ages ranging from 40 to 93 years. All patients underwent a high-resolution ultrasound examination of the treated area using a Philips Epic 7 expert class device with a high-frequency linear matrix transducer (eL18-4) with a scanning range of 2–22 MHz and Microflow Imaging technology. Results: The results of the study revealed that ultrasonic diagnostics can effectively evaluate the treatment's effectiveness and exclude the recurrence of the primary disease following photodynamic therapy for basal cell carcinoma of the head and neck during the period of scar changes formation. The ultrasound images obtained at 3, 6, and 12 months following photodynamic therapy revealed various changes in the skin and adjacent soft tissues, depending on the extent of scar formation. These changes exhibited unique characteristics and were influenced by numerous factors. Conclusions. Ultrasound diagnostics has been proven to be a reliable, non-invasive, and cost-effective research method. It provides a means to assess the degree of reparative changes in the skin following treatment and to rule out the possibility of disease recurrence.