Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT
Authors:
- Valentin NechaevVNValentin Nechaev
- Nataliya KashtanovaNKNataliya Kashtanova
- Evgenii KopeykinEKEvgenii Kopeykin
- Umamat MagomedovaUMUmamat Magomedova
- Maria GribkovaMGMaria Gribkova
- Anton HardinAHAnton Hardin
- Мaina SekachevaМaina Sekacheva
- Varvara SanikovichVSVarvara Sanikovich
- Valeria CherninaVCValeria Chernina
- Victor GombolevskiyVGVictor Gombolevskiy
Preprint
- 29 October 2025
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background: Chest, abdominal, and pelvic computed tomography (CT) with intrave-nous contrast is widely used for tumor staging, treatment planning, and therapy mon-itoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. Purpose: To evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Re-sults: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated fea-tures, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant find-ings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high di-agnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.Keywords
All Related Versions
- Version 1, 2025-10-29, Preprints
- Published version: Diagnostics, 15 (21), 2778.
This publication has 21 references indexed in Scilit:
- AI in radiology: From promise to practice − A guide to effective integrationEuropean Journal of Radiology, 2024
- Clinical impact of AI in radiology department management: a systematic reviewLa radiologia medica, 2024
- Frequency and characteristics of errors by artificial intelligence (AI) in reading screening mammography: a systematic reviewBreast Cancer Research and Treatment, 2024
- Can incorrect artificial intelligence (AI) results impact radiologists, and if so, what can we do about it? A multi-reader pilot study of lung cancer detection with chest radiographyEuropean Radiology, 2023
- Assessing clinical applicability of COVID-19 detection in chest radiography with deep learningScientific Reports, 2022
- Effect of a comprehensive deep-learning model on the accuracy of chest x-ray interpretation by radiologists: a retrospective, multireader multicase studyThe Lancet Digital Health, 2021
- Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysisnpj Digital Medicine, 2021
- INtravenous Contrast computed tomography versus native computed tomography in patients with acute Abdomen and impaired Renal functiOn (INCARO): a multicentre, open-label, randomised controlled trial - study protocolBMJ Open, 2020
- Common Resident Errors When Interpreting Computed Tomography of the Abdomen and Pelvis: A Review of Types, Pitfalls, and Strategies for ImprovementCurrent Problems in Diagnostic Radiology, 2019
- STARD 2015: an updated list of essential items for reporting diagnostic accuracy studiesBMJ, 2015