UMUmamat M. Magomedova

Umamat M. Magomedova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Umamat M. Magomedova has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT

    by Valentin A. Nechaev, Nataliya Y. Kashtanova, Evgenii V. Kopeykin, Umamat M. Magomedova, Maria S. Gribkova, Anton V. Hardin, Marina I. Sekacheva, Varvara D. Sanikovich, Valeria Y. Chernina, Victor A. Gombolevskiy

    Background/Objectives: Chest, abdominal, and pelvic computed tomography (CT) with intravenous contrast is widely used for tumor staging, treatment planning, and therapy monitoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. We aimed to evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Results: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated features, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant findings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high diagnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.

  • Open Access

    Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT

    by Valentin Nechaev, Nataliya Kashtanova, Evgenii Kopeykin, Umamat Magomedova, Maria Gribkova, Anton Hardin, Мaina Sekacheva, Varvara Sanikovich, Valeria Chernina, Victor Gombolevskiy

    Background: Chest, abdominal, and pelvic computed tomography (CT) with intrave-nous contrast is widely used for tumor staging, treatment planning, and therapy mon-itoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. Purpose: To evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Re-sults: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated fea-tures, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant find-ings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high di-agnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.

  • Open Access

    A Rare Case of Recurrent Retroperitoneal Liposarcoma with Metastasis to Soft Tissues

    by U. M. Magomedova, V. A. Nechaev, E. A. Kulikova, A. L. Yudin, E. A. Yumatova

    The article describes a clinical case of recurrent retroperitoneal liposarcoma with a rare type of distant metastasis in a patient undergoing surgical and chemotherapy treatment in Cancer Center No. 1 (branch of Yudin City Clinical Hospital) since May 2021. The patient's medical history and computed tomography (CT) results were analyzed. The use of CT remains an extremely important stage in the examination of patients with retroperitoneal liposarcoma for assessing local prevalence, identifying distant secondary lesions, including ones to soft tissues.