Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takunori Shimazaki has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preliminary Quantitative Evaluation of the Optimal Colour System for the Assessment of Peripheral Circulation from Applied Pressure Using Machine Learning

    by Masanobu Tsurumoto, Takunori Shimazaki, Jaakko Hyry, Yoshifumi Kawakubo, Takeshi Yokoyama, Daisuke Anzai

    Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.


  • Open Access

    A Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors

    by Mitsuhiro Fukuda, Jaakko Hyry, Ryosuke Omoto, Takunori Shimazaki, Takumi Kobayashi, Daisuke Anzai

    Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance measurements are prone to interference from body movements. Conversely, a capnometer coupled with a ventilator offers a method of measuring the respiratory rate that is unaffected by body movements. However, capnometers are mainly used to evaluate respiration when using a ventilator or an Ambu bag by measuring the CO2 concentration at the breathing circuit, and they are not used only to measure the respiratory rate. Furthermore, capnometers are not suitable as wearable devices because they require intubation or a mask that covers the nose and mouth to prevent air leaks during the measurement. In this study, we developed a reliable system for measuring the respiratory rate utilizing a small wearable MOx sensor that is unaffected by body movements and not connected to the breathing circuit. Subsequently, we conducted experimental assessments to gauge the accuracy of the rate estimation achieved by the system. In order to avoid the effects of abnormal states on the estimation accuracy, we also evaluated the classification performance for distinguishing between normal and abnormal respiration using a one-class SVM-based approach. The developed system achieved 80% for both true positive and true negative rates. Our experimental findings reveal that the respiratory rate can be precisely determined without being influenced by body movements.

  • Open Access

    Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging

    by Rumi Iwai, Takunori Shimazaki, Jaakko Hyry, Yoshifumi Kawakubo, Masashi Fukuhara, Hiroki Aono, Shingo Ata, Takeshi Yokoyama, Daisuke Anzai

    Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference (p=0.0002) between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.


  • Development and Preliminary Evaluation of Remote Pacemaker Monitoring System Using Large Language Model

    by Rumi Iwai, Takunori Shimazaki, Mitsuhiro Fukuda, Takanao Mine, Shingo Ata, Takeshi Yokoyama, Daisuke Anzai

    A remote monitoring system that periodically transmits information stored in the pacemaker from patients' homes to a hospital is now in widespread use. However, the system requires access to the vendor's cloud server via a browser and consists of date-by-date PDF files, making the creation of aggregate data a significant burden. Since the release of commercially available systems such as ChatG PT, various large language models (LLMs) have been widely used, leading to that semantic search, which can perform searches that take into account the meaning of language, has attracted attention. In this study, we constructed an LLM - based remote monitoring system. Then, as a preliminary evaluation, we examined its effectiveness for RM operations based on the accuracy of RM data aggregation and work time.


  • A Study on Stenosis Detection Based on Non-contact Thrill Wave Imaging and Gradient-Boosting Decision Tree

    by Takunori Shimazaki, Yoshifumi Kawakubo, Rumi Iwai, Masashi Fukuhara, Hiroki Aono, Jun Mitsudo, Yuhei Hayashi, Shingo Ata, Takeshi Yokoyama, Daisuke Anzai

    Hemodialysis therapy generally requires a special blood vessel called an arteriovenous fistula (AVF), which is surgically anastomosed between an artery and a vein. Since an AVF often becomes stenosis, palpation is used to palpate the vessel wall vibrations, which is called thrill wave, before and after hemodialysis treatment. This method is widely used, especially in Japan, because of its simplicity. However, several problems in the palpation has been pointed out in terms of reliability because the palpation requires contact diagnosis. In order to solve the problems in the conventional contact palpation, we developed a thrill wave measurement device using non-contact imaging based on an optical technology. Then, we introduced a gradient-boosting decision tree algorithm to detect stenosis in AVFs. The experimental results showed that true positive rate (TPR) = 92.3%, true negative rate (TNR) = 76.7%, false positive rate (FPR) = 7.7% and false negative rate (FNR) = 23.3% to identify normal and stenotic AVFs.


  • Open Access

    Quantification and Visualization of Reliable Hemodynamics Evaluation Based on Non-Contact Arteriovenous Fistula Measurement

    by Rumi Iwai, Takunori Shimazaki, Yoshifumi Kawakubo, Kei Fukami, Shingo Ata, Takeshi Yokoyama, Takashi Hitosugi, Aki Otsuka, Hiroyuki Hayashi, Masanobu Tsurumoto, et al.

    The condition of arteriovenous fistula (AVF) blood flow is typically checked by using auscultation; however, auscultation should require a qualitative judgment dependent on the skills of doctors, and further attention to contact infection is required. For these reasons, this study developed a non-contact and non-invasive medical device to measure the pulse wave of AVFs by applying optical imaging technology. As a first step toward realization of the quantification judgment based on non-contact AVF measurement, we experimentally validated the developed system, whereby the hemodynamics of 168 subjects were visually and quantitatively evaluated based on clinical tests. Based on the evaluation results, the fundamental statistical characteristics of the non-contact measurement, including the average and median values, and distribution of measured signal-to-noise power ratio, were demonstrated. The clinical test results contributed to the future construction of quantified criteria for the AVF condition with the non-contact measurement.


  • Open Access

    Heat Stroke Prevention in Hot Specific Occupational Environment Enhanced by Supervised Machine Learning with Personalized Vital Signs

    by Takunori Shimazaki, Daisuke Anzai, Kenta Watanabe, Atsushi Nakajima, Mitsuhiro Fukuda, Shingo Ata

    Recently, wet-bulb globe temperature (WBGT) has attracted a lot of attention as a useful index for measuring heat strokes even when core body temperature cannot be available for the prevention. However, because the WBGT is only valid in the vicinity of the WBGT meter, the actual ambient heat could be different even in the same room owing to ventilation, clothes, and body size, especially in hot specific occupational environments. To realize reliable heat stroke prevention in hot working places, we proposed a new personalized vital sign index, which is combined with several types of vital data, including the personalized heat strain temperature (pHST) index based on the temperature/humidity measurement to adjust the WBGT at the individual level. In this study, a wearable device was equipped with the proposed pHST meter, a heart rate monitor, and an accelerometer. Additionally, supervised machine learning based on the proposed personalized vital index was introduced to improve the prevention accuracy. Our developed system with the proposed vital sign index achieved a prevention accuracy of 85.2% in a hot occupational experiment in the summer season, where the true positive rate and true negative rate were 96.3% and 83.7%, respectively.


  • Performance Prediction of Wireless Vital Data Collection System for Exercisers by a Network Simulator

    by Takuma Hamagami, Shinsuke Hara, Hiroyuki Yomo, Ryusuke Miyamoto, Yasutaka Kawamoto, Takunori Shimazaki, Hiroyuki Okuhata

    When we collect vital data from exercisers by putting wireless sensor nodes to them, the reliability of the wireless data collection is dependent on the position of node on the body of exerciser, therefore, in order to determine the suitable body position, it is essential to evaluate the data collection performances by changing the body positions of nodes in experiments involving human subjects. However, their fair comparison is problematic, because the experiments have no repeatability, that is, we cannot evaluate the performances for multiple body positions in an experiment at the same time. In this paper, we predict the performances by a software network simulator. Using two main functions such as a channel state function and a mobility function, the network simulator can repeatedly generate the same channel and mobility conditions for nodes. Numerical result obtained by the network simulator shows that when collecting vital data from twenty two footballers in a game, among three body position such as waist, forearm and calf, the forearm position gives the highest data collection rate and the predicted data collection rates agree well with the ones obtained by an experiment involving real subjects.