Jaakko Hyry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaakko Hyry has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Anzai
Osaka Metropolitan University
12 shared publications - Takumi Kobayashi
Osaka Metropolitan University
6 shared publications - Takunori Shimazaki
Department of Clinical Engineering, Faculty of Health Care, Jikei University of Health Care Sciences, Osaka 532-0003, Japan
3 shared publications - Manato Fujimoto
Osaka Metropolitan University
2 shared publications - Takeshi Yokoyama
Department of Dental Anesthesiology, Faculty of Dental Science, Kyushu University, Fukuoka 812-8582, Japan
2 shared publications Takumi Kobayashi
Nagoya Institute of Technology, Nagoya, Aichi, Japan
2 shared publications
Latest Publications
- 10 October 2026
- Published by Springer Nature
- p. 74-80
Performance Evaluation on Multiple Implantable Device Localization Based on Magnetic Fields
- 10 October 2026
- Published by Springer Nature
- p. 74-80
Performance Evaluation on Multiple Implantable Device Localization Based on Magnetic Fields
- 10 October 2026
- Published by Springer Nature
- p. 340-346
Performance Evaluation on IEEE 802.15.6ma-Based UWB Ranging in Coexistence Environment
- 10 October 2026
- Published by Springer Nature
- p. 340-346
Performance Evaluation on IEEE 802.15.6ma-Based UWB Ranging in Coexistence Environment
- 10 October 2026
- Published by Springer Nature
- p. 57-73
Evaluation of 3-Dimensional In-Body Device Localization Using Machine Learning Algorithms with Reduced Training Data
- 10 October 2026
- Published by Springer Nature
- p. 57-73
Evaluation of 3-Dimensional In-Body Device Localization Using Machine Learning Algorithms with Reduced Training Data
- 10 October 2026
- Published by Springer Nature
- p. 247-254
Development of Passive-Type Implantable VNS Device with Multiple Receive Coils
- 10 October 2026
- Published by Springer Nature
- p. 247-254
Development of Passive-Type Implantable VNS Device with Multiple Receive Coils
- 10 October 2026
- Published by Springer Nature
- p. 331-339
Preliminary Study on Adaptive MAC Protocol for Reliable Control in IEEE 802.15.6ma BANs
- 10 October 2026
- Published by Springer Nature
- p. 331-339
Preliminary Study on Adaptive MAC Protocol for Reliable Control in IEEE 802.15.6ma BANs
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 10 (3) , 410-418
Power and Waveform Optimization for Implant Ultra-Wideband Communications Enhanced by Dynamic Sparse Control
It is important to determine efficient transmit power for ultra-wideband (UWB) communications, especially in implantable medical devices, to overcome large signal attenuation from a human body and to ensure reliable high-speed transmission. This paper investigates the optimization of transmit pulse waveform to improve the communication characteristics under two regulations: extremely low power (ELP) regulation and specific absorption rate (SAR). Furthermore, a sparse control method is introduced to further optimize the balance between the performance and system complexity for medical implant applications. The proposed system achieved an average throughput of 40.3 Mbps as compared with the average throughput of 5.7 Mbps of the conventional UWB communication system.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 10 (3) , 410-418
Open AccessPower and Waveform Optimization for Implant Ultra-Wideband Communications Enhanced by Dynamic Sparse Control
It is important to determine efficient transmit power for ultra-wideband (UWB) communications, especially in implantable medical devices, to overcome large signal attenuation from a human body and to ensure reliable high-speed transmission. This paper investigates the optimization of transmit pulse waveform to improve the communication characteristics under two regulations: extremely low power (ELP) regulation and specific absorption rate (SAR). Furthermore, a sparse control method is introduced to further optimize the balance between the performance and system complexity for medical implant applications. The proposed system achieved an average throughput of 40.3 Mbps as compared with the average throughput of 5.7 Mbps of the conventional UWB communication system.
- Open Access
Preliminary Quantitative Evaluation of the Optimal Colour System for the Assessment of Peripheral Circulation from Applied Pressure Using Machine Learning
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.
Open AccessPreliminary Quantitative Evaluation of the Optimal Colour System for the Assessment of Peripheral Circulation from Applied Pressure Using Machine Learning
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.
- Open Access
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 175598-175606
Peak-Forming-Enhanced Electromagnetic Imaging Method for Implantable Device Localization
To improve the quality of medical treatment using implantable devices, accurate location information for implantable devices must be acquired and reliable implant communications for vital data transmission must be ensured. This paper focuses on an electromagnetic (EM) imaging-based method using scattered EM fields, which enables implant device localization without requiring any information regarding the human body structure. However, in conventional EM imaging-based methods, it is difficult to accurately estimate the capsule location at high frequencies because of significant signal attenuation. Herein, we propose an EM imaging-based localization method enhanced by peak-formed incident electric fields generated by overlaying multiple EM waves. Our proposed method utilizes information regarding scattered electric fields by sweeping the peak location without increasing the measurement points. The performance improvement by the proposed method was evaluated in two- and three-dimensional computer simulations such that the proposed EM imaging-based localization can be further optimized to achieve precise estimation accuracy at a high frequency of 2.4 GHz.
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 175598-175606
Open AccessPeak-Forming-Enhanced Electromagnetic Imaging Method for Implantable Device Localization
To improve the quality of medical treatment using implantable devices, accurate location information for implantable devices must be acquired and reliable implant communications for vital data transmission must be ensured. This paper focuses on an electromagnetic (EM) imaging-based method using scattered EM fields, which enables implant device localization without requiring any information regarding the human body structure. However, in conventional EM imaging-based methods, it is difficult to accurately estimate the capsule location at high frequencies because of significant signal attenuation. Herein, we propose an EM imaging-based localization method enhanced by peak-formed incident electric fields generated by overlaying multiple EM waves. Our proposed method utilizes information regarding scattered electric fields by sweeping the peak location without increasing the measurement points. The performance improvement by the proposed method was evaluated in two- and three-dimensional computer simulations such that the proposed EM imaging-based localization can be further optimized to achieve precise estimation accuracy at a high frequency of 2.4 GHz.
- Open Access
- 16 August 2024
- Published by MDPI AG in Information
- Vol. 15 (8) , 492
A Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors
Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance measurements are prone to interference from body movements. Conversely, a capnometer coupled with a ventilator offers a method of measuring the respiratory rate that is unaffected by body movements. However, capnometers are mainly used to evaluate respiration when using a ventilator or an Ambu bag by measuring the CO2 concentration at the breathing circuit, and they are not used only to measure the respiratory rate. Furthermore, capnometers are not suitable as wearable devices because they require intubation or a mask that covers the nose and mouth to prevent air leaks during the measurement. In this study, we developed a reliable system for measuring the respiratory rate utilizing a small wearable MOx sensor that is unaffected by body movements and not connected to the breathing circuit. Subsequently, we conducted experimental assessments to gauge the accuracy of the rate estimation achieved by the system. In order to avoid the effects of abnormal states on the estimation accuracy, we also evaluated the classification performance for distinguishing between normal and abnormal respiration using a one-class SVM-based approach. The developed system achieved 80% for both true positive and true negative rates. Our experimental findings reveal that the respiratory rate can be precisely determined without being influenced by body movements.
- 16 August 2024
- Published by MDPI AG in Information
- Vol. 15 (8) , 492
Open AccessA Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors
Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance measurements are prone to interference from body movements. Conversely, a capnometer coupled with a ventilator offers a method of measuring the respiratory rate that is unaffected by body movements. However, capnometers are mainly used to evaluate respiration when using a ventilator or an Ambu bag by measuring the CO2 concentration at the breathing circuit, and they are not used only to measure the respiratory rate. Furthermore, capnometers are not suitable as wearable devices because they require intubation or a mask that covers the nose and mouth to prevent air leaks during the measurement. In this study, we developed a reliable system for measuring the respiratory rate utilizing a small wearable MOx sensor that is unaffected by body movements and not connected to the breathing circuit. Subsequently, we conducted experimental assessments to gauge the accuracy of the rate estimation achieved by the system. In order to avoid the effects of abnormal states on the estimation accuracy, we also evaluated the classification performance for distinguishing between normal and abnormal respiration using a one-class SVM-based approach. The developed system achieved 80% for both true positive and true negative rates. Our experimental findings reveal that the respiratory rate can be precisely determined without being influenced by body movements.
- Open Access
Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference () between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.Open AccessReliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference () between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.