Huihui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huihui Wang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Qinghua Deng
Xi'an Jiaotong University, China
4 shared publications - Zhenping Feng
School of Energy and Power Engineering, Xi'an Jiaotong University , Xi'an 710049, China
4 shared publications - Wei He
Xi’an Jiaotong University Shaanxi Engineering Laboratory of Turbomachinery and Power Equipment; Institute of Turbomachinery; School of Energy & Power Engineering Xi’an 710049 , China
2 shared publications - Xiying Niu
Harbin Marine Boiler and Turbine Research Institute , Harbin 150078 , China
1 shared publication
Latest Publications
- 8 May 2024
- Published by Wiley in Journal of Turbomachinery
- Vol. 146 (10)
Action Mechanism of Film Extraction on Channel Impingement Cooling for Blade Leading Edge Using Large Eddy Simulation
Various internal cooling techniques combined with external film cooling are applied to cool gas turbine blades, and the coolant extraction can cause variations in internal flow structures and cooling effectiveness. Effects of film extraction under different film hole diameters and coolant mass flow ratio on heat transfer and flow characteristics of channel impingement cooling are presented using large eddy simulation (LES) in this article. The current work was undertaken based on turbine blade dimensions and turbine operating conditions. The results indicate that film extraction coupled with the curvature-induced instability dominates flow patterns and heat transfer in the channel impingement cooling structure with a film hole, especially in the bend region corresponding to the leading edge of turbine blades. Film coolant extraction can disrupt the streamwise counterrotating flow circulation pair. The latter is caused by the curvature-induced instability and is also the major driver of multilongitudinal vortices. The hole edge vortex generated by coolant bleed amplifies heat transfer at the leading edge, and the effect is more significant as the film hole diameter increases. Conversely, heat transfer coefficient downstream of the cooling channel decreases due to a reduction in cooling air. The increasing film bleed flow increases overall total pressure loss, while flow loss in the cooling channel decreases because of the weakened flow circulations and reduced coolant mass flow. This work provides an in-depth insight into the cooling performance of channel impingement cooling with film extraction, contributing to designing film cooling for turbine blades with multichannel wall jet cooling.
- 8 May 2024
- Published by Wiley in Journal of Turbomachinery
- Vol. 146 (10)
Action Mechanism of Film Extraction on Channel Impingement Cooling for Blade Leading Edge Using Large Eddy Simulation
Various internal cooling techniques combined with external film cooling are applied to cool gas turbine blades, and the coolant extraction can cause variations in internal flow structures and cooling effectiveness. Effects of film extraction under different film hole diameters and coolant mass flow ratio on heat transfer and flow characteristics of channel impingement cooling are presented using large eddy simulation (LES) in this article. The current work was undertaken based on turbine blade dimensions and turbine operating conditions. The results indicate that film extraction coupled with the curvature-induced instability dominates flow patterns and heat transfer in the channel impingement cooling structure with a film hole, especially in the bend region corresponding to the leading edge of turbine blades. Film coolant extraction can disrupt the streamwise counterrotating flow circulation pair. The latter is caused by the curvature-induced instability and is also the major driver of multilongitudinal vortices. The hole edge vortex generated by coolant bleed amplifies heat transfer at the leading edge, and the effect is more significant as the film hole diameter increases. Conversely, heat transfer coefficient downstream of the cooling channel decreases due to a reduction in cooling air. The increasing film bleed flow increases overall total pressure loss, while flow loss in the cooling channel decreases because of the weakened flow circulations and reduced coolant mass flow. This work provides an in-depth insight into the cooling performance of channel impingement cooling with film extraction, contributing to designing film cooling for turbine blades with multichannel wall jet cooling.
- 4 March 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 146 (5) , 1-37
Heat Transfer and Flow Characteristics of Channel Impingement Cooling Structure at Leading Edge Inside Turbine Blades Using Large Eddy Simulation
As a main part of multichannel wall jet cooling structure, channel impingement cooling is a cooling strategy of great concern at the leading edge inside of the turbine blade. In this paper, heat transfer and flow behavior in the channel impingement cooling structure are investigated by large eddy simulation (LES). The results imply that impingement created by curvature-induced centrifugal instabilities in the turning region of the cooling channel is dominated by a streamwise vortex system containing a counter-rotating Dean vortex, which presents high heat transfer streaks along the streamwise direction on the target wall. The intensely unsteady nature of the cooling jet induced by a lack of equilibrium between the pressure gradient and the centrifugal force is precisely captured herein by LES. An attaching-wall jet formed on the outer wall downstream of the cooling channel has highly three-dimensional characteristics not observed by Reynolds-averaged Navier–Stokes equations (RANS). Heat transfer augmentation on the target wall of the cooling channel is mainly due to the intensifying streamwise vortex system developing in the turning region as driven by the centrifugal force. This research work will provide a reference for the optimization and application of multichannel wall jet cooling for gas turbine blades.
- 4 March 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 146 (5) , 1-37
Heat Transfer and Flow Characteristics of Channel Impingement Cooling Structure at Leading Edge Inside Turbine Blades Using Large Eddy Simulation
As a main part of multichannel wall jet cooling structure, channel impingement cooling is a cooling strategy of great concern at the leading edge inside of the turbine blade. In this paper, heat transfer and flow behavior in the channel impingement cooling structure are investigated by large eddy simulation (LES). The results imply that impingement created by curvature-induced centrifugal instabilities in the turning region of the cooling channel is dominated by a streamwise vortex system containing a counter-rotating Dean vortex, which presents high heat transfer streaks along the streamwise direction on the target wall. The intensely unsteady nature of the cooling jet induced by a lack of equilibrium between the pressure gradient and the centrifugal force is precisely captured herein by LES. An attaching-wall jet formed on the outer wall downstream of the cooling channel has highly three-dimensional characteristics not observed by Reynolds-averaged Navier–Stokes equations (RANS). Heat transfer augmentation on the target wall of the cooling channel is mainly due to the intensifying streamwise vortex system developing in the turning region as driven by the centrifugal force. This research work will provide a reference for the optimization and application of multichannel wall jet cooling for gas turbine blades.
- 9 January 2023
- Published by Wiley in Journal of Turbomachinery
- Vol. 145 (6) , 1-33
Cooling and Flow Characteristics of Multi-Channel Wall Jet Structure With Film Holes at Blade Leading Edge
Efficient cooling is imperative for gas turbine blades that suffer from hot gas erosion. Cooling and flow characteristics of multi-channel wall jet structure combined with film holes for blade leading edge are numerically investigated through the Reynolds-averaged Navier–Stokes method in this paper. Several geometrical schemes with different rows and diameters of film holes were conducted, and the influences of the cooling air mass flow ratio of the first coolant supply cavity were also considered, which presented the detailed flow and cooling characteristics of wall jet and film composite cooling on conjugate heat transfer. The results implied that film extraction improves the overall cooling effectiveness compared with pure wall jet cooling. And the mainstream intrusion happens in some film holes at the bottom of blades, especially on the pressure side. The film-hole diameter can raise the mass flow ratio and enhance external thermal protection produced by cooling air, and it also affects the uniformity of film flow and the temperature gradient of some regions for turbine blades. Furthermore, the cooling performance and pressure loss are significantly influenced by the coolant mass flowrate of the first cooling air supply cavity. This study will offer a consultation for the design of film-hole structures for multi-channel wall jet cooling.
- 9 January 2023
- Published by Wiley in Journal of Turbomachinery
- Vol. 145 (6) , 1-33
Cooling and Flow Characteristics of Multi-Channel Wall Jet Structure With Film Holes at Blade Leading Edge
Efficient cooling is imperative for gas turbine blades that suffer from hot gas erosion. Cooling and flow characteristics of multi-channel wall jet structure combined with film holes for blade leading edge are numerically investigated through the Reynolds-averaged Navier–Stokes method in this paper. Several geometrical schemes with different rows and diameters of film holes were conducted, and the influences of the cooling air mass flow ratio of the first coolant supply cavity were also considered, which presented the detailed flow and cooling characteristics of wall jet and film composite cooling on conjugate heat transfer. The results implied that film extraction improves the overall cooling effectiveness compared with pure wall jet cooling. And the mainstream intrusion happens in some film holes at the bottom of blades, especially on the pressure side. The film-hole diameter can raise the mass flow ratio and enhance external thermal protection produced by cooling air, and it also affects the uniformity of film flow and the temperature gradient of some regions for turbine blades. Furthermore, the cooling performance and pressure loss are significantly influenced by the coolant mass flowrate of the first cooling air supply cavity. This study will offer a consultation for the design of film-hole structures for multi-channel wall jet cooling.
- Open Access
Cooling Characteristic of a Wall Jet for Suppressing Crossflow Effect under Conjugate Heat Transfer Condition
The leading edge is the critical portion for a gas turbine blade and is often insufficiently cooled due to the adverse effect of Crossflow in the cooling chamber. A novel internal cooling structure, wall jet cooling, can suppress Crossflow effect by changing the coolant flow direction. In this paper, the conjugate heat transfer and aerodynamic characteristics of blades with three different internal cooling structures, including impingement with a single row of jets, swirl cooling, and wall jet cooling, are investigated through RANS simulations. The results show that wall jet cooling combines the advantages of impingement cooling and swirl cooling, and has a 19–54% higher laterally-averaged overall cooling effectiveness than the conventional methods at different positions on the suction side. In the blade with wall jet cooling, the spent coolant at the leading edge is extracted away through the downstream channels so that the jet could accurately impinge the target surface without unnecessary mixing, and the high turbulence generated by the separation vortex enhances the heat transfer intensity. The Coriolis force induces the coolant air to adhere to the pressure side’s inner wall surface, preventing the jet from leaving the target surface. The parallel cooling channels eliminate the common Crossflow effect and make the flow distribution of the orifices more uniform. The trailing edge outlet reduces the entire cooling structure’s pressure to a low level, which means less penalty on power output and engine efficiency.
Open AccessCooling Characteristic of a Wall Jet for Suppressing Crossflow Effect under Conjugate Heat Transfer Condition
The leading edge is the critical portion for a gas turbine blade and is often insufficiently cooled due to the adverse effect of Crossflow in the cooling chamber. A novel internal cooling structure, wall jet cooling, can suppress Crossflow effect by changing the coolant flow direction. In this paper, the conjugate heat transfer and aerodynamic characteristics of blades with three different internal cooling structures, including impingement with a single row of jets, swirl cooling, and wall jet cooling, are investigated through RANS simulations. The results show that wall jet cooling combines the advantages of impingement cooling and swirl cooling, and has a 19–54% higher laterally-averaged overall cooling effectiveness than the conventional methods at different positions on the suction side. In the blade with wall jet cooling, the spent coolant at the leading edge is extracted away through the downstream channels so that the jet could accurately impinge the target surface without unnecessary mixing, and the high turbulence generated by the separation vortex enhances the heat transfer intensity. The Coriolis force induces the coolant air to adhere to the pressure side’s inner wall surface, preventing the jet from leaving the target surface. The parallel cooling channels eliminate the common Crossflow effect and make the flow distribution of the orifices more uniform. The trailing edge outlet reduces the entire cooling structure’s pressure to a low level, which means less penalty on power output and engine efficiency.