Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jelena Janković has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Kinetic Study of Silver Corrosion in Power Transformers Induced by Elemental Sulfur in Synthetic Ester and Comparison With Mineral Oil

    by Milica Ðukić, Jelena Lukić, Jelena Janković

    Over the years, mineral oils have been replaced by synthetic esters as environmentally friendly insulating fluids. A decade ago, it was assumed that the problem with corrosive sulfur was solely related to mineral oil, but recent cases have disproved this rigid opinion. The presence of elemental sulfur in synthetic ester insulating liquid increases the risk of failure of transformers due to silver corrosion. However, factors influencing formation of silver sulfide deposits are still not investigated. This paper presents the progress made in understanding the mechanism by which elemental sulfur reacts with silver in synthetic ester insulating liquids at temperatures ranging from 120 to 180 °C. The research aims to provide theoretical insight into the kinetics of this reaction. Quantitative analyses of the reaction, i.e. elemental sulfur content in the liquid are measured at defined times during the course of the reaction by gas chromatography with electron capture detector (GC-ECD). Results show that kinetics of the reaction between elemental sulfur and silver in synthetic ester as an insulating liquid, follow the first-order law. The study indicates that adsorption and the subsequent surface reaction, followed by diffusion through the silver sulfide layer, proceed more slowly and require more energy than the diffusion of elemental sulfur through the oil. The comparative analysis with mineral oils reveals that examined reaction takes place faster in synthetic ester insulating liquids, forcing urgent application of mitigation measures.

  • Open Access

    Kinetic Analysis of the Reaction of Silver with Elemental Sulfur in Mineral Insulating Oil

    by Dejan Kolarski, Jelena Lukić, Jelena Janković, Sandra Glišić

    Elemental sulfur (S8) reacts readily with silver, forming highly conductive silver sulfide on silver-coated components of on-load tap changers (OLTCs), forming a highly conductive silver sulfide film at the surface of an OLTC, which can lead to the failure of critical components in power transformers. This study investigates the reaction between metallic silver and elemental sulfur dissolved in mineral insulating oil across temperatures from 60 °C to 180 °C. The process involves three stages: the diffusion of sulfur through oil, surface reaction, and product diffusion. For low-viscosity oil, diffusion is not the limiting factor, and sulfur does not react immediately on the silver’s surface, suggesting possible adsorption or intermediate formation. A kinetic analysis revealed that the reaction follows first-order kinetics, with a change in mechanism above 150 °C. The reaction follows the Arrhenius equation in two separate regions: 60–150 °C and 150–180 °C. Activation energy was calculated as 23.67 kJ mol−1, and it can be concluded that the reaction is controlled by the diffusion of sulfur through mineral oil, and at higher temperatures (150 °C to 180 °C), the calculated activation energy is 160.69 kJ mol−1, which leads to the conclusion that the combined chemisorption and diffusion through a silver sulfide–oil interface becomes the new limiting factor.


  • Open Access

    Process for Simultaneous Removal of S8, DBDS, and PCBs From Mineral Insulating Oils

    by D. M. Kolarski, J. M. Lukic, J. U. Janković, Sandra Glisic, A. M. Orlović

    The presence of corrosive sulfur and polychlorinated biphenyls (PCBs) in mineral insulating oils poses significant challenge to the reliability of power transformers and presents serious environmental risks. Elemental sulfur (S8) and dibenzyl disulfide (DBDS) are well-known for causing the formation of metal sulfides on transformer components, leading to equipment failures, while PCBs present in insulating oils are persistent environmental pollutants with long-term health hazards. Current insulating oil purification techniques, including adsorbents, metal passivators and reagents, exhibit limited effectiveness, particularly if elemental sulfur is present in oil. This study introduces a novel reagent-based desulfurization process which uses copper deposited on iron particles dispersed in polyethylene glycol, for the complete removal of S8 from mineral insulating oil. The integration of S8 removal process with the KOH/PEG complex enables the simultaneous removal of S8, DBDS, and PCBs, with no residual metal particles detected in the oil following the treatment. Laboratory-scale experiments have shown the high efficiency of the developed process resulting in the improved physical-chemical and electrical properties of the oil, which was further verified on pilot scale unit and finally on the industrial scale process unit.

  • 3PINT innovative technologies as permanent solution to mitigate corrosive sulphur in power transformers

    by Jelena Lukić, Draginja Mihajlović, Jelena Janković, Valentina Vasović, Vladimir Ivančević, Dejan Kolarski, Neda Kovačević

    Focus of 3PINT project is to upgrade readiness level of the innovative technology for the removal of corrosive sulphur, PCB and aging product from transformer oils. Technology itself includes chemical conversion process to refine transformer oils in eco-friendly manner. Used technology is environmentally closed with no toxic emissions and waste released into environment. In addition, innovative solution for corroded silver-plated contacts cleaning, effectively removes silver sulphide deposits from OLTC contacts, ensuring long-term reliability and complete power transformer corrosive sulphur mitigation.

  • Open Access

    Kinetics of the reaction between elemental sulfur and silver in synthetic esters and comparison with mineral oils

    by Milica Đukić, Jelena Lukić, Jelena Janković, Dejan Kolarski

    For decades, the problem of corrosive sulfur was considered to be exclusively associated with mineral oils. However, recent cases from industry have disproved this assumption. The presence of elemental sulfur in insulating oil causes corrosion of silver contacts and consequently leads to power transformer failures. The aim of this study is to determine the kinetics of the reaction between elemental sulfur and silver in synthetic ester within the temperature range of 120–180 °C. The elemental sulfur content in the oil during the reaction is determined using gas chromatography with an electron capture detector (GC-ECD). The results show that the reaction between silver and elemental sulfur follows the first-order law. A comparative analysis of the examined reaction in synthetic ester and mineral oil shows that the reaction proceeds faster in synthetic ester.

  • Development of a New Method for the Assessment of Mineral Insulating Oil Corrosivity Against Silver

    by Jelena Jankovic, Jelena Lukic, Draginja Mihajlovic, Marc Foata, Barry Myburgh

    Corrosive sulfur compounds in mineral insulating oils can easily react with metal surfaces in power transformers and form deposits, which can further cause failures of the electrical equipment. Copper sulfide formation has been well studied over the last couple of decades. However, silver sulfide formation also requires attention, due to significant number of failures of on-load tap changers caused by silver corrosion reported worldwide from different utilities. The conventional silver corrosion tests (DIN 51353 and ASTM D1275-15) do not provide adequate assessment of oil corrosivity against silver, even if the oil contains dibenzyl disulfide (DBDS) and other reactive sulfur compounds (disulfides and mercaptans) in high concentrations. The new testing method for silver corrosion has been performed on a significant portion of oils containing DBDS, as major reactive sulfur compound, which remained “non-corrosive” following the ASTM D1275-15 silver strip test. The method was demonstrated on five oils from free-breathing power transformers in service, containing DBDS in a wide range of concentrations (from approx. 40 to 200 mg/kg of DBDS). The new method comprises of a modification to the ASTM D 1275-15 test set up, by introducing longer test duration times and continuous oxygen ingress, which was found to be the most crucial parameter for promoting the formation of silver sulfide deposits. This was confirmed by EDX results, showing an increased sulfur weight percentage on silver strip after the test. The application of the modified ASTM silver corrosion test will contribute to improving the assessment of sulfur corrosion risk.


  • Open Access

    Results of the GreenCleanS Project funded by the Science Fund of the Republic of Serbia

    by Dejan Kolarski, Jelena Lukić, Valentina Vasović, Jelena Janković, Draginja Mihajlović

    The project funded by the Science Fund of the Republic of Serbia, Development of Green Technology to Mitigate Power Transformer Failures Induced by Elemental Sulphur and Change Current Hazardous Practice in Transformer Oil Regeneration, under the acronym GreenCleanS focuses on developing a new technology for removing elemental sulphur molecule (S₈) from mineral insulating oils used in power transformers (PT) utilization an innovative low-temperature desulfurization process. The technology development includes experimental work at the laboratory scale and pilot scale level (technology readiness level, TRL 4), as well as the demonstration of the technology in an operational environment, involving the treatment of 3 tons of oil in a mobile desulfurization unit to achieve TRL 7. The implementation of this innovative technology will contribute to reducing the number of transformer failures caused by mineral oils containing S₈, a highly corrosive compound.

  • PROCEDURE FOR REMOVING ELEMENTAL SULFUR FROM THE OIL OF POWER TRANSFORMERS - REDUCING THE RISK OF POWER TRANSFORMERS FAILURES

    by Elektrotehnički Institut Nikola Tesla Univerzitet u Beogradu, Dejan Kolarski, Valentina Vasović, Jelena Janković, Draginja Mihajlović, Jovana Bošnjaković

    During the past years, there has been an increase in the number of power transformer failures worldwide linked by the presence of corrosive sulfur compounds in mineral insulating oil, leading to the formation of deposits of highly conductive copper sulfide or silver sulfide. In oils in operation, a highly reactive elemental sulfur, in a form of eight atom molecule of sulfur, S8, with a strong affinity for silver can be detected which present a significant threat to the contacts of the on load tap changer (OLTC). The high-temperature reactivation process of adsorbents during or after the regeneration process of mineral insulating oils leads to the contamination of insulating oil with elemental sulfur. The paper presents an innovative low-temperature process for the efficient removal of S8 from mineral insulating oil, based on the application of a small amount of iron particles coated with copper on its surface as a key component of the reagent mixture which is dispersed in polyethylene glycol. Intensive mixing of the reagent mixture with mineral insulating oil at temperatures below 100°C enables the complete removal of S8 from the oil. High process efficiency, the removal of S8 from the initial 15 mg/kg to levels below the detection limit, is achieved by using a small amount of the reagent mixture relative to the oil mass (<0.2 wt.%), in laboratory conditions and on a pilot scale experiments. Applying this process and subsequent treatment with adsorbents, insulating oils with improved physical, chemical and electrical characteristics are obtained, suitable for further use in power transformers. This procedure reduces potential environmental and economic risks associated with power transformer failures. The next phase will involve further process optimization and industrial plant implementation.

  • Open Access

    Isotherm, Thermodynamic and Kinetic Studies of Elemental Sulfur Removal from Mineral Insulating Oils Using Highly Selective Adsorbent

    by Jelena Jankovic, Jelena Lukic, Dejan Kolarski, Djordje Veljović, Željko Radovanović, Silvana Dimitrijević

    Elemental sulfur (S8) is a corrosive sulfur compound which was found to be extremely reactive to silver, causing intensive silver sulfide (Ag2S) deposition on on-load tap changer (OLTC) contacts in power transformers. A highly selective adsorbent (HSA), called Tesla’Ssorb, for the removal of S8 from mineral insulating oils was prepared from raw material (RM) using the novel procedure. In this study, the adsorption properties of HSA for the removal of S8 from the oil were determined. RM and HSA were characterized using various techniques, such as field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray (EDX), and X-ray diffraction (XRD). The performance of HSA was determined by adsorption equilibrium, thermodynamic, and kinetic study through batch experiments, at various temperatures and initial concentrations of S8. The obtained results were analyzed by Langmuir and Freundlich adsorption isotherms and it was found that equilibrium data were fitted better with the Langmuir isotherm model. The maximum adsorption capacity was 4.84 mg of S8/g of HSA at 353 K. Thermodynamic parameters, such as enthalpy (ΔH°), Gibbs free energy (ΔG°), and entropy (ΔS°), were calculated and it was found that the sorption process was spontaneous (ΔG° < 0) and endothermic in nature (ΔH° > 0). It was found that the adsorption of S8 follows pseudo-second-order kinetic model, and the activation energy indicated the activated chemisorption process.


  • Application of Highly Selective Adsorbent in the Removal of Elemental Sulfur and Other Corrosive Sulfur Compounds From Mineral Insulating Oils

    by Jelena Jankovic, Jelena Lukic, Jelena Planojevic, Dejan Kolarski, Djordje Janackovic

    The presence of corrosive sulfur in the oil increases the risks of power transformer failures. This is very pronounced in the case of the presence of elemental sulfur (S 8 ) in the oil a compound found to be highly reactive to metals, especially to silver at lower operating temperatures causing formation of conductive silver sulfide deposits on the contacts of on-load tap changers. Highly selective adsorbent (HSA) as new mesoporous material is synthesized in the novel procedure to be applied in the removal of corrosive sulfur compounds from the oil. The removal of corrosive sulfur compounds by HSA is obtained by chemical reaction, i.e., chemisorption. The procedure for the preparation of HSA consists of deposition of silver ions on the silicon dioxide support. Both compounds added in well-defined and optimal concentration range are necessary to produce adsorbent of high efficiency in the removal of S 8 and other corrosive sulfur compounds and to obtain good oil properties after treatment. HSA is characterized by nitrogen adsorption–desorption isotherms to define specific surface area, particle size distribution, and porosity. Since the efficiency of conventional adsorbents is found to be lowest in the case of elemental sulfur, among all corrosive sulfur compounds, the efficiency of HSA application in the removal of S 8 is verified on lab-scale system, pilot-scale system, and on-site oil treatment on 35-kV power transformer. Adsorption kinetic study is performed in order to better understand the mechanism of sorption process and potential rate-controlling steps. The pseudo-second-order model adequately fits the S 8 kinetic data confirming that chemisorption is the rate-limiting step.