Stig Storgaard Jakobsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stig Storgaard Jakobsen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kjeld Søballe
Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Maiken Stilling
Aarhus University Hospital
2 shared publications - Peter Bo Jørgensen
Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Bart L. Kaptein
Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
1 shared publication - Dovydas Vainorius
Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
1 shared publication - Inger Mechlenburg
Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
1 shared publication
Latest Publications
- Open Access
- 21 March 2022
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 93, 375–381
Polyethylene liner motion in dual-mobility hip prostheses: static and dynamic radiostereometry in 16 patients 1 year after operation
Background and purpose: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). Patients and methods: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER–FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. Results: Liner movement during modified FABER–FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12–46) and in liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median liner anteversion from 7° (−12 to 23) postoperatively to 10° (−3 to 16) at 1-year follow-up and inclination from 42° (35–66) postoperatively to 59° (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). Interpretation: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.
- 21 March 2022
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 93, 375–381
Open AccessPolyethylene liner motion in dual-mobility hip prostheses: static and dynamic radiostereometry in 16 patients 1 year after operation
Background and purpose: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). Patients and methods: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER–FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. Results: Liner movement during modified FABER–FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12–46) and in liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median liner anteversion from 7° (−12 to 23) postoperatively to 10° (−3 to 16) at 1-year follow-up and inclination from 42° (35–66) postoperatively to 59° (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). Interpretation: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.
- 3 February 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (2) , 1071-1080
Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up
Introduction The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. Material and method In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70–89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> − 1) and low (< − 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. Results At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was − 0.04° (CI 95% − 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% − 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). Conclusion The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.
- 3 February 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (2) , 1071-1080
Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up
Introduction The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. Material and method In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70–89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> − 1) and low (< − 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. Results At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was − 0.04° (CI 95% − 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% − 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). Conclusion The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.