Tian Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tian Xu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Lijian Shi
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225000, China
3 shared publications - Yao Chai
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225000, China
2 shared publications - Yuhang Jiang
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225000, China
2 shared publications - Beishuai Chen
Jiangsu Pumping Station Technology Co., Ltd. of South-to-North Water Diverslon Project, Yangzhou 225000, China
1 shared publication - Changxin Wu
Huai’an Institute of Hydraulic Survey and Design, Ltd., Huai’an 223001, China
1 shared publication - Fangping Tang
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225000, China
1 shared publication
Latest Publications
- Open Access
- 22 April 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 11 (5) , 895
Numerical Analysis of Energy Loss in Stall Zone for Full Tubular Pump Based on Entropy Generation Theory
As a low-head and non-drive pump, the head reduction and stall advance are the key factors that restrict the popularization and application of the full tubular pump (FTP). In this paper, the shear stress transport (SST) k-ω turbulence model is used for the numerical calculation of the FTP. Additionally, based on the entropy generation theory, the energy loss and main distribution zones of the FTP under all working conditions are analyzed, and the mechanism of inducing its stall advance is explored. By comparison, we found that there is little difference between the numerical simulation results and the model test. Turbulence entropy generation has a high proportion under small flow conditions, which is mainly reflected in the outlet flow separation zone of the suction surface of the impeller blade, the guide vane inlet zone where inlet deviation exists, and the trailing edge of the guide vane where the flow separation exists. Compared with the axial flow pump (AFP), when the flow rate decreases, the clearance reflow between the stator and rotor induces the deterioration of the flow at the impeller inlet, and the turbulent entropy generation in the impeller channel increases rapidly, making the FTP enter the stall zone ahead of time. The clearance backflow affects the flow pattern of the inlet pipe, making the turbulence entropy generation in the outlet area of the inlet pipe increase. The total entropy generation in the stator–rotor region is little affected by the pump flow conditions, and it is mainly affected by different stator–rotor backflow clearance dimensions. This study can provide a reference for exploring the energy loss of the FTP and revealing its stall characteristics.
- 22 April 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 11 (5) , 895
Open AccessNumerical Analysis of Energy Loss in Stall Zone for Full Tubular Pump Based on Entropy Generation Theory
As a low-head and non-drive pump, the head reduction and stall advance are the key factors that restrict the popularization and application of the full tubular pump (FTP). In this paper, the shear stress transport (SST) k-ω turbulence model is used for the numerical calculation of the FTP. Additionally, based on the entropy generation theory, the energy loss and main distribution zones of the FTP under all working conditions are analyzed, and the mechanism of inducing its stall advance is explored. By comparison, we found that there is little difference between the numerical simulation results and the model test. Turbulence entropy generation has a high proportion under small flow conditions, which is mainly reflected in the outlet flow separation zone of the suction surface of the impeller blade, the guide vane inlet zone where inlet deviation exists, and the trailing edge of the guide vane where the flow separation exists. Compared with the axial flow pump (AFP), when the flow rate decreases, the clearance reflow between the stator and rotor induces the deterioration of the flow at the impeller inlet, and the turbulent entropy generation in the impeller channel increases rapidly, making the FTP enter the stall zone ahead of time. The clearance backflow affects the flow pattern of the inlet pipe, making the turbulence entropy generation in the outlet area of the inlet pipe increase. The total entropy generation in the stator–rotor region is little affected by the pump flow conditions, and it is mainly affected by different stator–rotor backflow clearance dimensions. This study can provide a reference for exploring the energy loss of the FTP and revealing its stall characteristics.
- Open Access
Flow Characteristics and Optimization Design of the Stator–Rotor Cavity of the Full Tubular Pump
The full tubular pump device is taken as the research object in this article. This research method adopts the numerical simulation technology based on the SST (Shear-Stress-Transport) k-ω turbulence model to explore the internal flow characteristics of the stator–rotor cavity of the full tubular pump and optimize the stator–rotor clearance structure. The research shows that under the design conditions, compared with the axial flow pump, the torque increases by 47.91 N·m at the stator–rotor cavity structure and the efficiency decreases by about 20%. The torque at the rotor clearance of the full tubular pump accounts for about 50% of the torque at the rotor. Since there is a large area of backflow on both sides of the cavity, and there is a vortex structure on the inlet side of the cavity, it shows that the rotor structure and its area greatly affect the operating efficiency of the pump device. With the reduction in the rotor force area, the clearance length, and the outer diameter of the disc, the operating efficiency of the pump device gradually increases. Under the design conditions, the optimized model has a maximum efficiency increase of 14.04% and the torque at the cavity rotor is reduced by 39.25 N·m. The results show that the operating efficiency of the full tubular pump is closely related to its rotor structure area, and the force area of the rotor structure needs to be controlled in the actual design process.
Open AccessFlow Characteristics and Optimization Design of the Stator–Rotor Cavity of the Full Tubular Pump
The full tubular pump device is taken as the research object in this article. This research method adopts the numerical simulation technology based on the SST (Shear-Stress-Transport) k-ω turbulence model to explore the internal flow characteristics of the stator–rotor cavity of the full tubular pump and optimize the stator–rotor clearance structure. The research shows that under the design conditions, compared with the axial flow pump, the torque increases by 47.91 N·m at the stator–rotor cavity structure and the efficiency decreases by about 20%. The torque at the rotor clearance of the full tubular pump accounts for about 50% of the torque at the rotor. Since there is a large area of backflow on both sides of the cavity, and there is a vortex structure on the inlet side of the cavity, it shows that the rotor structure and its area greatly affect the operating efficiency of the pump device. With the reduction in the rotor force area, the clearance length, and the outer diameter of the disc, the operating efficiency of the pump device gradually increases. Under the design conditions, the optimized model has a maximum efficiency increase of 14.04% and the torque at the cavity rotor is reduced by 39.25 N·m. The results show that the operating efficiency of the full tubular pump is closely related to its rotor structure area, and the force area of the rotor structure needs to be controlled in the actual design process.
- Open Access
Influence of Blade Angle Deviation on the Hydraulic Performance and Structural Characteristics of S-Type Front Shaft Extension Tubular Pump Device
When the axial-flow pump is running, the blade angle is not fully adjusted or there are errors in the manufacture of the blades, which will lead to inconsistent blade placement angles during operation, and which will reduce the efficiency of the axial-flow pump. This paper uses the research methods of numerical simulation and model experiments to analyze the hydraulic performance and impeller structure characteristics of each flow components under different schemes when the angles of each blade of the S-type front shaft extension tubular pump device are inconsistent. The research phenomenon is that the guide vane greatly recovers the flow velocity circulation at the impeller outlet, reduces the hydraulic loss of guide vane, and widens the best efficiency range with an increase in guide vane blade angle. When the blade angle deviation occurs, the flow field of each blade channel affects each other, and the maximum decrease in the best efficiency is up to 7.78%, mainly due to the increased hydraulic loss in the outlet channel. The blade angle deviation will also affect the maximum equivalent stress and maximum deformation of the impeller, which is more obvious in large flow conditions. Inconsistent blade angles seriously affect the operating efficiency of the water pump and water pump device, and make the structural characteristics of the impeller worse.
Open AccessInfluence of Blade Angle Deviation on the Hydraulic Performance and Structural Characteristics of S-Type Front Shaft Extension Tubular Pump Device
When the axial-flow pump is running, the blade angle is not fully adjusted or there are errors in the manufacture of the blades, which will lead to inconsistent blade placement angles during operation, and which will reduce the efficiency of the axial-flow pump. This paper uses the research methods of numerical simulation and model experiments to analyze the hydraulic performance and impeller structure characteristics of each flow components under different schemes when the angles of each blade of the S-type front shaft extension tubular pump device are inconsistent. The research phenomenon is that the guide vane greatly recovers the flow velocity circulation at the impeller outlet, reduces the hydraulic loss of guide vane, and widens the best efficiency range with an increase in guide vane blade angle. When the blade angle deviation occurs, the flow field of each blade channel affects each other, and the maximum decrease in the best efficiency is up to 7.78%, mainly due to the increased hydraulic loss in the outlet channel. The blade angle deviation will also affect the maximum equivalent stress and maximum deformation of the impeller, which is more obvious in large flow conditions. Inconsistent blade angles seriously affect the operating efficiency of the water pump and water pump device, and make the structural characteristics of the impeller worse.