Yao Chai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yao Chai has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Lijian Shi
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225000, China
4 shared publications - Tian Xu
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225000, China
2 shared publications - Yuhang Jiang
College of Hydraulic Science and Engineering, Yangzhou University 1 , Yangzhou 225000, China
2 shared publications - Beishuai Chen
Jiangsu Pumping Station Technology Co., Ltd. of South-to-North Water Diverslon Project, Yangzhou 225000, China
1 shared publication - Bin Xie
Jiangsu Water Source Company Ltd. of the Eastern Route of the South-to-North Water Diversion Project, Nanjing 210008, China
1 shared publication Boyang Yan
Huai'an Institute of Hydraulic Survey and Design, Ltd 2 ., Huai'an 223001, China
1 shared publication
Latest Publications
- Open Access
Numerical Simulation and Model Test on Pressure Fluctuation and Structural Characteristics of Lightweight Axial Flow Pump
In order to explore the relationship between the hydraulic performance, pressure pulsation, and structural characteristics of lightweight axial flow pumps, this paper takes the axial flow pump as the research object and analyzes pressure pulsation and structural characteristics by changing the blade length and thickness to realize the lightweight design of the axial flow pump impeller. Compared with the initial scheme (Scheme 1), the mass of the impeller is reduced by 17.2% (Scheme 2) and 29.9% (Scheme 3), respectively. The lightweight axial flow pump (Scheme 2 and Scheme 3) has a lower pressure pulsation amplitude at the impeller outlet monitoring point under large flow conditions. After the lightweight design of the axial flow pump impeller, the blade becomes shorter, the mass becomes lighter, and the cavitation performance will become worse. The maximum equivalent stress of Scheme 2 and Scheme 3 is increased by 2.8% and 31.9%, respectively, compared to Scheme 1. The maximum deformation of Scheme 3 increased by 27% compared to Scheme 1. This research can provide guidance for the lightweight optimization design of the axial flow pump.
Open AccessNumerical Simulation and Model Test on Pressure Fluctuation and Structural Characteristics of Lightweight Axial Flow Pump
In order to explore the relationship between the hydraulic performance, pressure pulsation, and structural characteristics of lightweight axial flow pumps, this paper takes the axial flow pump as the research object and analyzes pressure pulsation and structural characteristics by changing the blade length and thickness to realize the lightweight design of the axial flow pump impeller. Compared with the initial scheme (Scheme 1), the mass of the impeller is reduced by 17.2% (Scheme 2) and 29.9% (Scheme 3), respectively. The lightweight axial flow pump (Scheme 2 and Scheme 3) has a lower pressure pulsation amplitude at the impeller outlet monitoring point under large flow conditions. After the lightweight design of the axial flow pump impeller, the blade becomes shorter, the mass becomes lighter, and the cavitation performance will become worse. The maximum equivalent stress of Scheme 2 and Scheme 3 is increased by 2.8% and 31.9%, respectively, compared to Scheme 1. The maximum deformation of Scheme 3 increased by 27% compared to Scheme 1. This research can provide guidance for the lightweight optimization design of the axial flow pump.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (1)
Numerical simulation and model test of the influence of guide vane angle on the performance of axial flow pump
The axial flow pump is a low-head pump widely used in farmland irrigation and water transfer engineering in plain areas. To study the effects of different guide vane rotation angles and inlet angles on the performance of axial flow pumps, based on the initial scheme of the guide vane, the efficiency of the axial flow pump is expected to be improved by adjusting the guide vane rotation angles and changing the inlet angles of the guide vane. This paper uses Computational Fluid Dynamics numerically to simulate and calculate the performance of axial flow pumps under different guide vane rotation angles and inlet angles. The results show that the influence of different guide vane rotation angles and inlet angles on the performance of the axial flow pump is reflected in the operating conditions of large-discharge conditions. Adjusting different guide vane rotation angles can significantly improve the efficiency of axial flow pumps. Moreover, the high-efficiency area of the axial flow pump is expanded nearly two times with the increase in the guide vane rotation angles under large-discharge conditions. At the same time, under the design condition, the highest efficiency of the axial flow pump is 87.69% under scheme V. However, under the linear change of the inlet angle of the guide vane, the highest efficiency of the axial flow pump can reach 87.71%. Finally, the model test verifies the reliability of the numerical simulation, and the research results are beneficial for improving the efficiency of the axial flow pump.
- 1 January 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (1)
Open AccessNumerical simulation and model test of the influence of guide vane angle on the performance of axial flow pump
The axial flow pump is a low-head pump widely used in farmland irrigation and water transfer engineering in plain areas. To study the effects of different guide vane rotation angles and inlet angles on the performance of axial flow pumps, based on the initial scheme of the guide vane, the efficiency of the axial flow pump is expected to be improved by adjusting the guide vane rotation angles and changing the inlet angles of the guide vane. This paper uses Computational Fluid Dynamics numerically to simulate and calculate the performance of axial flow pumps under different guide vane rotation angles and inlet angles. The results show that the influence of different guide vane rotation angles and inlet angles on the performance of the axial flow pump is reflected in the operating conditions of large-discharge conditions. Adjusting different guide vane rotation angles can significantly improve the efficiency of axial flow pumps. Moreover, the high-efficiency area of the axial flow pump is expanded nearly two times with the increase in the guide vane rotation angles under large-discharge conditions. At the same time, under the design condition, the highest efficiency of the axial flow pump is 87.69% under scheme V. However, under the linear change of the inlet angle of the guide vane, the highest efficiency of the axial flow pump can reach 87.71%. Finally, the model test verifies the reliability of the numerical simulation, and the research results are beneficial for improving the efficiency of the axial flow pump.
- Open Access
Flow Characteristics and Optimization Design of the Stator–Rotor Cavity of the Full Tubular Pump
The full tubular pump device is taken as the research object in this article. This research method adopts the numerical simulation technology based on the SST (Shear-Stress-Transport) k-ω turbulence model to explore the internal flow characteristics of the stator–rotor cavity of the full tubular pump and optimize the stator–rotor clearance structure. The research shows that under the design conditions, compared with the axial flow pump, the torque increases by 47.91 N·m at the stator–rotor cavity structure and the efficiency decreases by about 20%. The torque at the rotor clearance of the full tubular pump accounts for about 50% of the torque at the rotor. Since there is a large area of backflow on both sides of the cavity, and there is a vortex structure on the inlet side of the cavity, it shows that the rotor structure and its area greatly affect the operating efficiency of the pump device. With the reduction in the rotor force area, the clearance length, and the outer diameter of the disc, the operating efficiency of the pump device gradually increases. Under the design conditions, the optimized model has a maximum efficiency increase of 14.04% and the torque at the cavity rotor is reduced by 39.25 N·m. The results show that the operating efficiency of the full tubular pump is closely related to its rotor structure area, and the force area of the rotor structure needs to be controlled in the actual design process.
Open AccessFlow Characteristics and Optimization Design of the Stator–Rotor Cavity of the Full Tubular Pump
The full tubular pump device is taken as the research object in this article. This research method adopts the numerical simulation technology based on the SST (Shear-Stress-Transport) k-ω turbulence model to explore the internal flow characteristics of the stator–rotor cavity of the full tubular pump and optimize the stator–rotor clearance structure. The research shows that under the design conditions, compared with the axial flow pump, the torque increases by 47.91 N·m at the stator–rotor cavity structure and the efficiency decreases by about 20%. The torque at the rotor clearance of the full tubular pump accounts for about 50% of the torque at the rotor. Since there is a large area of backflow on both sides of the cavity, and there is a vortex structure on the inlet side of the cavity, it shows that the rotor structure and its area greatly affect the operating efficiency of the pump device. With the reduction in the rotor force area, the clearance length, and the outer diameter of the disc, the operating efficiency of the pump device gradually increases. Under the design conditions, the optimized model has a maximum efficiency increase of 14.04% and the torque at the cavity rotor is reduced by 39.25 N·m. The results show that the operating efficiency of the full tubular pump is closely related to its rotor structure area, and the force area of the rotor structure needs to be controlled in the actual design process.
- Open Access
Influence of Blade Angle Deviation on the Hydraulic Performance and Structural Characteristics of S-Type Front Shaft Extension Tubular Pump Device
When the axial-flow pump is running, the blade angle is not fully adjusted or there are errors in the manufacture of the blades, which will lead to inconsistent blade placement angles during operation, and which will reduce the efficiency of the axial-flow pump. This paper uses the research methods of numerical simulation and model experiments to analyze the hydraulic performance and impeller structure characteristics of each flow components under different schemes when the angles of each blade of the S-type front shaft extension tubular pump device are inconsistent. The research phenomenon is that the guide vane greatly recovers the flow velocity circulation at the impeller outlet, reduces the hydraulic loss of guide vane, and widens the best efficiency range with an increase in guide vane blade angle. When the blade angle deviation occurs, the flow field of each blade channel affects each other, and the maximum decrease in the best efficiency is up to 7.78%, mainly due to the increased hydraulic loss in the outlet channel. The blade angle deviation will also affect the maximum equivalent stress and maximum deformation of the impeller, which is more obvious in large flow conditions. Inconsistent blade angles seriously affect the operating efficiency of the water pump and water pump device, and make the structural characteristics of the impeller worse.
Open AccessInfluence of Blade Angle Deviation on the Hydraulic Performance and Structural Characteristics of S-Type Front Shaft Extension Tubular Pump Device
When the axial-flow pump is running, the blade angle is not fully adjusted or there are errors in the manufacture of the blades, which will lead to inconsistent blade placement angles during operation, and which will reduce the efficiency of the axial-flow pump. This paper uses the research methods of numerical simulation and model experiments to analyze the hydraulic performance and impeller structure characteristics of each flow components under different schemes when the angles of each blade of the S-type front shaft extension tubular pump device are inconsistent. The research phenomenon is that the guide vane greatly recovers the flow velocity circulation at the impeller outlet, reduces the hydraulic loss of guide vane, and widens the best efficiency range with an increase in guide vane blade angle. When the blade angle deviation occurs, the flow field of each blade channel affects each other, and the maximum decrease in the best efficiency is up to 7.78%, mainly due to the increased hydraulic loss in the outlet channel. The blade angle deviation will also affect the maximum equivalent stress and maximum deformation of the impeller, which is more obvious in large flow conditions. Inconsistent blade angles seriously affect the operating efficiency of the water pump and water pump device, and make the structural characteristics of the impeller worse.