Yi Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yi Lu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhou
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
10 shared publications - Qingyun Chang
Qingdao University
5 shared publications - Yijun Zhang
School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, China
5 shared publications - Siyuan Jiang
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo, China
4 shared publications - Wenjing Fang
School of Electronics, Electrical Engineering, and Control, Qilu University of Technology, Jinan, China
3 shared publications - Hongjun Shi
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications
Latest Publications
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A Fault Diagnosis and Fault-Tolerant Control Method for Open-Circuit Fault of Excitation Winding Converter in DSEM Drive System
This paper proposes a fault location and fault-tolerant control method for the open-circuit fault of the excitation winding converter in the doubly salient electromagnetic motor (DSEM) drive system. Firstly, by rearranging the placement of the excitation current sensor and analyzing the change characteristics of the sampled current values before and after the excitation winding converter open-circuit fault, the faulty switch is quickly located. Then, fault-tolerant control strategies for the armature winding and excitation winding converter are designed for open-circuit faults in the excitation winding converter switches at different locations. This ensures that the output torque of the DSEM remains unchanged before and after fault-tolerant control, thus guaranteeing smooth motor operation. Simultaneously, the switching moment of the armature winding converter control strategy is optimized after the occurrence of the excitation winding converter open-circuit fault, in order to prevent the motor from outputting negative torque during the switching process. The proposed method can rapidly locate the faulty switch in the excitation winding converter without the need for additional sensors. It ensures that the motor maintains a consistent output torque before and after fault-tolerant operation, thereby guaranteeing the load-carrying capability of the motor. Finally, experiments conducted on a 12/8 three-phase DSEM verify the effectiveness and practicality of the proposed method.
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A Fault Diagnosis and Fault-Tolerant Control Method for Open-Circuit Fault of Excitation Winding Converter in DSEM Drive System
This paper proposes a fault location and fault-tolerant control method for the open-circuit fault of the excitation winding converter in the doubly salient electromagnetic motor (DSEM) drive system. Firstly, by rearranging the placement of the excitation current sensor and analyzing the change characteristics of the sampled current values before and after the excitation winding converter open-circuit fault, the faulty switch is quickly located. Then, fault-tolerant control strategies for the armature winding and excitation winding converter are designed for open-circuit faults in the excitation winding converter switches at different locations. This ensures that the output torque of the DSEM remains unchanged before and after fault-tolerant control, thus guaranteeing smooth motor operation. Simultaneously, the switching moment of the armature winding converter control strategy is optimized after the occurrence of the excitation winding converter open-circuit fault, in order to prevent the motor from outputting negative torque during the switching process. The proposed method can rapidly locate the faulty switch in the excitation winding converter without the need for additional sensors. It ensures that the motor maintains a consistent output torque before and after fault-tolerant operation, thereby guaranteeing the load-carrying capability of the motor. Finally, experiments conducted on a 12/8 three-phase DSEM verify the effectiveness and practicality of the proposed method.
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (1) , 812-821
A Novel Small Capacitor DSEM Drive System With Bus Voltage Ripple Suppression Effect
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (1) , 812-821
A Novel Small Capacitor DSEM Drive System With Bus Voltage Ripple Suppression Effect
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 355-366
An Online Estimation Method for DC-Link Capacitor in Doubly Salient Electromagnetic Motor Drive System
As a key component of the motor drive system, the dc-link capacitor has a significant impact on the system reliability. Therefore, it is of great significance to monitor the health status of the capacitor to assist the drive system in achieving preventive maintenance. This article proposes an online estimation method for dc-link capacitor in doubly salient electromagnetic motor (DSEM) drive system with small dc-link capacitance. By utilizing the characteristic that energy flows back from the motor to the bus during the commutation process, causing fluctuations in dc-link capacitor voltage, this method estimates the dc-link capacitance value based on the relationship among the motor phase current, dc-link capacitor voltage, and capacitance value. The proposed method requires no signal injection or the use of additional sensors, does not affect the normal operation of the motor, and offers high-estimation accuracy. The experimental results verify the effectiveness and practicality of the proposed dc-link capacitor estimation method.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 355-366
An Online Estimation Method for DC-Link Capacitor in Doubly Salient Electromagnetic Motor Drive System
As a key component of the motor drive system, the dc-link capacitor has a significant impact on the system reliability. Therefore, it is of great significance to monitor the health status of the capacitor to assist the drive system in achieving preventive maintenance. This article proposes an online estimation method for dc-link capacitor in doubly salient electromagnetic motor (DSEM) drive system with small dc-link capacitance. By utilizing the characteristic that energy flows back from the motor to the bus during the commutation process, causing fluctuations in dc-link capacitor voltage, this method estimates the dc-link capacitance value based on the relationship among the motor phase current, dc-link capacitor voltage, and capacitance value. The proposed method requires no signal injection or the use of additional sensors, does not affect the normal operation of the motor, and offers high-estimation accuracy. The experimental results verify the effectiveness and practicality of the proposed dc-link capacitor estimation method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 5646-5657
Research on Gain Fault Diagnosis of Current Sensor for Doubly Salient Electromagnetic Motor at Standstill
Fault diagnosis of current sensor is the key technology to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. In some occasions, such as initial position estimation of position sensorless, the motor is at standstill. However, there is no method addressing the fault diagnosis of current sensor for DSEM at standstill. To solve this problem, three methods are proposed to realize gain fault diagnosis of current sensor for DSEM at standstill in this article. One method is realized by detecting excitation current during excitation field building, and the other two are realized by detecting phase currents during the injection of specific current pulses. Then, there is a comparison of three fault diagnosis methods. The proposed method does not require the values of motor parameters, and it can be used either as part of an initial debugging or periodic testing of the system, which can also improve the reliability of initial position estimation to avoid startup failure of motor. Finally, the experimental results validate the effectiveness of the proposed method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 5646-5657
Research on Gain Fault Diagnosis of Current Sensor for Doubly Salient Electromagnetic Motor at Standstill
Fault diagnosis of current sensor is the key technology to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. In some occasions, such as initial position estimation of position sensorless, the motor is at standstill. However, there is no method addressing the fault diagnosis of current sensor for DSEM at standstill. To solve this problem, three methods are proposed to realize gain fault diagnosis of current sensor for DSEM at standstill in this article. One method is realized by detecting excitation current during excitation field building, and the other two are realized by detecting phase currents during the injection of specific current pulses. Then, there is a comparison of three fault diagnosis methods. The proposed method does not require the values of motor parameters, and it can be used either as part of an initial debugging or periodic testing of the system, which can also improve the reliability of initial position estimation to avoid startup failure of motor. Finally, the experimental results validate the effectiveness of the proposed method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (3) , 4324-4334
A Novel Doubly Salient Electromagnetic Motor Drive System With Small Bus Capacitor
This article proposes a small capacitor drive system for doubly salient electromagnetic motor (DSEM), including the drive circuit and its corresponding control strategy. By taking advantage of the characteristic that the inductor current cannot change abruptly, the system further utilizes AC source to charge the bus capacitor, thereby increasing the maximum voltage of the bus capacitor. Additionally, a bus switch control strategy suitable for this circuit is proposed to reduce the discharge time and energy required by the bus capacitor, thus reducing the required bus capacitance of the system. Compared to the traditional motor drive systems, the proposed system allows for the use of film capacitors instead of electrolytic capacitors, resulting in a reduced system volume and improved reliability and power density. Moreover, compared to the existing researches, the proposed system can more fully utilize the AC source to charge the bus capacitor, thereby improving the efficiency of the AC source, and simultaneously enhancing the power quality of the AC source. The experiments on a 12/8-pole DSEM validate the correctness and feasibility of the proposed system.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (3) , 4324-4334
A Novel Doubly Salient Electromagnetic Motor Drive System With Small Bus Capacitor
This article proposes a small capacitor drive system for doubly salient electromagnetic motor (DSEM), including the drive circuit and its corresponding control strategy. By taking advantage of the characteristic that the inductor current cannot change abruptly, the system further utilizes AC source to charge the bus capacitor, thereby increasing the maximum voltage of the bus capacitor. Additionally, a bus switch control strategy suitable for this circuit is proposed to reduce the discharge time and energy required by the bus capacitor, thus reducing the required bus capacitance of the system. Compared to the traditional motor drive systems, the proposed system allows for the use of film capacitors instead of electrolytic capacitors, resulting in a reduced system volume and improved reliability and power density. Moreover, compared to the existing researches, the proposed system can more fully utilize the AC source to charge the bus capacitor, thereby improving the efficiency of the AC source, and simultaneously enhancing the power quality of the AC source. The experiments on a 12/8-pole DSEM validate the correctness and feasibility of the proposed system.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 1357-1367
Midpoint Voltage of Bridge Arm Based Fault Diagnosis Method of Inverter and Phase Winding for DSEM
In the motor drive system, there are the same fault characteristics for the open circuit (OC) fault of phase winding (OCFOPW) and the two OC fault types of power switch (OCFTOPS). However, there is no method addressing the diagnosis of both OCFOPW and OCFTOPS. In order to solve this problem, this article proposes a fault diagnosis method of inverter and phase winding for doubly salient electromagnetic motor (DSEM) based on the midpoint voltage of bridge arm. First, based on unidirectional conduction of diode and the variation characteristics of back electromotive force (EMF), fault diagnosis is realized by constructing a forward voltage on the antiparallel diode. Then, a voltage threshold is set to eliminate misdiagnosis caused by the conduction voltage drop on the device, and the variation rate of excitation current is varied to ensure effective diagnosis in the case that the back EMF is less than voltage threshold. Finally, the experiments on a 12/8-pole DSEM validate the effectiveness of the proposed method.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 1357-1367
Midpoint Voltage of Bridge Arm Based Fault Diagnosis Method of Inverter and Phase Winding for DSEM
In the motor drive system, there are the same fault characteristics for the open circuit (OC) fault of phase winding (OCFOPW) and the two OC fault types of power switch (OCFTOPS). However, there is no method addressing the diagnosis of both OCFOPW and OCFTOPS. In order to solve this problem, this article proposes a fault diagnosis method of inverter and phase winding for doubly salient electromagnetic motor (DSEM) based on the midpoint voltage of bridge arm. First, based on unidirectional conduction of diode and the variation characteristics of back electromotive force (EMF), fault diagnosis is realized by constructing a forward voltage on the antiparallel diode. Then, a voltage threshold is set to eliminate misdiagnosis caused by the conduction voltage drop on the device, and the variation rate of excitation current is varied to ensure effective diagnosis in the case that the back EMF is less than voltage threshold. Finally, the experiments on a 12/8-pole DSEM validate the effectiveness of the proposed method.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 745-755
DC Bus Voltage Ripple Suppression Strategy for DSEM Drive System With Small DC-Link Capacitance
In order to absorb the energy flowing back to the dc bus during the motor commutation process and stabilize the dc bus voltage, it is common practice to connect large electrolytic capacitors in parallel with the dc bus in a doubly salient electromagnetic motor (DSEM) drive system. However, electrolytic capacitor is one of the most failure-prone components in the drive system due to its disadvantages of large size and short lifespan. This article proposes a novel control strategy for DSEM drive system. It effectively reduces the energy flowing back to the dc bus during the commutation process by introducing an advanced angle and modifying the conduction logic of the switches within a specific operating range, thereby ensuring the dc bus voltage ripple remains within the rated range. By employing the proposed control strategy, film capacitors can be used instead of electrolytic capacitors or even without bus capacitors, reducing the volume and cost of the drive system while improving its reliability and power density. The experimental results indicate that compared with the conventional control strategy, the proposed control strategy can reduce the voltage ripple and reduce the motor torque ripple.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 745-755
DC Bus Voltage Ripple Suppression Strategy for DSEM Drive System With Small DC-Link Capacitance
In order to absorb the energy flowing back to the dc bus during the motor commutation process and stabilize the dc bus voltage, it is common practice to connect large electrolytic capacitors in parallel with the dc bus in a doubly salient electromagnetic motor (DSEM) drive system. However, electrolytic capacitor is one of the most failure-prone components in the drive system due to its disadvantages of large size and short lifespan. This article proposes a novel control strategy for DSEM drive system. It effectively reduces the energy flowing back to the dc bus during the commutation process by introducing an advanced angle and modifying the conduction logic of the switches within a specific operating range, thereby ensuring the dc bus voltage ripple remains within the rated range. By employing the proposed control strategy, film capacitors can be used instead of electrolytic capacitors or even without bus capacitors, reducing the volume and cost of the drive system while improving its reliability and power density. The experimental results indicate that compared with the conventional control strategy, the proposed control strategy can reduce the voltage ripple and reduce the motor torque ripple.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8572-8584
Position Signal and Nonconduction Phase Current Based Fault Diagnosis Method of Position Sensor for Doubly Salient Electromagnetic Motor
Reliable rotor position information is essential for accurate commutation control of motor drive system. Traditionally, hall sensors have been widely used to obtain rotor position information. The fault of position sensor will lead to the confusion of the commutation logic, which will reduce the output torque of the motor and even fail to operate normally. Therefore, fault diagnosis of position sensor is the key technology to improve the reliability of the system. In this article, a fault diagnosis method of position sensor is proposed for doubly salient electromagnetic motor (DSEM) drive system, which only needs the existing position signals, the driving signals of switch, and the nonconduction phase current. Compared with the existing method, the proposed method does not require additional hardware and complex calculation, can realize the fault diagnosis of single, two and three position sensors, and is not influenced by the variation of speed and load. Besides, the time of error commutation for the proposed method is less than 1/3 electrical angle period, which is helpful to switch the fault-tolerant strategy in time and minimize the damage to the system caused by the fault. In order to verify the effectiveness of the proposed method, experiments are carried out on a 12/8 pole DSEM equipped with three hall position sensors. The experimental results under both steady and dynamic conditions show that the proposed method can quickly realize fault location.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8572-8584
Position Signal and Nonconduction Phase Current Based Fault Diagnosis Method of Position Sensor for Doubly Salient Electromagnetic Motor
Reliable rotor position information is essential for accurate commutation control of motor drive system. Traditionally, hall sensors have been widely used to obtain rotor position information. The fault of position sensor will lead to the confusion of the commutation logic, which will reduce the output torque of the motor and even fail to operate normally. Therefore, fault diagnosis of position sensor is the key technology to improve the reliability of the system. In this article, a fault diagnosis method of position sensor is proposed for doubly salient electromagnetic motor (DSEM) drive system, which only needs the existing position signals, the driving signals of switch, and the nonconduction phase current. Compared with the existing method, the proposed method does not require additional hardware and complex calculation, can realize the fault diagnosis of single, two and three position sensors, and is not influenced by the variation of speed and load. Besides, the time of error commutation for the proposed method is less than 1/3 electrical angle period, which is helpful to switch the fault-tolerant strategy in time and minimize the damage to the system caused by the fault. In order to verify the effectiveness of the proposed method, experiments are carried out on a 12/8 pole DSEM equipped with three hall position sensors. The experimental results under both steady and dynamic conditions show that the proposed method can quickly realize fault location.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (3) , 2626-2638
Copper Loss Optimization Strategy of Fault-Tolerant Operation for Doubly Salient Electromagnetic Generator Under Excitation Loss
The excitation loss of doubly salient electromagnetic generator (DSEG) can be caused by the fault in the excitation winding due to aging, overheating, external force impacts, as well as the fault in the excitation power converter due to reasons such as over-current and reverse voltage shocks, which makes the system exhibit abnormal operation. Consequently, a fault-tolerant power generation (FTPG) strategy is proposed for the DSEG system under excitation loss, which can enhance the DSEG’s fault-tolerant capability and mitigate the copper loss. First, this paper analyzes the fundamental principles of normal power generation in DSEG, establishes its mathematical model under excitation loss, and investigates the fault-tolerant control strategy. Subsequently, this paper analyzes the mechanism behind the high copper loss issue in implementing the positive and negative excitation angle control (PNEAC) strategy during the fault-tolerant operation of the DSEG under excitation loss. Furthermore, a positive and negative current given control (PNCGC) strategy with an advanced angle is proposed for FTPG, to optimize copper loss of DSEG under excitation loss. According to the mentioned hypothesis, some experiments are performed on an 18/12 pole DSEG system to demonstrate the feasibility and effectiveness of the proposed strategy.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (3) , 2626-2638
Copper Loss Optimization Strategy of Fault-Tolerant Operation for Doubly Salient Electromagnetic Generator Under Excitation Loss
The excitation loss of doubly salient electromagnetic generator (DSEG) can be caused by the fault in the excitation winding due to aging, overheating, external force impacts, as well as the fault in the excitation power converter due to reasons such as over-current and reverse voltage shocks, which makes the system exhibit abnormal operation. Consequently, a fault-tolerant power generation (FTPG) strategy is proposed for the DSEG system under excitation loss, which can enhance the DSEG’s fault-tolerant capability and mitigate the copper loss. First, this paper analyzes the fundamental principles of normal power generation in DSEG, establishes its mathematical model under excitation loss, and investigates the fault-tolerant control strategy. Subsequently, this paper analyzes the mechanism behind the high copper loss issue in implementing the positive and negative excitation angle control (PNEAC) strategy during the fault-tolerant operation of the DSEG under excitation loss. Furthermore, a positive and negative current given control (PNCGC) strategy with an advanced angle is proposed for FTPG, to optimize copper loss of DSEG under excitation loss. According to the mentioned hypothesis, some experiments are performed on an 18/12 pole DSEG system to demonstrate the feasibility and effectiveness of the proposed strategy.